Function setting - Vane Angle Control
This function is to adjust angle at which airflow is blow out.
1
Repeat pressing
icon flash.
2
Press
button to select active vane :
1 / 2 / 3 / 4 / All / Standard
Select Vane number using
❈ Vane number : No. 1, 2., 3, 4, all, or
standard
- Selected vane is in operation.
- Please verify the operating vane.
- To set the angle of all the vanes,
select 'all'.
- To set as the factory default settings,
select 'standard'.
3
Select wind angle using
and press
- The boundary of wind angle settings
can be changed to 5 levels or 6 levels
according to the product.
- When selecting 'standard' for Vane
number, the wind angle does not move.
4
Set the wind angles for the remaining
vanes as the same as above.
❈ There are products with vanes with
no. 1 and no. 2 only according to the
product types.
Press
button to exit.
5
❈ After setup, it automatically
gets out of setup mode if there
is no button input for 60 seconds.
❈ When exiting without pressing set
button, the manipulated value is not
reflected.
6
Press
button to complete and
active the setting process.
(Airflow direction function will be
released whenever setting vane angle)
7
Press
button to exit or
system will automatically release
without any input after 25
seconds.