Download Print this page
ProFlo PF1705 Installation Instructions Manual

ProFlo PF1705 Installation Instructions Manual

Wall hung back outlet gravity tank

Advertisement

Available languages

Available languages

Quick Links

Installation Instructions
Wall Hung Back Outlet
Gravity Tank
PF1705 / 1710 /
PF1705HE / PF1710HE
5
CAUTION
Note: The back-up nuts, also referred to as the
bearing nuts, must be set to take the full loading
PRODUCT IS FRAGILE
from the fixture while allowing a 1/6" clearance
Handle with care to avoid
between the fixture and the finished wall.
breakage and possible injury
Follow the carrier manufacturer's recommendation
settings for the outlet connection.
(A) Regular Screwdriver
(B) Adjustable Wrench
When setting fixture onto the carrier, it is not
A
(C) Marker
recommended to use a wax ring, felt or neoprene
For installations where consideration
(D) Tape Measure
(E) Level
are recommended.
is given for ADA compliance, the seat
(F) Silicone Sealant
height must be 17" to 19" (432mm
(G) Putty Knife
When setting the fixture to the carrier, the waste
(H) Flexible Supply Tube (Not Included)
483mm) from the finished floor.
gasket must be compressed sufficiently to assure
(I) Closet Carrier/Support (Not Included)
a positive gas and watertight seal.
CAUTION: PRODUCT IS FRAGILE
Handle with care to avoid breakage and possible injury!
For installations where consideration is given for
Installation
7
Install the fiber washer and cap nut onto the mounting
ADA compliance, the seat height must be 17" to
stud #2, hand tighten until the nut and washer are
19" (432 to 483) from the finished floor.
1. For typical installation of the wall hung back outlet fixture, a
touching the china. Hand snug firmly the cap nut against
4-bolt Carrier/Support system, (not supplied with this unit)
Wall Hung Back Outlet Toilet with Tank Installation
the china, this is all that is necessary for mounting the
SINK INSTALLATION:
must be used for attaching the water closet to the carrier/
cap nut and washer to stud #2.
1
support system and waste drain. Refer to the Installation
For typical installation of the wall hung back outlet fixture, a
.
4-bolt Carrier/Support system, (not supplied with this unit)
Instructions that were supplied with the Closet Carrier/
must be used for attaching the water closet to the carrier/support
Caulk sealant into the gap between the toilet and the
Support System for installation of the unit.
system and waste drain. Refer to the Installation Instructions
finished wall.
that were supplied with the Closet Carrier/Support System for
Tools & Materials
installation of the unit.
9" (228mm)
G
E
I
H
F
Note: If you wrench tighten the cap nut on mounting
stud #2 you will break the china since there is no
ble injury!
back nut on this stud.
Note: Views in this illustrations are for general representation
and may not necessarily define the exact contours of the product.
9
If replacing an existing toilet be certain to shut off
Front View
water supply before removing old toilet.
Fit the tapered side of the large rubber gasket into the
3
inlet opening of the bowl. The tank should sit level and
2. If you are installing the toilet on an existing support system,
lation
Mounting studs should extend 2-1/8" (54mm) beyond the
finished wall.
make sure the system is in compliance with local code
parallel to the finished wall.
2
If you are installing the toilet on an existing support system,
requirements and the support system is weight rated for
The waste horn should extend 5/16" (8mm) beyond the
make sure the system is in compliance with local code
the application requirements.
finished wall.
pport
Place the small rubber gaskets onto the tank mounting
requirements and the support system is weight rated for
s
the application requirements.
bolts that were supplied with your tank. Slide both bolts
r
into the mounting holes from inside the tank.
Secure the tank by placing the metal washer and nut
onto the bottom of the tank bolts and tighten by hand
both nuts while holding the tank level.
Top View of Carrier
Finished Wall
With the tank level and sitting parallel to the wall, begin
to tight the nuts alternating between the two nuts to
2-1/8"
keep the tank even. Tighten the nuts until the tank is
(54mm)
Cut Away of Mounting Hardware
snug against the sanitary tank bar on the bowl.
4
e
Place back up nuts supplied with the carrier/support on mounting
stud #1, #3 and #4. No back-up nut is used on mounting
CAUTION: PRODUCT IS FRAGILE
stud #2! Adjust the two lower back-up nuts so the front face of
the nuts are 1/16" away from the finished wall. Using a level,
Do not over tighten nuts more than a snug fit.
adjust the back-up nut on mounting stud #1 to a vertical plane
with mounting stud #3. Place back-up washer on the three
installed back-up nuts.
© 2013 Ferguson Enterprises, Inc.
Note; If the wall is irregular, the three back-up nuts and
When performance matters.
washers must be positioned to allow a minimum of 1/16"
gap between the fixture and the wall.
(H) Flexible Supply Tube (Not Included)
