Make sure to investigate the code requirements to ensure compliance prior to
operating the compressor.
The owner, lessor, or operator of this compressor is hereby notified and forewarned
that any failure to observe these safety precautions may result in injury, death
and/or property damage.
Operating Instructions
This Instruction Manual is only part of the full Operations Manual that can be
found on the Kellogg-American website,
The operating instructions form part of the machine and must be made available
to the compressor operating personnel at all times. In order to receive the
maximum performance and long life from your compressor, the following
instructions should be carefully read and all points regarding installation and
operation of the unit should be noted and observed. Careful reading of the
manual, prior to connecting anything to the motor or compressor, will pay
dividends in long-term trouble-free operation.

Installation Instructions

Inspection:
Check for possible damage in transit and see that the pulley turns freely by hand.
Report any damage to delivering carrier at once.
Location:
Select a clean, dry, and lit location. In cold climates the compressor should be
installed in a heated building. Insulate cold water or other low temperature pipes
that pass overhead to avoid the possible collection and dripping of condensate
onto the compressor and motor, which could cause rusting and/or motor shorting.
Do not install compressor in a boiler room, paint spray room, or area where
Section III
sandblasting is carried on. If air in the area where the compressor is to be installed
is acid-laden or dust-laden the compressor intake should be piped to the outside.
This intake pipe should be increased one pipe size for every twenty (20) feet of
www.kellogg-american.com
Pump Operation Manual
4
.