Download Print this page
Optex V2 Series Instruction Manual

Optex V2 Series Instruction Manual

Photoelectric sensor

Advertisement

Quick Links

Photoelectric Sensor
AC/DC:Relay output
DC:Transistor output
V2 SERIES
・V2T-7000□□□
・V2R-1200□□□
・BGS-2V□□□□
INSTRUCTION
MANUAL
◦Confirm if the item meets your needs.
◦Before the use, you should first thoroughly read
this manual and operate correctly as mentioned.
◦You should keep this manual at hand for proper
use.
Protection
Protection
◦Adjusting the optical axias.
◦Through-beam type
1. Install the emitter and the receiver opposite to
each other so that the optical axis lines up.
2. Swing the emitter and the receiver vertically
and from side to side, and fix each at the mid-
point in the range where the indicating lamp at
the receiver lights up.
◦Reflection type
Swing the sensor vertically and from side to side,
an and fix it at the mid-point In the renge where
the indicating lamp lights up.
V2 series
※Through beam 54
 Retro‑reflection 29
 BGS 54
Output indicator(Orange)
Stable indicator(Green)
M4 Screw
Bracket
Through
beam
Cable type
V2T-7000
Connecotor type
Detecting distance
70m
Light source
Supply voltage
DC24~240V±10% AC24~240V±10% 50/60Hz
3VA max.(class A)
Current consumption
4VA max.(class B)
Response time
Hysteresis
Control output
Relay 1C DC30V 2A / AC250V 3A max.
Operation mode
Sensitivity ajustment
Indicator
Ambient temp./humidity
Storage temp./humidity
Environmental illuminance
Protection category/material
※ 1.Reflector V-61
24〜240V DC   24〜240V AC
Brown ①
10〜30V DC
+V Light ON
0V Dark ON
White ②
Black ④
Control output
Blue ③
0V
Brown ①
10〜30V DC
Black ④
Control output
No.①~④ corresponds to pin
○ 
+V Light ON
No. of connector
0V Dark ON
White ②
Blue ③
0V
◦Adjusting the sensitivity control
1. S e t t h e d e t e c t a b l e
object at the detection
position and turn the
s e n s i t i v i t y c o n t r o l
slowly from MIN toward
MAX until the output
indicator(orange) lights
up. Call it position A.
2. R e m o v e d e t e c t a b l e
o b j e c t a n d t u r n t h e
s e n s i t i v i t y c o n t r o l
from MAX toward MIN
p o s i t i o n w h e r e t h e
output indicator(orange)
is extinguished. Call it position B.
3. Point C midway between A and B is the
optimum sensitivity position.
45
20
5.5
Sens. adjustor
20
43.9
2m cable φ6.3(AC/DC)φ3.8(DC)
V2 series AC/DC type
BGS
Retro-reflection
(polarized filter)
Long range Middle range Short range
V2R-1200
BGS-2V100 BGS-2V50 BGS-2V30 V2T-7000D(N,P) V2R-1200D(N,P) BGS-2V100(N,P) BGS-2V50(N,P) BGS-2V30(N,P)
0.01~12m※1 25~100cm 15~50cm 10~30cm
2VA max. (class A)
2.5VA max. (class B)
15ms max.
20% max.
5% max.
Light ON
Output indicator (orange LED) / Stable indicator (green LED)  
               -25~55℃ / 35~85%RH (No condensation or freezing)
Sun light: 10000lx max.  Incandescent light: 3000lx max.
IP67 (IEC 144)/Case: ABS ( Glass fiber include)  Front cover: PC (PMMA for retro-ref. type)
V2 series
10〜30V DC
M12 Connector
◦Other precautions
○ It is dangerous to wire or attach/remove the
connector with the power on.Make sure to turn
off the power before operation.
○ Be careful not to install the sensor at the
following locations, for it may otherwise
malfunction:
• Where a lot of dust, vapor, or the like is preset
• Where corrosive gases are produced
• Where water, oil or the like flies directly onto
the sensor.
• Where strong vibration or shock is caused to
the sensor.
○ The product is not designed for outdoor use.
○ Do not use the sensor in a transient state at
power on.(about 150 ms)
C 
○ Avoid wiring together with high voltage or motor
line in order to prevent the sensor from noise.
○ The performance may depend on the individual
units or the condition of detected product.
○ T h i s p r o d u c t i s n o t a n e x p l o s i o n - p r o o f
construction. Do not use the product under
flamemable,explosive gas or detected product.
○ Do not use the product in water.
○ Do not disassemble,repair,or convert the
p r o d u c t . F a i l u r e t o d o t h i s m a y c a u s e
failure,fire,or electric shock.
○ Operate within the rated range.
This product cannot be use as a
safety device to protect human body.
70
23.7
Only DC type
M12 connector
V2 series DC type
Through
Retro-reflection
beam
(polarized filter)
Long range
V2T-7000CD(N,P) V2R-1200CD(N,P) BGS-2V100C(N,P) BGS-2V50C(N,P) BGS-2V30C(N,P)
70m
0.01~12m※1
25~100cm
Red LED
DC10~30V Including ripple (P-P) 10%
35mA max.
0.5ms max.
3ms max.
15% max.
NPN/PNP open collector DC30V 100mA max.(Residual voltage 1.8V max)
Light ON / Dark ON selectable by wiring
2 rotation volume
-40~70℃ / 35~95%RH
Pin No.
①DC10〜30V
 Connect to +V Light ON
 Connect to 0V Dark ON
③0V
④Control output
◦ Specifications and equipment are subject to
change without any obligations on the part of
manufacture.
◦ For more information, questions and comments
regarding products, please contact us below.
Manufactured and sold by:
600-8815 Kyoto, Shimogyo, Awata Chudoji 91, Japan
TEL.+81-(0)75-325-2920
FAX.+81-(0)75-325-2921
Website : http://www.optex-fa.com
BGS
Middle range
Short range
15~50cm
10~30cm
2ms max.
5% max.
OPTEX FA CO.,LTD.

Advertisement

loading

This manual is also suitable for: