Nitronic ST215 Operating Instructions Manual

High precision stripping machine
Hide thumbs Also See for ST215:

Advertisement

Quick Links

Nitronic AG
Mattenstrasse 11
Sdasdasdsdfdsdcdscsdcdcd
2555 Bruegg
Email:
cdcsc
Switzerland
Phone: +41 32 373 70 70
High precision stripping machine
Please read through these operating instructions carefully before starting work.
info@nitronic.ch
Operating instructions
ST215 / ST215W / Polystrip
V3.0 (based on V3.0 German)
1

Advertisement

Table of Contents
loading

Summary of Contents for Nitronic ST215

  • Page 1 Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Operating instructions High precision stripping machine ST215 / ST215W / Polystrip V3.0 (based on V3.0 German) Please read through these operating instructions carefully before starting work.
  • Page 2: Table Of Contents

    Table of Contents Table of Contents ............................2 Symbols ................................3 Product description ............................3 Centering unit (ST215 and ST215W) ......................3 Connecting the machine ..........................4 Control Elements ............................4 Placing in operation ............................. 5 Setting the centering unit........................5 Setting the Diameter ..........................
  • Page 3: Symbols

    The high processing quality paired with high-quality materials make the ST215 a robust production machine. The ST215 is a real all-rounder; it masters stripping of standard cables in short cycle times as well as micro-coaxial cables with highest precision. The absence of grippers allows the ST215 to process shortest cable ends, crushes on the outer jacket are excluded.
  • Page 4: Connecting The Machine

    Connect the machine with the supplied power supply unit to the mains supply and to the "24V DC"  connection. If the power plug is not compatible with your power outlet, please contact your Nitronic partner or contact us directly.
  • Page 5: Placing In Operation

    Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Placing in operation The sequence of the settings should be observed, since changes to the stripping diameter, due to the design, require adjustments to the stripping length! For adjustments on the stripping head, i.e.
  • Page 6: Setting The Wayback (St215W Only)

    Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Setting the Wayback (ST215W only) The Wayback is an opening of the blades before pulling off the jacket. This allows a slightly deeper cut without touching the conductor or shield during the pull-off.
  • Page 7: Setting The Rotation Duration / Incision Rate

    Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Setting the rotation duration / incision rate The rotation duration and the incision rate are selected with the same switch. The longer the setting of the rotation duration, the shorter the incision rate.
  • Page 8 Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Adjust machine Insert the cable end to the sensor Without foot pedal With foot pedal When the cable touches the Start the stripping cycle with...
  • Page 9: Maintenance

    Maintenance is limited to cleaning the stripping head. Lubrication The ST215 is designed so that no grease or oiling is required. In order to ensure good function and a long service life, no greasy or oily substances may get into the device!
  • Page 10 Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Insert the position retainer into the stripping head as shown in  Fig. by pushing the large Allen screw at the longitudinal scale to the rear. This makes it easier to insert ...
  • Page 11: Dismantling The Centering Unit

    Loosen screw (19) (black) and turn the centering scale (17) clockwise to diameter 2.0 mm. Retighten  screw (19) (black) and remove calibrating pin (30). The ST215 is now ready for use. Dismantling the centering unit Loosen screw (19) (black) and remove centering scale (17) with a slight turning movement Fig. 11.
  • Page 12: Assembling The Centering Device

    Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Push the two keys (22) out of the guides with a pair of tweezers and remove them Fig. 13. The guide plate (23), the centering jaws (25) and the helixes (26) can now be removed together Fig. 14.
  • Page 13 Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Screw on nut (18) and tighten up Fig. 17.  Fig. 17 Fig. 18 Insert the two keys (22) and install the previously-greased O-ring (20) Fig.
  • Page 14: Fit The Stripping Blades And Calibrating The Centering Unit

    Then by rotating the centering scale (17) close the centering jaws as far as the calibrating pin (30) Fig. Loosen screw (19) (black) and turn the centering scale (17) clockwise to diameter 2.0 mm. Retighten  carefully screw (19) (black) and remove calibrating pin (30). The ST215 is now ready for use.
  • Page 15: Error Sources

    Nitronic AG Mattenstrasse 11 Sdasdasdsdfdsdcdscsdcdcd 2555 Bruegg Email: info@nitronic.ch cdcsc Switzerland Phone: +41 32 373 70 70 Error sources Faults on cable Fault Diagnosis Fault rectification Inside conductor, screen or Cable is very eccentric Reduce centering diameter in dielectric cut into...
  • Page 16: Basic Equipment, Spare Parts, Options

    Phone: +41 32 373 70 70 Basic Equipment, Spare Parts, Options Basic Equipment ST215 Qty. Description Article Number Stripping machine ST215 / ST215 Inch 010083 / 010307 Stripping machine ST215W / ST215W Inch 010305 / 010314 Stripping machine Polystrip / Polystrip Inch 010520 / 010535...
  • Page 17: Options

    Weight 850g Stripping blades 4 pcs. Carbide, Titanium coated Power supply (Primary) 100-230 VAC, < 0.6A RMS, 47-63 Hz Power supply ST215 (Secondary) 24 VDC Compressed air 5 to max.8 Bar Outer hose diameter 6mm (0.24“) We reserve the right to make technical changes at any time!