Where is the fuse location my gate stop opening and closing button llight works

2 comments:
Mr. Anderson
February 10, 2025

The fuse is located on the control board of the SereneLife SLGATEOP gate opener. If the fuse is burned, it needs to be checked and replaced.

This answer is automatically generated

Larry Randle
February 11, 2025

It's not label on the diagram

Summary of Contents for SereneLife SLGATEOP

  • Page 1 SLGATEOP Automatic Sliding Gate Motor Sliding Gate Motor for Slide Gates Up to 1322lbs.
  • Page 2: Safety Instruction

    Please read this manual carefully before installation and use. Please do not forget to include this manual if you send the product to a third party. 1. Safety Instruction Please make sure that the power voltage being used matches with the supply voltage of gate opener (AC110V or AC220V);...
  • Page 3 2. Packing List (standard / detachable mounting base) Picture Name Quantity Main engine Manual release key Remote control Mounting accessories box Sprocket cover Chain link Chain Tie rod Square screw Round screw www.SereneLifeHome.com...
  • Page 4 Picture Name Quantity Door connecting plate Horizontal mounting plate Vertical mounting plate 4-10 Foundation bolt M8 4-11 Magnetic switch block Inner hexagon screw 4-12 M6×20 Hexagon screw M6×65 4-13 Hexagon screw M8×45 Nut M6 4-14 Nut M8 Flat washer φ6 4-15 Flat washer φ8 Spring washer φ6...
  • Page 5: Installation Drawing

    Packing List (optional) Picture Name Quantity Infrared sensor Wireless keypad Alarm lamp 3. Installation Automatic Sliding Gate Motor is applicable to gate weight less than 600kg, and length of the sliding gate less than 8m. The drive mode adopts the sprocket and chain transmission.
  • Page 6 4.1 Size of main engine and accessories 4.2. Size of main engine Detachable mounting base Figure 2 4.2.1 Size of embedded hole Detachable mounting base Figure 3 www.SereneLifeHome.com...
  • Page 7: Cable Installation

    4.3 Installation procedures 4.3.1 Preparation work before installation Please make sure that the sliding gate is correctly installed, the gate rail is horizontal, and the gate can be manually moved smoothly before installing the gate opener. Cable installation In order to guarantee the normal operation of the gate opener and protect the cables from damages, please bury the motor &...
  • Page 8 4.3.2 Main engine installation a. Dismantle the plastic housing on the main engine before installation and keep relevant fasteners properly; b. If you select the detachable mounting base, please assemble the base rst as shown in Figure 5; washer φ 6 Flat Flat washer washer φ...
  • Page 9: Chain Installation

    e. Unlock the main engine before installation, the unlock method is: take out the key cover, insert the key, and open the manual release bar till it rotates by 90° as shown in Figure 7. Then turn the output sprocket and the sprocket can be rotated easily;...
  • Page 10 Flat washer φ 8 Spring washer φ 8 Nut M8 Tie rod Nut M6 Spring washer φ 6 Flat washer φ 6 Gate Round screw Figure 9 If door frame is square, please use the square screw as shown in Figure 10 Flat washer φ...
  • Page 11 Installation of the chain between the small and big sprocket as shown in Figure 11 Figure 11 Installation of the sprocket cover as shown in Figure 12 Cross screw M4×10 Sprocket cover Figure 12 www.SereneLifeHome.com...
  • Page 12: Limit Switch Adjustment

    The distance between main engine and chain ends should be at least 30CM, as shown in Figure 13. ≥30cm Figure 13 Warnings · To ensure safety, install safety stop blocks on both ends of the rails to prevent the gate from running out of the rail. Before installing the main engine, make sure that the safety stop blocks are in place and whether it has the function of preventing the gate from running out of the rail or safety range.
  • Page 13 Installation position of magnetic limit switch as shown in Figure 14 and Figure 15 Gate Magnet Magnetic limit switch block Chain Figure 14 ≤20mm Main engine Magnet Magnetic limit switch block Chain chain wheel Gate Nut M8 Spring washer Φ 8 Flat washer Φ...
  • Page 14: Wiring Instruction