(I) Closet Carrier/Support (Not Included)
SINK INSTALLATION:
1
3. Mounting studs should extend 2-1/8" (54mm) beyond the
3
finished wall. The waste horn should extend 5/16" (8mm)
beyond the finished wall.
Recommended Tools & Materials
E
B
C
4. Place back up nuts supplied with the carrier/support on
F
mounting stud #1, #3 and #4. No back-up nut is used on
D
mounting stud #2! Adjust the two lower back-up nuts so
the front face of the nuts are 1/16" away from the finished
wall. Using a level, adjust the back-up nut on mounting
stud #1 to a vertical plane with mounting stud #3. Place
back-up washer on the three installed back-up nuts.
Note: If wall is irregular, the three back-up nuts and
washers must be positioned to allow a minimum of 1/16"
2
gap between the fixture and the wall.
When performance matters.
5. Note: The back-up nuts, also referred to as the bearing
nuts, must be set to take the full loading from the fixture
while allowing a 1/6" clearance between the fixture
and the finished wall. Follow the carrier manufacturer's
4
recommendation settings for the outlet connection. When
setting fixture onto the carrier, it is not recommended to
use a wax ring, felt or neoprene are recommended. When
setting the fixture to the carrier, the waste gasket must
be compressed sufficiently to assure a positive gas and
watertight seal.
6. Using two people, install the bowl onto the fixture mounting
Mounting
Studs
studs. Place the fiber washer supplied with the carrier/
support on mounting studs #1, #3 and #4. (Do not place
Back-Up Nut
a fiber washer or cap nut on mounting stud #2 at this
Back-Up
Washer
time.) Place the cap nut supplied with the carrier/support
Fiber
on mounting studs #1, #3 and #4. While holding the bowl
Washer
level and using an adjustable wrench, tighten the three cap
Cap Nut
nuts until they are snug. CAUTION: PRODUCT IS FRAGILE
5/16"
Do not over tighten nuts more than a snug fit.
(8mm)
Distributed Exclusively by Ferguson and Wolseley Canada
-1-
CAUTION: PRODUCT IS FRAGILE
Handle with care to avoid breakage and possible injury!
For installations where consideration is given for
ADA compliance, the seat height must be 17" to
19" (432 to 483) from the finished floor.
Wall Hung Back Outlet Toilet with Tank Installation
For typical installation of the wall hung back outlet fixture, a
4-bolt Carrier/Support system, (not supplied with this unit)
must be used for attaching the water closet to the carrier/support
system and waste drain. Refer to the Installation Instructions
that were supplied with the Closet Carrier/Support System for
installation of the unit.
9" (228mm)
Front View
Mounting studs should extend 2-1/8" (54mm) beyond the
6
Using two people, install the bowl onto the fixture mounting
finished wall.
studs.
The waste horn should extend 5/16" (8mm) beyond the
finished wall.
Place the fiber washer supplied with the carrier/support on
mounting studs #1, #3 and #4. (Do not place a fiber
washer or cap nut on mounting stud #2 at this time.)
Place the cap nut supplied with the carrier/support on
mounting studs #1, #3 and #4. While holding the bowl
Finished Wall
level and using an adjustable wrench, tighten the three
G
2-1/8"
cap nuts until they are snug.
I
(54mm)
5/16"
(8mm)
CAUTION: PRODUCT IS FRAGILE
H
Do not over tighten nuts more than a snug fit.
Note: Views in this illustrations are for general representation
When performance matters.
and may not necessarily define the exact contours of the product.
8
With the tapered side of the large rubber gasket facing
If replacing an existing toilet be certain to shut off
away from the tank, slip the rubber gasket over the
water supply before removing old toilet.
thread of the flushvalve on the bottom of the tank.
Connect the flexible water supply tube (Not Included)
If you are installing the toilet on an existing support system,
onto the fill valve of the tank.
make sure the system is in compliance with local code
requirements and the support system is weight rated for
the application requirements.
Set the tank onto the bowl,
with the tapered side of the
large rubber gasket towards
the bowl. While lowering the
tank onto the bowl, route
the flexible supply tube
through the opening provided.
Top View of Carrier
10
Cut Away of Mounting Hardware
Connect the flexible water supply line from the tank to
the shutoff valve. Tighten all coupling nuts securely.
Place back up nuts supplied with the carrier/support on mounting
stud #1, #3 and #4. No back-up nut is used on mounting
stud #2! Adjust the two lower back-up nuts so the front face of
Turn on water at the supply valve and allow the tank to fill.
the nuts are 1/16" away from the finished wall. Using a level,
adjust the back-up nut on mounting stud #1 to a vertical plane
Check all fittings for leakage and tighten any fittings that
with mounting stud #3. Place back-up washer on the three
installed back-up nuts.
are leaking.
Note; If the wall is irregular, the three back-up nuts and
washers must be positioned to allow a minimum of 1/16"
