Specification - LG A2UW18GFA0 Service Manual

Multi air conditioner
Hide thumbs Also See for A2UW18GFA0:
Table of Contents

Advertisement

1. Specification

Testing Combination
Capacity
Power Input
EER
SEER / HSPF
Power Supply
Running Current
Starting Current
Wiring Connections
Combination
Casing Color
Dimensions
Net Weight
Compressor
Refrigerant
Refrigerant Oil
Heat Exchanger
Fan
Fan Motor
Sound Pressure Level
Sound Power Level
Piping Connections
Piping Length
Maximum Height Difference
Operation Range
(Outdoor Temperature)
Note:
1. All data are based on the following conditions:
- Cooling Temperature : Indoor 26.7°C(80°F) DB / 19.4°C(67°F) WB
Outdoor 35°C(95°F) DB / 23.9°C(75°F) WB
- Heating Temperature : Indoor 21.1°C(70°F) DB / 15.6°C(60°F) WB
Outdoor 8.3°C(47°F) DB / 6.1°C(43°F) WB
- Piping Length : Interconnected Pipe Length = 7.5m
- Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero.
Copyright ©2014 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Outdoor unit
Min.~Rated~Max.
Cooling
Min.~Rated~Max.
Min.~Rated~Max.
Heating
Min.~Rated~Max.
Cooling
Min.~Rated~Max.
Heating
Min.~Rated~Max.
Cooling
Min.~Rated~Max.
Heating
Min.~Rated~Max.
Cooling
Heating
Power Supply Cable (included Earth)
Power and Communication
Outdoor ~ BD unit No. x mm
Cable (included Earth)
Sum of Indoor Units Capacity
Number of Indoor Units
Number of BD Units
W x H x D
W x H x D
Type
Model
Motor type
Motor Output
Type
Precharged Amount
Chargeless-Pipe Length
Additional Charging Volume
Control
Type
Charged volume
(Row x Column x Fins per inch) x No.
Type
Air Flow Rate
Type
Output
Cooling
Heating
Cooling
Liquid
Outer Dia.
Gas
Outer Dia.
Total Piping
Main Piping
Total Branch Piping
Each Branch Piping
Outdoor Unit ~ Indoor Unit
Indoor Unit ~ Indoor Unit
Cooling
Min. ~ Max.
Heating
Min. ~ Max.
kW
Btu/h
kW
Btu/h
kW
kW
Btu/Wh
-
V , Ø , Hz
A
A
Max.
A
Max.
A
No. x mm
2
(AWG)
2
(AWG)
kBtu/h
EA
EA
-
mm
inch
kg (lbs)
-
Model x No.
-
W x No.
-
g (oz)
m (ft)
g/m (oz/ft)
-
-
cc x No.
-
-
m
3
/min x No.
W x No.
Rated
dB(A)
Rated
dB(A)
Rated
dB(A)
mm(inch) x No.
mm(inch) x No.
Max.
m (ft)
Max.
m (ft)
Max.
m (ft)
Max.
m (ft)
Max.
m (ft)
Max.
m (ft)
℃ DB (℉ DB)
℃ WB (℉ WB)
2. Wiring cable size must comply with the applicable local and national
code.
3. Due to our policy of innovation some specifications may be changed
without notification.
4. Sound Level Values are measured at Anechoic chamber.
Therefore, these values can be increased(maximum 3dB(A)) owing to
ambient conditions during opration.
*: This temperature(-20 ~ -10℃) can be operated only when Low
Ambient Kit is installed.
- 2 -
A2UW18GFA0
[LMU18CHV]
AMNW09GDBL1 * 2EA
5
17,000
6.5
22,000
1.31
2.04
13
22.0/9.7
208/230, 1, 60
5.9
9.2
-
-
3C x 2.5 (12)
-
24
2
-
Warm Gray
870 × 655 × 320
34-1/4 x 25-25/32 x 12-19/32
45 (99.2)
Twin Rotary
GKT176MA x 1
BLDC
1,500 (at 60Hz) x 1
R410A
1,800 (63.5)
15(49.2)
20 (0.22)
Electronic Expansion Valve
FVC68D
670 x 1
(2 x 28 x 14) x 1
Propeller
50 x 1
BLDC
85.4 x 1
50
52
62
Ø 6.35 (1/4) x 2
Ø 9.52 (3/8) x 2
50 (164.0)
-
-
25 (82.0)
15 (49.2)
7.5 (24.6)
-18(-0.4) *~ 48 (118.4)
-20 (-4.0) ~ 18 (64.4)
LGE Internal Use Only