DISCOVERY W
DISCOVERY W
DISCOVERY W
DISCOVERY W
Advanced Wireless PIR Motion Detector
1 1 1 1 . FEATURES
. FEATURES
. FEATURES
. FEATURES
The DISCOVERY W wireless PIR is an advanced microprocessor-
controlled, low-current PIR detector incorporating an on-board
miniature UHF transmitter.
Following detection, the DISCOVERY W activates the on-board
UHF transmitter for 2 seconds, then disarms itself to save battery
power. The detector rearms itself (reverts to the ready state)
automatically 2 minutes after the last movement has been
detected. A TEST/NORMAL selector is used to override the
2-minute rearm timer during walk testing.
A feature summary of the DISCOVERY W detector is given
below.
• • • •
Integral swivel bracket for wall or ceiling installation
• • • •
Sealed chamber protects the optical system
• • • •
On-board CE and FCC approved transmitter module
• • • •
9 Volt battery powered, with unique energy saving
circuitry
• • • •
Extremely-low current consumption – 0.013 mA
• • • •
Sends automatic low-battery and tamper alerts
• • • •
Programmable pulse counter (1, 2, 3 or 5 pulses)
• • • •
Two-position vertical adjustment
• • • •
White light protection
• • • •
Programmable 8-bit system code and 4-bit channel code

2. SPECIFICATIONS

OPTICAL
Detection
Pattern:
90°
angle lens with 38 beams in 3
detection layers. Max. coverage is
15 x 15 m (50 x 50 ft).
Adjustment: 2-position vertical
adjustment: FAR and NEAR.
ELECTRICAL
Voltage: 9 Volt alkaline or lithium
battery.
Standby Current: 0.013 mA.
LED: Walk Test & transmission.
Detector: Dual-element low-noise
pyroelectric sensor.
Pulse Counter: Programmable to
1, 2, 3 or 5 pulses with walk-test
override.
Rearm Timer: Rearms the unit
about 2 minutes after the last
alarm; the timer is disabled in the
walk test mode.
WIRELESS
Frequency (MHz): 315, 304, 404, 418, 433.92 or other
frequencies according to local requirements.
Alarm Transmission Duration: 2 seconds.
Encoding: 8-bit digital word, 256 combinations, pulse width
modulation.
Channels: 4 channels, switch selectable.
DE3580
wide
Figure 2. Coverage Pattern
Installation Instructions
• • • •
Surface and corner mounting
• • • •
Rejects RF interference up to 1000 MHz
• • • •
Elegantly styled, sturdy case
Keyhole-shaped slot for easy removal of PCB
Figure 1. The DISCOVERY W Wireless Detector
Battery Test: Automatic transmission of "Code 0" at 2-minute
intervals if the battery voltage drops below 7 V.
Tamper Alert: Transmission of the "Channel 2" code at 2-minute
intervals, until the tamper switch is restored.
ENVIRONMENTAL
Operating Temperature: -10°C to 50°C (14°F to 122°F).
Storage Temperature: -20° to 60°C (-4°F to 140°F).
RFI Protection: Greater than 30 V/m up to 1000 MHz.
Note: The temperature range may be reduced due to battery
characteristics.
Compliance with Standards: Meets Part 15 of the FCC rules;
also complies with Directive 1999/5/EC.
MOUNTING
Height: 2.0 to 2.6 m (6.5 to 8.5 ft)
Room Size: Up to 15 m (50 ft) in the "FAR" position
2 - 8 m (6 - 24 ft) in the NEAR position.
Installation Options:
Surface or corner (without bracket);
surface or ceiling (with bracket).
Bracket Adjustment: 20° downward, 20° left and right.
PHYSICAL
Dimensions (H x W x D): 117 x 65 x 47 mm
(4-5/8 x 2-9/16 x 1-7/8 in.).
Weight: 92 g (3.25 oz) without bracket, 107 g (3.8 oz) with bracket.
Color: White
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the discovery w and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Visonic discovery w

  • Page 1 2 minutes after the last movement has been detected. A TEST/NORMAL selector is used to override the 2-minute rearm timer during walk testing. A feature summary of the DISCOVERY W detector is given below. • • • • Integral swivel bracket for wall or ceiling installation •...
  • Page 2 3 3 3 3 . INSTALLATION . INSTALLATION . INSTALLATION . INSTALLATION 3.1 Installation Hints To minimize false alarms: Do not aim at heat sources Mount on solid, stable surfaces Do not expose to air drafts Do not install outdoors Prevent direct sunlight from Keep wiring away from reaching the detector...
  • Page 3 Figure 7. Tilt / Swivel Limits 3.4 Battery Installation The DISCOVERY W is powered by a 9-volt alkaline or lithium battery. Remove the detector's front cover, snap the battery clip onto the battery and place the battery in its place (below the printed circuit board).
  • Page 4 VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788 VISONIC INC. (U.S.A.): 10 NORTHWOOD DRIVE, BLOOMFIELD CT. 06002-1911. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094 VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 730-0800 FAX: (0870) 730-0801 www.visonic.com...

Table of Contents