SJ-LR09 Wireless Manual Call Point User's Manual
Please read the User's Manual carefully in order to proper installation!
I. Description
The wireless manual call point (hereinafter referred to as "the manual call point") incorporates a
built-in wireless communication module. An alarm is reported by pressing the resettable button.
The manual call point alarm signals to host by wireless protocol. It is powered by 2×DC1.5V AA
lithium batteries and saves power. And it could report the batteries fault once battery-voltage is
low.
II. Technical parameters
1.
Operating voltage: DC3V (2×DC1.5V AA in serial connection)
2.
Quiescent current: <100μA
3.
Alarm current: <2mA
4.
Indicator: operating: indicator(green) flashes once per 60s; alarm: indicator(red) remains on
5.
Dimensions: 90mm×90mm×43mm
6.
Housing material: ABS
7.
Weight: approximately 138g
8.
Temperature range: -10℃~50℃
9.
Humidity: 0% to 95% RH (40℃±2℃, no condensation)
10. Resettable element: it can be easily reset with a supplied special key
III.Application
1.
Applicable places:
Houses, lounges, coffee houses, clubs, hotels, restaurants, apartments, inns, etc.
2.
Inapplicable places:
A. Places temperature over 40℃.
B. Extreme humidity places.
IV. Structural features
1.
Dimensions

Advertisement

loading

Summary of Contents for SANJIANG SJ-LR09

  • Page 1 SJ-LR09 Wireless Manual Call Point User’s Manual Please read the User’s Manual carefully in order to proper installation! I. Description The wireless manual call point (hereinafter referred to as “the manual call point”) incorporates a built-in wireless communication module. An alarm is reported by pressing the resettable button.
  • Page 2 Installation diagrams : screw the base : insert batteries : install front cover V. Instruction for use Indicator: operating: indicator (green) flashes once per 60s; alarm: indicator (red) remains on Low-voltage warning: the manual call point will report low-voltage fault once batteries voltage lower than 2.8V.
  • Page 3 If the manual call point has been activated, it needs a special reset key to reset. Please keep the reset key carefully after commission. Installation should follow GB50116-98 and GB50166-2007 standards. Address: Guangcai World Building, Nanshan Avenue, Nanshan District, Shenzhen City, China Postcode: 518054Tel: +86 (755) 2690 9106 Fax: +86 (755) 86223939 Service hotline: 400-7700-119 Website: www.sanjiang-security.com...