Advertisement

SUPERSEDES: October 22, 2010
Plant ID: 001-3945
TS300 Series Sensors . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Applicable Documentation . . . . . . . . . . . . . . . . . . . . 2
Typical Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Representations and Warranties . . . . . . . . . . . . . . . . . 3
Installation Instructions. . . . . . . . . . . . . . . . . . . . . . . . . 3
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Static Electricity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About this Document . . . . . . . . . . . . . . . . . . . . . . . . 5
Inspecting the Equipment . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Mounting the Device . . . . . . . . . . . . . . . . . . . . . . . . 5
Wiring Information . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Communications Wiring . . . . . . . . . . . . . . . . . . . . . 10
© 2010 Taco Electronic Solutions, Inc.
Installation Guide
TS300 Series Sensors

Table of Contents

EFFECTIVE: November 17, 2010
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sensor Operation Diagnostics . . . . . . . . . . . . . . . .12
Display Screen Functions. . . . . . . . . . . . . . . . . . . .14
Fan Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
General Functions . . . . . . . . . . . . . . . . . . . . . . . . .14
Mode Functions . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Override Functions . . . . . . . . . . . . . . . . . . . . . . . . .15
Service Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Setpoint Functions . . . . . . . . . . . . . . . . . . . . . . . . .15
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Communications. . . . . . . . . . . . . . . . . . . . . . . . . . .18
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
502-017
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TS300 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for iWorX TS300 Series

  • Page 1: Table Of Contents

    Table of Contents TS300 Series Sensors ......2 Features ........12 Overview .
  • Page 2: Ts300 Series Sensors

    Using the digital wall sensor, the operator can monitor performance and edit operational settings. iWorX® TS300 Series Sensors are suitable for direct-wall, 2 x 4 electrical box, 1/4 DIN electrical box, or surface box mounting.
  • Page 3: Typical Use

    Document is being used. The iWorX® Sensor shall only be used for the applications identified in the product specifications and for no other pur- poses. For example, the iWorX® Sensor is not intended for use to support fire suppression systems, life support sys- tems, critical care applications, commercial aviation, nuclear facilities or any other applications where product failure could lead to injury to person, loss of life, or catastrophic property damage and should not be used for such purposes.
  • Page 4: Static Electricity

    TS300 Series Sensor Make all wiring connections in accordance with these instructions and in accordance with pertinent national and local electrical codes. Static Electricity Static charges produce voltages that can damage this equipment. Follow these static electricity precautions when handing this equipment.
  • Page 5: Before Installing

    Mounting the Device iWorX® TS300 Series sensors can be direct-wall, 2 x 4 electrical box, 1/4 DIN electrical box, or surface box mounted. See Figure 2 and Figure 3 for appropriate mounting dimensions. 502-017, Effective: November 17, 2010...
  • Page 6 TS300 Series Sensor Figure 2: LEFT: Mounting Dimensions for Direct-wall, 2 x 4 Electrical Box, and Surface Box Mounting. 502-017, Effective: November 17, 2010 © 2010 Taco Electronic Solutions, Inc.
  • Page 7 TS300 Series Sensor Figure 3: Mounting Dimensions for 1/4 DIN Electrical Box Mounting. 502-017, Effective: November 17, 2010 © 2010 Taco Electronic Solutions, Inc.
  • Page 8 TS300 Series Sensor Direct-wall Mount 1.Use mounting dimensions shown in Figure 2. 2.Feed S-Link wires through base plate. 3.Using two appropriate screws (use drywall anchors as necessary), mount base plate to wall (shown below). Figure 4: Direct Wall Mount.
  • Page 9 TS300 Series Sensor 1/4 DIN Electrical Box Mount 1.Use mounting dimensions shown in Figure 3. 2.Feed S-Link wires from electrical box through base plate. 3.Using two appropriate screws (not provided), mount base plate to electrical box using vertical mounting holes indicated in the figure below.
  • Page 10: Wiring Information

    CAUTION: Do not connect any power wiring to the sensor. Failure to observe this precaution will damage the sensor. Communications Wiring Communications wiring includes a connection between an iWorX® controller and an iWorX®TS300 Series sensor via the S-Link. Sensor Link (S-Link) Wiring S-Link wiring powers and enables the TS300 sensor.
  • Page 11 TS300 Series Sensor Wiring Checkout Verify wiring between TS300 sensor base plate and the iWorX® Controller is installed according to job wiring dia- gram, national and local wiring codes. Electronic Assembly and Cover Installation 1.Set electronic assembly onto bottom hooks of base plate.
  • Page 12: Features

    Address, Node Address, Alarms, and Errors are view-only frames. Values displayed in the Temperature Offset and Rel- ative Humidity Offset frames are adjustable. The iWorX®TS300 Series sensors provide the following types of diagnostic data. • Subnet Address (that the LCI2 has assigned to the attached controller) •...
  • Page 13 4.When you are finished adjusting the offset, release all buttons. After approximately 30 seconds the iWorX® TS300 Series sensor will revert to normal function, and the offset you pro- grammed will be added or subtracted from the actual room reading.
  • Page 14: Display Screen Functions

    General Functions Sensor time-out The iWorX® TS300 Series sensor times out and returns to the default display if left idle for 30 seconds. If sensor is in diagnostics mode, then time out is 40 seconds. To enter a selection or setpoint: Press any key besides the Up/Down Key or wait five seconds for the change to be accepted automatically.
  • Page 15: Override Functions

    The Override Key allows override of unoccupied mode setting within the controller in applications equipped with this feature. • The override LED indicator is lit if the iWorX® controller is overridden to the occupied mode from the unoccupied mode. • The override LED indicator flashes when timed override has less than 5 minutes remaining.
  • Page 16 Simply wait five seconds and the setpoint will be entered.) Table 3: LCD Icon Descriptions Note: LCD icons and icon definition vary depending on connected iWorX® Controller and its application. Refer to application documentation for more information.
  • Page 17: Specifications

    TS300 Series Sensor SPECIFICATIONS Sensors Temperature Sensor (TS301, TS303, TS305) • Type: Precision thermistor • Accuracy: ±3 °F (1.7 °C) • Range: 32 to 122°F (0 to 50 °C) Temperature Sensor (TS302, TS304, TS306) • Type: Band gap semiconductor •...
  • Page 18: Software

    It uses two-wire, unshielded cable and is not polarity sensitive. From these sensor models, the user can view and adjust application parameters. Maximum wire length allowed between a controller and the iWorX® TS300 series sensor is 200 ft. (61 m).
  • Page 19: Troubleshooting

    LCD displays value and setpoint. b Allows viewing of alarms and diagnostics. c LCD displays values and setpoints. TROUBLESHOOTING This section provides useful tips on troubleshooting the iWorX® TS300 Series Sensors. Table 6: Troubleshooting Tips Problem Solution LCD Remains Blank Check sensor and controller wiring and correct, if necessary.
  • Page 20 TS300 Series Sensor Getting Help Components within iWorX® TS300 controller cannot be field repaired. If there is a problem with a controller, follow the steps below before contacting your local TES representative or TES technical service. 1.Make sure controllers are connected and communicating to desired devices.

This manual is also suitable for:

Ts301Ts302Ts303Ts304Ts305Ts306

Table of Contents