Section 2. Unit Location Considerations

2.1 Unit Dimensions and Weight
Table 2.1
Unit Dimensions and Weight
Models
H x D x W (in)
A4HP4017A
28.6 x 23.6 x 23.6
A4HP4018A
28.6 x 25.6 x 25.6
A4HP4023A
28.6 x 25.6 x 25.6
A4HP4024A
28.6 x 29.8 x 29.8
A4HP4030A
28.6 x 34.3 x 34.3
A4HP4036A
28.6 x 34.3 x 34.3
A4HP4042A
28.6 x 34.3 x 34.3
A4HP4048A
32.6 x 34.3 x 34.3
A4HP4060A
44.6 x 34.3 x 34.3
* Weight values are estimated uncrated.
When mounting the outdoor unit on a roof, be
sure the roof will support the unit's weight.
Properly selected isolation is recommended to
alleviate sound or vibration transmission to the
building structure.
2.2 Service Valves Locations
1. The locations of the below listed valves in
the unit are shown in the figure.
a) Liquid line connection
b) Access valve for compressor suction
pressure measurement
c) Suction line connection
4
Weight* (lb)
142
143
143
159
177
177
197
210
252
Liquid Line Connection
Access valve for compressor
suction pressure measurement
W
H
D
Suction Line
Connection
88-A4HP4001-1B-EN