    4.3.5 Control board wiring 4.3.5.1 Standard control board Figure 16 Wiring instruction: 1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is Live wire, N is Neutral wire, and PE is grounding wire. 2. Connect LAMP to D1, D2; voltage: AC220V/50HZ; AC110V/60HZ. 3.
  • Page 15: Infrared Connection

    X7 Terminal Control button common terminal; Stop control button (N.O.); Gate close control button (N.O.); Gate open control button (N.O.). DIP Switch 1. External button switch. ON - Three button switch; OFF - Single button switch (X7 terminal CLS button can be used to circularly control OPEN/STOP/CLOSE/STOP of the main engine) 2.
  • Page 16 Adjustment and operation Remote control operation Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one button circularly on the remote control. OPEN CLOSE STOP Figure 18 Add extra remote control (remote control learning): Remove the main engine housing, then take out the upper cover of the control box, press the learning button AN1 on the control board, and indicator light LED2 will ash.
  • Page 17 4.3.5.2 Intelligent control board Figure 19 Wiring instruction: 1. Connect L and N to the power supply of AC220V/50HZ; AC110V/60HZ; L is Live wire, N is Neutral wire, and PE is grounding wire. 2. Connect LAMP to caution light; voltage: AC220V/50HZ; AC110V/60HZ. 3.
  • Page 18: Function Adjustment

    J5 Terminal (For the convenience of wiring, this terminal is accompanied with failure diagnosis light) 7. Power supply for ttings: +12VDC (Electric current ≤100mA) 8. Photocell input (N.C.); short out the device with terminal 9 (GND) if not used. 9. GND 10.
  • Page 19 Adjusting knob VR1: When meet obstacle reverse function is enabled (DIP switch 5 on OFF position and the motor assembled with the hall line). This knob is used for sensitivity adjustment of meeting obstacle. Clockwise rotation to reduce sensitivity of obstacle, counter-clockwise rotation to increase sensitivity of obstacle.
  • Page 20: Dip Switch

    Dip switch 1. Soft start function. OFF - enabled; ON - disabled. 2. Limit switch setting. OFF- normal open (N.O.); ON - normal close (N.C.). 3. Automatic close time. 4. Automatic close time. Setting for automatic close time: 3 OFF 4 ON: automatic close time is 12s, 3 ON 4 OFF: automatic close time is 24s, 3 ON 4 ON: automatic close time is 36s, 3 OFF 4 OFF: no automatic close function.
  • Page 21 Adjustment and operation Remote control operation Single button mode remote control: OPEN/CLOSE/STOP of main engine are controlled by one button circularly on the remote control. OPEN CLOSE STOP Pedestrian mode Figure 22 Add extra remote control (remote control learning): Remove the main engine housing, then take out the upper cover of the control box, press and hold the learning button S1 for 2 seconds, then the indicator light LEARN will be on;...
  • Page 22 Note: To disengage gate opener, move the gate to the middle position, then close the clutch and press the open button of external button switch to open the gate. If the gate opening direction is wrong, you can exchange the motor phase-sequence lines MOT2 and MOT1.
  • Page 23: Troubleshooting

    5.2 Troubleshooting Problems Possible Reasons Solutions 1.Switch on the power supply. 1.The power is off. The gate cannot open or 2.Check the fuse (code FU), 2.Fuse is burned. close normally, and LED change the fuse if burnt. 3.Control board power wiring with does not light.
  • Page 24: Warranty

    the magnetic limit switch can reach up the mounting requirement. Power supply line short circuit or Leakage switch tripped. Check wiring. motor line short circuit. Connect external receiver Remote control working Signal is blocked. antenna, 1.5 meters above distance is too short. ground.
  • Page 25 Features: · Black Motor Cover · Magnetic Limit Switch · Built-in Control Board without Soft Start-Slow Stop Function · 10-90 Seconds Gate Opening/Closing Time Depends on the Gate Weight and Length · Easy to Install · Suitable for All Types of Sliding Gates ·...
  • Page 26 Questions? Issues? We are here to help! Phone: (1) 718-535-1800 Email: support@pyleusa.com...