gap between the fixture and the wall.
Mounting Studs #1
Waste Drain
Mounting Studs #3
WARNING: Do not use plumbers putty, pipe dope or any other sealant on the
water supply connections to this tank.
WARRANTY
is void if any type of sealant is used on the water supply connection.
F
D
Note: Views in this illustrations are for general representation
and may not necessarily define the exact contours of the product.
If replacing an existing toilet be certain to shut off
water supply before removing old toilet.
5
Note: The back-up nuts, also referred to as the
2
bearing nuts, must be set to take the full loading
If you are installing the toilet on an existing support system,
make sure the system is in compliance with local code
from the fixture while allowing a 1/6" clearance
requirements and the support system is weight rated for
between the fixture and the finished wall.
the application requirements.
Follow the carrier manufacturer's recommendation
settings for the outlet connection.
When setting fixture onto the carrier, it is not
recommended to use a wax ring, felt or neoprene
Top View of Carrier
are recommended.
When setting the fixture to the carrier, the waste
gasket must be compressed sufficiently to assure
7. Install the fiber washer and cap nut onto the mounting stud
4
a positive gas and watertight seal.
Place back up nuts supplied with the carrier/support on mounting
#2, hand tighten until the nut and washer are touching
stud #1, #3 and #4. No back-up nut is used on mounting
stud #2! Adjust the two lower back-up nuts so the front face of
the china. Hand snug firmly the cap nut against the china,
the nuts are 1/16" away from the finished wall. Using a level,
this is all that is necessary for mounting the cap nut and
7
Install the fiber washer and cap nut onto the mounting
adjust the back-up nut on mounting stud #1 to a vertical plane
with mounting stud #3. Place back-up washer on the three
washer to stud #2. Caulk sealant into the gap between the
stud #2, hand tighten until the nut and washer are
installed back-up nuts.
Note; If the wall is irregular, the three back-up nuts and
toilet and the finished wall.
touching the china. Hand snug firmly the cap nut agains
washers must be positioned to allow a minimum of 1/16"
the china, this is all that is necessary for mounting the
gap between the fixture and the wall.
Note: If you wrench tighten the cap nut on mounting stud
cap nut and washer to stud #2.
#2 you will break the china since there is no back nut on
.
Mounting Studs #1
this stud.
Caulk sealant into the gap between the toilet and the
When performance matters.
finished wall.
Mounting Studs #3
-1-
Note: If you wrench tighten the cap nut on mounting
8. With the tapered side of the large rubber gasket facing
stud #2 you will break the china since there is no
away from the tank, slip the rubber gasket over the thread
back nut on this stud.
of the flush valve on the bottom of the tank. Connect the
9
flexible water supply tube (Not Included) onto the fill valve
Fit the tapered side of the large rubber gasket into the
of the tank. Set the tank onto the bowl, with the tapered
inlet opening of the bowl. The tank should sit level and
side of the large rubber gasket towards the bowl. While
parallel to the finished wall.
lowering the tank onto the bowl, route the flexible supply
tube through the opening provided.
Place the small rubber gaskets onto the tank mounting
bolts that were supplied with your tank. Slide both bolts
into the mounting holes from inside the tank.
Water
Secure the tank by placing the metal washer and nut
Mounting
Supply
onto the bottom of the tank bolts and tighten by hand
Studs
Opening
both nuts while holding the tank level.
Back-Up Nut
Back-Up
Tank
With the tank level and sitting parallel to the wall, begin
Washer
Washers
to tight the nuts alternating between the two nuts to
Fiber
keep the tank even. Tighten the nuts until the tank is
Washer
Cap Nut
snug against the sanitary tank bar on the bowl.
9. Fit the tapered side of the large rubber gasket into the
inlet opening of the bowl. Place the small rubber gaskets
CAUTION: PRODUCT IS FRAGILE
onto the tank mounting bolts that were supplied with your
Do not over tighten nuts more than a snug fit.
tank. Place the metal washer and nut onto the bottom of
the tank bolts and tighten the nuts until the tank is snug
against the sanitary tank bar on the bowl.Connect the
supply line from the tank to the shutoff valve and tighten
all coupling nuts securely. Turn on water supply and allow
the tank to fill. Check for leaks and tighten fittings as
necessary.
Finished Wall View
Note: Views in this illustration are for general representation
Mounting Studs #2
and may not necessarily define the exact contours of the
product.
When performance matters.
Mounting Studs #4
7730/7730HE
REV 10/2013
®
Mounting
Studs
Back-Up Nut
Back-Up
Washer
Fiber
Washer
Cap Nut
Cut Away of Mounting Hardware
Finished Wall View
Mounting Studs #2
Waste Drain
Mounting Studs #4
7730/7730HE
REV 10/2013
Tank
Bolts
Rubber
Gasket
Tank Nuts
18218 11/13

