Download Print this page

Advertisement

Quick Links

INDUSTRIAL LAUNDRY EQUIPMENT
A Division of East Coast Services
PO Box 1369 ∙ Hickory, NC 28603
125 lb.
Washer-Extractor
Model TCW-7055
Installation / Maintenance
Manual
Parts List
PO Box 1369
Hickory, NC 28603
We invite you to visit our website at
www.washtech.ws
or contact us directly.
Phone: 800-314-8081
Fax: 828-397-8615

Advertisement

loading
Need help?

Need help?

Do you have a question about the TCW-7055 and is the answer not in the manual?

Questions and answers

Summary of Contents for Washtech TCW-7055

  • Page 1 INDUSTRIAL LAUNDRY EQUIPMENT A Division of East Coast Services PO Box 1369 ∙ Hickory, NC 28603 125 lb. Washer-Extractor Model TCW-7055 Installation / Maintenance Manual Parts List PO Box 1369 Hickory, NC 28603 We invite you to visit our website at www.washtech.ws...
  • Page 6 -3-02-1...
  • Page 15: Front Assembly

    FRONT ASSEMBLY KEYPAD TOP VIEW) (RIGHT HAND SIDE) (LEFT HAND SIDE) -6-01-...
  • Page 23 MODEL: TCW-通用 Share 7. Machine Fault Display and Details Machine Fault Display and Details Corrective Indication Fault Display Description Refer to the Inverter default Fault 01 9.Inverter fault display and troubleshooting. 1. It doesn't include the 1. Don't set the warm warm water valve water level.
  • Page 25 MODEL: TCW-通用 Share 9. Inverter Fault Display If there is a fault associate with the inverter, then use the Table shown below for corrective action. Fault Display and Details Indication Fault Display Description Corrective Two seconds are counted after Uu 1 Undervoltage (PUV) detection of low voltage.
  • Page 26: Error Message And Troubleshooting

    9.2 Error Message and Troubleshooting ‧ (A) Protective Function LCD Display Fault Contact Fault Contents (English) Output Fault The main circuit DC voltage becomes lower than the low voltage Operation DC Volt. Low detection level (Cn-34). Fault The inverter output current becomes approx. 200% and above the Operation Over Current inverter rated current.
  • Page 27 Error Causes Action to Be Taken ‧ Power capacity is too small. ‧ Voltage drop due to wiring resistance. ‧ Check the source voltage and wiring. ‧ A motor of large capacity connected to the same power ‧ Check the power capacity and power system. system has been started.
  • Page 28 (B). Warning and Self-Diagnosis Functions LCD Display Fault Contact Fault Contents (English) Output (blinking) The main circuit DC voltage becomes lower than the lower Alarm No operation under-voltage level before the motor starts. DC Volt. Low (blinking) The main circuit DC voltage becomes higher than the lower Alarm No operation under-voltage level before the motor starts.
  • Page 29 Error Causes Action to Be Taken ‧ Measure the main circuit DC voltage, if the ‧ Input voltage drop voltage is lower allowance level, regulate the input voltage. ‧ Measure the main circuit DC voltage, if the ‧ Input voltage rise voltage is higher than allowance level, regulate the input voltage.