This equipment should be unpacked and handled with care. The original packaging is the safest container in which to transport the unit and can be used if returning the unit for service. The packaging contains: One (1) Arecont Vision MicroDome® G2 Camera • One (1) ceiling template •...
Page 4
VISION’s written authorization; (ii) has not been used in accordance with applicable documentation; (iii) has been subjected to unusual stress, neglect, misuse, abuse, improper storage, testing or connection; or unauthorized repair; or (iv) is no longer covered under the Warranty Period. ARECONT VISION MAKE NO WARRANTIES OR CONDITIONS, EXPRESS, IMPLIED, STATUTORY OR OTHERWISE,...
MicroDome®
G 2
Installation
M anual
Camera Overview The MicroDome® G2 megapixel IP cameras provide professional surveillance for a variety of network surveillance requirements. An innovative spring arm design makes recessed installation a snap: simply slide the camera through the hole and secure the magnetized cover ring with a single screw.
MicroDome®
G 2
Installation
M anual
In-ceiling (-F Model) Installation 1. Determine a secure location to mount the camera. Cut a hole in the ceiling using the template provided (3.25 inches in diameter) to fit the camera housing. 2.
Page 7
MicroDome®
G 2
Installation
M anual
4. Pull the network cable through the ceiling and plug it into the network connector on the camera housing (Note: this can be done at a later time if there is access to the network connector on the camera housing after installation into the ceiling).
Page 8
MicroDome®
G 2
Installation
M anual
NOTE: Ensure not to press the remote focus motor against the sides of camera module when adjusting the field of view (Figure 5). Figure 5: Remote focus motor 9.
Page 9
Captive Fastener Camera Housing 11. Use the Arecont Vision software AV IP Utility located on the CD or available for download at our website (www.arecontvision.com) for camera discovery and setup (see Instruction Manual located on the CD or available on our website).
MicroDome®
G 2
Installation
M anual
Changing the Lens 1. Remove the dome cover by loosening the captive fastener with the supplied Philips head screwdriver. Reference # Description Captive Fastener 2. Loosen the lens lock screws (3) using the supplied flat-head screwdriver (if necessary). Only do so if the lens seems very tight when turning.
MicroDome®
G 2
Installation
M anual
Optional: Removing the Bubble For best image quality in an indoor environment, the bubble can be easily removed. 1. For an in-ceiling “F” model camera, remove the dome cover by unscrewing the captive fastener. Set the camera aside.
MicroDome®
G 2
Installation
M anual
Optional: Connecting Digital I/O 1. To use digital I/O, connect digital I/O with pigtail cable connector as shown in the image. Output Input Electrical Characteristics Input Voltage (V) (Measured between + and –...
Page 13
MicroDome®
G 2
Installation
M anual
Digital I/O Orange Digital OUT + Yellow Digital OUT - White Digital IN + Black Digital IN - Table
2 Page | 13 support@arecontvision.com ...
Page 14
MicroDome®
G 2
Installation
M anual
Camera Power Up CAUTION! This product should be installed by a qualified service technician in accordance with the National Electrical Code (NEC 800 CEC Section 60) or applicable local code.
Page 15
MicroDome®
G 2
Installation
M anual
2. Connect the PoE switch to your computer’s network port using an Ethernet cable. NOTE: A yellow LED on the rear of the camera illuminates after a few seconds. The flashing yellow LED indicates that a link to your computer has been established.
AV IP Utility tool is efficient and convenient for mass or single camera uploads. The AV IP Utility tool is compatible with all Arecont Vision® megapixel cameras. The user manual for the software is included on the CD that came with your camera or available on our website.
2. Scroll to the Focus Tab section. ® NOTE: Additional information regarding the Arecont Vision web interface is found separately in the
A V IP Utility Web Browser Manual
v ia the Arecont Vision website. Page | 17 support@arecontvision.com ...
MicroDome®
G 2
Installation
M anual
3. Click the Full-range Focus button. The camera begins to autofocus with the lens stopping at the best overall point of focus. When the focus area turns to Green, the autofocus is complete. ...
Page 19
MicroDome®
G 2
Installation
M anual
5. Left click and drag to highlight the area within the zoomed window you created. 6. Click the focus menu, then the Short-Range Focus button. 7. The camera proceeds to go through the short range adjustment around the original focus. It stops at the best point of focus using the new reference area.
MicroDome®
G 2
Installation
M anual
Focus Tab Menu Feature Description Manual Focus: Numbers indicate the level of focusing in order to adjust the field-of-view. +20, +5, +1, - 20, -5, -1 To set-up a focus area (if necessary), draw a rectangle with the mouse (by left-clicking and dragging the mouse to a desired zoom size).
MicroDome®
G 2
Installation
M anual
In-Ceiling Mounting Template For best results, use 3.25" hole saw. 3.25" Diameter Revised 5.15 Page | 21 support@arecontvision.com ...
Swap the “troubled” camera with a known good camera to see if the problem follows the • camera or stays at the location. 3. Contact Arecont Vision Technical Support one of three ways: 1. Online Portal: Support.ArecontVision.com 2. Phone: 1.818.937.0700 (option #1) 3.
Need help?
Do you have a question about the AV1555DN-F and is the answer not in the manual?
Questions and answers