Advertisement

loading

Summary of Contents for ProFlo PF1705

  • Page 1 fixture and the finished wall. the application requirements. that were supplied with the Closet Carrier/Support System for installation of the unit. PF1705 / 1710 / 9” (228mm) Follow the carrier manufacturer’s recommendation settings for the outlet connection. Mounting...
  • Page 2: Troubleshooting

    Troubleshooting Wall Hung Back Outlet Wall Hung Back Outlet ® Gravity Tank Gravity Tank PF1705 / 1710 / PF1705HE / PF1710HE PF1705 / 1710 Difficulties These parts must be used as illustrated to ensure a water tight connection Difficulties Reason...
  • Page 3: Entretien Et Maintenance

    5. Utiliser un joint de feutre ou de caoutchouc (il n’est pas PROFLO est une marque déposée de Ferguson Ne pas utiliser de poudre abrasive ou de nettoyeur liquide recommandé d’utiliser un anneau de cire) sur la sortie Enterprises, Inc.
  • Page 4: Dépannage

    Dépannage Dépannage Réservoir de gravité Réservoir de gravité à ® à sortie arrière de type mural sortie arrière de type mural PF1705 / 1710 / PF1705HE / PF1710HE PF1705 / 1710 Dépannage Difficultés Raisons Solution Ces pièces doivent être utilisées telles qu’illustrées pour assurer une connexion d’eau étanche.
  • Page 5 Find a Location e ingrese su dirección en el campo location. de cambio del agua. sanitario. PROFLO es una marca comercial registrada de Ferguson Enterprises, Inc. LÍMITACIONES DE LA GARANTÍA Cuidado y mantenimiento 5. Use una empaquetadura de fieltro o goma, (no se IMPLÍCITA Y EXENCIÓN DE RESPONSABILIDAD DE DAÑOS...
  • Page 6: Solución De Problemas

    Tanque de gravedad de descarga ® trasera para colgar en pared trasera para colgar en pared PF1705 / 1710 / PF1705 / 1710 PF1705HE / PF1710HE Solución de problemas Estas partes deben usarse conforme se ilustra para garantizar una conexión de sellado hermético...

This manual is also suitable for:

1710Pf1705hePf1710he