    INTRODUCTION Thank you for purchasing Xytronic’s high heat capacity soldering station – the best solution for your soldering equipment needs especially for lead free applications! We believe that you will be more than satisfied with many features and the versatility of your new soldering station.
  • Page 3: Product Description

    ◆ EARTH JACK: With a grounding connector, there is the possibility for a grounding of the wire strap if required. PRODUCT DESCRIPTION LF-3000 electronically high frequency soldering station with specially intelligent chip microcomputer control designs was developed to meet the present and future Lead-free soldering needs of the electronic production industry and suitable for work on professional SMD electronics.
  • Page 4 The LF-3000 incorporates electronic circuitry which enables the user to alter tip temperature from 100 to520℃without changing tips or heating elements. Also, with digital display readout and pressing keys on the front panel get clear vision and comfortable setting. The temperature is maintained within +/-3℃ of its operating temperature by a thermocouple sensor placed in the head of the heating element, allowing the tip to rest against the sensor.
  • Page 5 Rear side ○ 8 AC Power cord in-let ○ 9 Fuse ○ 10 Earth Jack Fig. 1 Soldering iron introduction Heating element :With the high-frequency heating ,get the rapid heat up time and great Sensor: Ahead of the thermal recovery tip , greatly sense the temperature.
  • Page 6: Specifications

    SPECIFICATIONS: Model LF-3000 Input 220-240Vac 50Hz 100-120Vac 60Hz Output 36Vac/90W Fuse (Slow type) 100℃~520℃ Temperature Range Temperature Correction +99℃~-99℃ Range 100℃ No Password Default Set Temperature correction value“00” Degrees Centigrade 111x158x137mm(W x H x D) Figure Dimension Weight (Unit only) 2.5kg...
  • Page 7: Function Introduction

    To comply with safety standards, the power lead must only be replaced by authorized technicians as special purpose tools are required. DO NOT MODIFY THE LF-3000. Caution: Soldering irons operate at high temperatures and can easily burn people or objects.
  • Page 8 the user to input the mode lock password “010” (fixed). If the user inputs the same number as “010”, the unit will enter the modes selection procedure, otherwise, the unit will be back from the current mode automatically. 2. After the unit enters the Modes selection, the LED will display “F-0”and flash. Press “▲”or “▼”...
  • Page 9 setting “Sleep” mode. 6.Wake-up method ① Temperature Down Suspend: If the unit is set in Sleep mode function, after 20min idleness, the system will enter the sleep mode automatically, the temperature will go down to 100℃ and the LED displays at “ 100” and flashes. Activating the solder wand will disengage the suspend status and the unit will immediately ramp up to the preset temperature.
  • Page 10: Maintenance

    and thus will eat away the tip. 5. Never clean the tip with a file or abrasive materials. 6. Do not use fluxes which contain chloride or acid. Use only rosin or resin activated fluxes. 7. If an oxide film forms on the tip, it can be removed by careful buffing with a 600-800 grit emery cloth, isopropyl alcohol or equivalent and then wrapping rosin core solder around the newly exposed surfaces.
  • Page 11 INTERCHANGEABLE TIPS 1.6D 4.2D...