System Status Chirps

Action
Number of Chirps
Arm
1
Arm
1 (3 second delay), 1
Disarm
2
Disarm
4
Disarm
5

Table of Zones

Zone No.
Trigger type
1
Instant
2
Multiplexed
3
Instant Two-stage, or constant
4
Multiplexed Input
5
Two-stage (similar to doors)
6
Hood trigger
7
Multiplexed input (sensors)
NOTE: The Warn Away
38
Description
System armed
System armed with Bypass Notification
System disarmed
System disarmed with Tamper Alert
System disarmed NPC
Input description
H1/7 BLUE wire. Connect to optional hood/trunk
pins.
For the onboard shock sensor light impacts
will trigger a Warning Zone response, while
heavy impacts will instantly trigger the full alarm
sequence.
Door switch circuit. H1/8 GREEN or H1/6 VIOLET.
Inputs shorter than 0.8 seconds will trigger a
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
Ignition input. H1/4 YELLOW.
H2/2 GREY
Inputs shorter than 0.8 seconds will trigger a
Warning Zone response, while inputs longer than
0.8 seconds will instantly trigger the full alarm
sequence.
®
response does not report on the LED.
®