Pyronix PCX-EXT-W/BK Quick Start Manual

Pyronix PCX-EXT-W/BK Quick Start Manual

External proximity tag reader

Advertisement

Quick Links

PCX-EXT-W/BK
External Proximity Tag Reader
EN50131-3:2009
EN50131-1:2006+A1:2009
PD6662:2010
Security Grade 3
Environmental Class IV
E N G L I S H
Installation Notes
NOTE: The reader module can be mounted on typical building materials; such
as wood, PVC, brick or metal etc. If you do encounter any problems with
different surfaces, please contact customer.support@pyronix.com
References:
Black: D1-. Red: D2+. Yellow: D3. Blue: D4.
Brown(1), Orange(2), Green(3): Used for addressing. Light Blue: Lock Relay.
Pink: Request to Exit. White, Grey: Door Monitoring. Purple: Door Alarm Monitoring
INSTALL KEYPADS/READERS (Programming Menu Required). Use the
brown, orange and green wires to address the Reader.
Connecting a Mag Lock: Use the light blue wire. The diagram show the
relay mag lock control switching positive.
Connecting a Request to Exit: Use the pink wire. The diagram shows a
normally open request to exit button, and takes "0V" from the control
panel.
Connecting Door Monitoring: Use the white and grey wire. The door
monitor input needs to be programmed as the first input number of the
reader address (programmed as "Entry Delay"). If the door contact is
forced open without presenting a valid tag or pressing the push to exit
button, then the panel will go into an alarm. NOTE: The DEOL values
must be 4K7, 2K2 as shown. This does not affect the control panel DEOL
values.
Connecting Door Alarm Monitoring: Use the purple wire. When the door
monitor exceeds the door open time or if the door is forced open then
the alarm PGM will generate an alarm. The input at the control panel
should be programmed as "24 Hour" or "Day Alarm" and the attribute
programmed as "Normally Open".
Lock Open Time: This is the time the door release is going to be active
when a valid tag is presented.
Door Open Time: This is the time the door is allowed to be open before
triggering an alarm.
The External Prox Reader
Specification
Supply voltage: 9-15VDC
Current consumption: Max 22mA
Input status when reader is Arm/Disarm or Sub-Area Control:
Input: Programmable
Input EOL resistor value: DEOL or SEOL. Alarm=4K7 / Tamper=2K2
Input status when reader is used as Access or Door Entry Control:
Input: Programmable
Input Function: Door monitor feature. Door opening time limit is programmable from
the Engineer menu.
Input DEOL resistors: NC
Input 2: Not programmable
Output 1: Not programmable. Activates the Door Lock Relay
Output 2: Not programmable. Door monitor alarm activation (forced or open for longer
than programmed time).
Output 1/2 Normal state: Floating
Output 1/2 Active state: 0V
Colour and Casing: 3mm ABS (Black: PCX-EXT-BK, White: PCX-EXT-W)
Temperature: Storage:-10°C to 50°C
Certified: -10°C to 40°C
Nominal: -25°C to 60°C
Dimensions (H x W x D): 85 x 85 x 21mm
IP65 Rated
If the control panel fails to arm, this is indicated by a broken tone on the external
proximity reader and the red LED will not illuminate. If this occurs, please check the
information at the nearest keypad.
Note: Access control falls outside the scope of EN 50131
Warranty
This product is sold subject to our standard warranty conditions and is warranted
against defects in workmanship for a period of two years (batteries excluded). In the
interest of continuing care and design, Pyronix Ltd reserves the right to amend
specifications, without giving prior notice.
Product Warning Information
For electrical products sold within the European Community. At the end of the
electrical products life, it should not be disposed of with household waste. Please
recycle where facilities exist. Check with your Local Authority or retailer for recycling
advice in your country.
Compatible Products
The PCX-EXT-W/BK can be connected to the following control panels/devices:
PCX 46, PCX 76i, 162i, 280i,IP and Enforcer 32-WE.
Each control panel/device connects via the RS485 bus terminals: D1-,D2+,D3,D4
NOTE: For information about programming tags to the external reader, please see
the control panel user manual.
 0845 6434 999 (UK). +44(0)1709 535 225
START
D1-
ATE INPUTS
D2+
D3
D4
D1- D2+ D3
D4
PCX
PCX-LCD/EX
ATE INPUTS
12V Lock
Relay
AUX
PCX
.
>5s
<10s
 customer.support@pyronix.com
 www.pyronix.com
RS485 BUS: 1km
D1-
D1-
D2+
D2+
D3
D3
D4
D4
PCX-ROX8R8T
PCX-RIX8i
PCX-RIX8+
D1- D2+ D3
D4
D1- D2+ D3
PCX-EXT-W
PCX-PROX/INT
4
K
7
Door Monitoring
Magnetic Contact
>10s
5s
EXIT TIMER
Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK
D1-
D2+
D3
D4
RS485 BUS: 1km
D1-
D2+
D3
D4
PCX-RIX8+/PSU
PCX-ROX16R+/PSU
D4
D1- D2+ D3
D4
PCX-RIX32-WE
ATE INPUTS
2
K
2
PCX
>5s
5s
5s
<10s
Brown(1):
Reader
Orange(2):
Addressing
Wires
Green(3):
Light Blue: Lock Relay
Pink: Request to Exit
White:
Door Monitoring
Grey:
Purple: Door Alarm Monitoring
INSTALL KEYPADS/
READERS?
Device Address?
0
Device Type?
Reader
[1]
Device Arm Area?
[A
]
Device Disarms?
[A
]
ID1
Device In Area?
0V (D1-)
ID2
[A
]
0V (D1-)
Reader is:
ID3
Entry Control[4]
0V (D1-)
ID4
Lock Open Time
0V (D1-)
[005]
ID5
0V (D1-)
Door Open Time
ID6
[010]
0V (D1-)
ID7
Door Name?
0V (D1-)
Enter Number:
Device 1
OFFICE
>10s
>5s
END
RINS1632-1

Advertisement

loading

Summary of Contents for Pyronix PCX-EXT-W/BK

  • Page 1 This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a period of two years (batteries excluded). In the interest of continuing care and design, Pyronix Ltd reserves the right to amend specifications, without giving prior notice.
  • Page 2 Ogni pannello / dispositivo di controllo si collega tramite morsetti del bus RS485: + D1-, D2, D3, D4 PCX-EXT-W/BK może być podłączony do następujących central: PCX 46, PCX 76i, 162i, 280i,IP i MEGJ.: Kártyák olvasóra programozásához lásd a vezérlőpanel leírását.