Chapter 3: Assembly - QED ADDP Operation Manual

Surface mounted automatic double diaphragm pump
Table of Contents

Advertisement

ADDP Manual
ASSEMBLY
NOTE: When operating and maintaining the system, disconnect air and
fluid lines cautiously to avoid spilling fluids.
• Wear safety goggles to protect eyes from any splashing or pressure
release.
• Wear chemically resistant rubber gloves when pulling the hoses from
the well to avoid skin contact with the product being recovered.
• The hose which carries the air from the pneumatic circuit to drive the
DDP is already connected
• Position the system on a level surface. The fluid level should not be more
than 22 feet below the DDP.
STEP 1 - LOCKING QUICK CONNECT INSTRUCTIONS
• Follow the instructions on Figure 4 for properly securing the locking
quick connects.
STEP 2 - AIR COMPRESSOR to PNEUMATIC SYSTEM - System Air Supply
Hose
• Connect the FEMALE air hose socket with 3/8 inch MPT to the
air compressor making sure to use the teflon tape on the threads.
(See Figure 2)
• Connect the MALE quick connect on the system air supply hose to the
FEMALE socket on the air compressor. (See Figure 2)
• A ach the FEMALE quick connect on the system air supply hose to
the MALE air supply quick connect near the air filter on the pneumatic
system. (See Figure 2)
Page 10
QED Environmental Systems

Chapter 3: Assembly