4. Total Assembly line process
4.1. Adjustment Preparation
▪ W/B Equipment condition
CA210
: CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)
LED -> CH14, Test signal: Inner pattern(80IRE)
▪ Above 5 minutes H/run in the inner pattern. ("power on" key
of Adjustment remote control)(Only EEFL)
X=0.269 (±0.002)
Cool
13,000 K
Y=0.273 (±0.002)
X=0.285 (±0.002)
Medium
9,300 K
Y=0.293 (±0.002)
X=0.313 (±0.002)
Warm
6,500 K
Y=0.329 (±0.002)
* White Balance table.
▪ Edge LED module change color coordinate because of
aging time
▪ Apply under the color coordinate table, for compensated
aging time
Cool
Aging
GP4
time
X
(Min)
269
1
0-2
280
2
3-5
279
3
6-9
277
4
10-19
276
5
20-35
274
6
36-49
272
7
50-79
271
8
80-119
270
9
Over 120
269
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON -> Enter
the mode of White-Balance, the pattern will come out.
Full White Pattern
RS-232C Communication
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
<Test Signal>
Inner pattern
(204gray, 80IRE)
Medium
Warm
y
x
y
x
273
285
293
313
287
296
307
320
285
295
305
319
284
293
304
317
283
292
303
316
280
290
300
314
277
288
297
312
275
287
295
311
274
286
294
310
273
285
293
309
CA-210
COLOR
ANALYZER
TYPE : CA-210
* Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 10 lux).
(2) Adhere closely the Color analyzer(CA210) to the module
less than 10 cm distance, keep it with the surface of the
Module and Color analyzer's prove vertically.(80° ~ 100°).
(3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using 'no signal' or 'POWER ONLY' or the others, check
the back light on.
▪ Auto adjustment Map(RS-232C)
RS-232C COMMAND
[CMD
ID
Wb
00
Wb
00
RS-232C COMMAND
[CMD ID DATA]
Cool
Mid
R Gain
jg
Ja
G Gain
jh
Jb
B Gain
ji
Jc
y
R Cut
329
G Cut
337
B Cut
335
334
<Caution>
333
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
330
adjust other two lower than C0.(When R/G/B Gain are all
327
C0, it is the FULL Dynamic Range of Module)
325
324
* Manual W/B process using adjust Remote control.
323
▪ After enter Service Mode by pushing "ADJ" key,
▪ Enter White Balance by pushing " ► " key at "9. White
Balance".
* After you finished all adjustments, Press "In-start" key and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model's module from factory Jig model.
* Push the "IN STOP" key after completing the function
inspection. And Mechanical Power Switch must be set
"ON".
- 11 -
DATA]
00
White Balance Start
ff
White Balance End
CENTER
(DEFAULT)
MIN
Warm
Cool
Mid
jd
00
172
192
je
00
172
192
jf
00
192
192
64
64
64
64
64
64
LGE Internal Use Only
MAX
Warm
192
192
192
192
172
192
64
128
64
128
64
128