Page 1
Operation Operation Record of Changes Revision ECO Description Date Initiated By Preliminary Release 04/02/2002 A.L. Crozier, Jr. 9869 Original Release 06/05/2002 A.L. Crozier, Jr. 10033 Update to reflect amplifier improvement 08/05/2002 A.L. Crozier, Jr. 12707 Add German Translation 12/03/2004 A.L. Crozier, Jr. 13557 Add 2nd Generation PS Information 11/21/2005 S.
Operation Operation Description This chapter contains AC Power information for two power supplies: Generation 1 (Enable Switch). Part Number 310-0415-002 Outline Drawing 304-0215-004 Generation 2 (Circuit Breaker). Part Number 310-0415-004 Outline Drawing 304-0215-007 An external control and monitor unit may be used to operate the SSPA ODU series amplifiers.
Operation Power Supply Voltage Fault The power supply voltage fault circuit will latch immediately when a fault in one of the three internal power supply voltages occurs. A voltage fault may be cleared by sending the Fault Reset command. SSPA Overtemperature Fault A SSPA over-temperature fault will clear itself once the temperature of the base plate is reduced to a safe operating level.
Operation Control and Status Signals Control Signals AC Power ON Generation 1 Power Supply Normal (M&C Interface) The SSPA is turned on by connecting the AC Cord to the prime AC power source. ON/OFF control of the AC input is at the AC power source.
Operation Initial Turn On The Initial Turn On procedure has three parts: Prepower Check. • Turn On. • Turn Off. • This procedure should be followed to ensure proper operation of the amplifier and to avoid permanent damage to the amplifier. Caution Ensure that all of the following instructions are followed.
Operation Vorsicht Überschreiten Sie nicht die in der Produktspezifikation angegebene Begrenzung der HF-Eingangsspannung. Sie verursachen sonst eine Überhitzung der SSPA. Nichtbeachtung kann zu einer bleibenden Schädigung der SSPA führen. Turn On 1 There are two ways to turn ON the SSPA: Normal (M&C) Interface) —...
Page 8
Operation it will turn ON and be in the same state as it was when you turned it off. Generation 2 Power Supply The SSPA is switched off by turning OFF the prime AC power using the circuit breaker . If you turn the system OFF it will turn ON and be in the same state as it was when you turned it off.