RF Interlink Baseplate User Guide
Model 6000WB
Wireless RF interlink baseplate for
LIFESAVER 6000 series Smoke Alarms.
You do NOT need a home wi-fi system
to use these units. Multiple wireless units
create their own independent wireless RF
interlink network.
1
Part No: LIF6000WB
1208-7208-00

Advertisement

Table of Contents
loading

Summary of Contents for PSA LIFESAVER 6000WB

  • Page 1 RF Interlink Baseplate User Guide Model 6000WB Wireless RF interlink baseplate for LIFESAVER 6000 series Smoke Alarms. You do NOT need a home wi-fi system to use these units. Multiple wireless units create their own independent wireless RF interlink network. Part No: LIF6000WB 1208-7208-00...
  • Page 2 Teach children how to respond to the alarm and that they should never play with the unit. Your PSA LIFESAVER Smoke Alarm was designed for use in a residential environment. It is not designed for use in a recreational vehicle (RV) or boat.
  • Page 3: Table Of Contents

    Contents 1. Product Features And Specifications ..................4 2. Activation and RF Interlink Network ..................5 2.1 Setting Up an RF Interlink Network ..................5 2.2 Adding A Detector To An Existing RF Interlink Network............6 2.3 Resetting The 6000WB......................7 2.4 Connecting The 6000WB RF Baseplate to 6000DCW Wireless Smoke Alarms......
  • Page 4: Product Features And Specifications

    1. Product Features And Specifications Introduction Installing this wireless interlink baseplate onto the PSA Lifesaver 6000 Series 240VAC smoke alarms allows the smoke alarms to be interconnected wirelessly. When one smoke alarm activates, the RF interlink will trigger other smoke alarms in the same RF network.
  • Page 5: Activation And Rf Interlink Network

    2. Activation and RF Interlink Network This model is capable of interlinking with other PSA 6000WB models in domestic residential applications. When one RF interlink unit sounds an alarm, all other compatible RF units in the RF interlink network will alarm.
  • Page 6: Adding A Detector To An Existing Rf Interlink Network

    User Input Detector Response Timeout Step 4 Connect each additional smoke The Red LED of each unit will initially Join Mode will timeout in 15 minutes alarm on its RF baseplate. flash one second ON and one second after last unit joins. OFF.
  • Page 7: Resetting The 6000Wb

    Press the LINK button twice on any other Red LED on each unit will power off indicating Standby Mode wireless unit to close the Join Mode. Step 4 To re-join a network, please start over with Section 2.2 If any issues occur, please call PSA Technical Support.
  • Page 8: Connecting The 6000Wb Rf Baseplate To 6000Dcw Wireless Smoke Alarms

    2.4 Connecting The 6000WB RF Baseplate to 6000DCW Wireless Smoke Alarms This section explains how to setup the mains powered smoke alarm with the RF baseplate to wirelessly connect with LIFESAVER model 6000DCW RF interlink smoke alarms. The joining process is similar to previous steps.
  • Page 9: Wireless Faqs

    3. Wireless FAQs Answer Can the wireless units be connected Yes, the 6000WB and any 6000DCW smoke alarms can be paired together (on the bench) before together before installing them onto the ceiling. See Section 2.1 for installing them? details. What happens if units are powered Units will search for a network for 15 minutes after which all units will go up for the first time but no buttons...
  • Page 10 Wireless FAQs Answer What happens if the coordinator Nothing within 30min. After 30 min, push LINK button twice, and then drops from the network and comes push/hold LINK button for approx 4 seconds. Unit is reset. Push LINK but- back online?. ton twice to reopen network and rejoin.
  • Page 11: Installation Instruction

    Only connect to the specified models of smoke or heat alarm. Do not connect to any other brand of alarm/auxilary device unless approved by PSA. • The earth terminal connection provided is for termination purposes only and is NOT electrically connected within the sealed alarm / base units.
  • Page 12 • There are five terminals in the supply terminal block, marked 9V, A, SW, N and LOOP. It is important that the alarm be wired correctly to ensure correct operation. Incorrect wiring to the Smoke Alarm will damage the unit and void the warranty. •...
  • Page 13 To connect all wireless bases use only the Active and Neutral lines. Do not connect to the SW terminal. See diagram below. Household Cabling Active Neutral Household Cabling Active Neutral Wireless Wireless Wireless baseplate baseplate baseplate Wireless Wireless Wireless baseplate baseplate baseplate To expand an existing interconnected system, connect a wireless base to one alarm of the hardwired...
  • Page 14: Operation

    5. Operation OPERATION: The smoke alarm is operational, once it is connected onto the 6000WB base, which had been successfully configured into the wireless network (See Section 2). When products of combustion are sensed, the unit sounds a loud 85db pulsating alarm until the air is cleared. If the cause of the alarm is unknown, you should assume it was triggered by a real fire, and evacuate immediately.
  • Page 15: Cleaning Your Alarm

    6. Cleaning Your Alarm YOUR ALARM SHOULD BE CLEANED AT LEAST ONCE A YEAR. You can clean the interior of your alarm (sensing chamber) by using compressed air or a vacuum cleaner hose to blow or vacuum through the openings around the perimeter of the alarm. The outside of the alarm can be wiped with a damp cloth.
  • Page 16: Good Safety Habits

    7. Good Safety Habits DEVELOP AND PRACTICE AN ESCAPE PLAN • Install and maintain Fire extinguishers on every level of the home, in the kitchen, basement and garage. Know how to use a fire extinguisher prior to an emergency. • Make a floor plan indicating all doors and windows and at least two (2) escape routes from each room.
  • Page 17: Limitations Of Smoke Alarms

    8. Limitations Of Smoke Alarms WARNING: PLEASE READ CAREFULLY AND THOROUGHLY. • Fire safety in residential occupancies is primarily based on providing early warning to the occupants of the need to evacuate the building. This must be followed by their appropriate actions.
  • Page 18: Warranty And Liability

    3. To the extent permitted by law, the liability of PSA Products Pty Ltd arising from the sale or under the terms of this limited warranty shall not in any case exceed the cost of replacement and subject to this clause.
  • Page 19: Product Warranty Registration

    10. Product Warranty Registration Thank you for purchasing and installing the most trusted brand in fire, security and intercoms. To ensure you receive excellent after-sale product service we encourage you to register your products. There are a few important reasons to register your product: 1.
  • Page 20 THANK YOU FOR CHOOSING THIS SMOKE ALARM. Tested & Complies to Manufactured under ISO standard Australian Standards Quality Approved Manufacturing AS3786:2014 Another Quality Product By: PSA Products Pty Ltd 17 Millicent Street, Burwood, Victoria 3125, Australia Ph: (03) 9888 9889 Email:enquiry@psaproducts.com.au Webite:www.psaproducts.com.au...

This manual is also suitable for:

Lif6000wb

Table of Contents