Advertisement

Quick Links

OWNER'S MANUAL FOR #309 BLOWER
READ ALL INSTRUCTIONS BEFORE USING BLOWER
IMPORTANT: Unpack blower immediately and check for damage to shipping. Place any damage claim
with delivering carrier, saving all packing materials for inspection. Our warranty covers manufacturer's
defects only. DO NOT return to shipper.
File instructions for future reference and ordering replacement parts.
A WORD ABOUT YOUR BLOWER. This blower is designed to blow CELLULOSE insulation fibers,
properly conditioned by agitation in the hopper. This unit is not designed to blow fiberglass, mineral wool,
or similar abrasive material, which would cause damage to fan and chamber. Consult the manufacturer for
a wide range of machines designed to handle all fibers.
Declaration of Incorporation -The 309 blower's intended use is with cellulose machines and is an integral
part of the machine's operation. The blower is not intended to be used as a separate piece of equipment as
this would create an unsatisfactory condition. The assembler performing final assembly of blower unit
must ensure proper installation to make certain that final health and safety requirements have been met.
Your blower is designed with an abrasive resistant fan and chamber, powered by a high speed, universal,
brush-type motor.
CHAMBER
SMALL
9"
MEDIUM
10"
This model carries a one (1) year warranty against defects in material and workmanship from date of
invoice to the original purchaser. If blower needs service during that time, call your supplier immediately.
Do not attempt to service blower as this would void warranty.
This warranty does not cover ordinary wear, which occurs during normal use of the machine. Materials
such as fiberglass and mineral wool, etc. because of their abrasiveness, are not recommended for use with
this blower.
This warranty does not cover damage to unit caused by heat (i.e armature, field coil). In most cases, heat
damage is a result of improper use. See operating instructions.
The warranty also excludes switches and cords – the use or abuse of which cannot be controlled.
The warranty also excludes damage or breakage due to carelessness, accidents, or improper use.
We do not assume responsibility for repairs made or attempted by unauthorized persons. Returns, in-
warranty, must be sent to our factory for examination and determination of the defect.
All blowers or parts must be returned prepaid with necessary information as to date of
purchase, model, and serial number with description of the problem and defect.
#309
16.8 amp Motor, 120V
(8.4 amp, 230V)
1.5 h.p. Motor
No load RPM 16,500
2016 Watts
FAN DIAMETER
PRODUCTION
6 ½"
800 lbs/hr
7 ½"
1000 lbs/hr

LIMITED WARRANTY

AMPS
12
| Chamber Outlet: 2" or 2 ½"
15
| Blower Intake: 2-3/8"
| Fan bore: 9/16"
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 309 and is the answer not in the manual?

Questions and answers

Summary of Contents for Krendl 309

  • Page 1 Declaration of Incorporation -The 309 blower’s intended use is with cellulose machines and is an integral part of the machine’s operation. The blower is not intended to be used as a separate piece of equipment as this would create an unsatisfactory condition.
  • Page 2 Fax: 419-695-9301 www.krendlmachine.com krendl@krendlmachine.com IF BLOWER WAS NOT PURCHASED DIRECTLY FROM KRENDL MACHINE CO., CONTACT YOUR SUPPLIER. Once blower is received, it will be inspected. In-warranty blowers will be repaired and returned immediately. Estimates of repair and charges will be provided for out-of-warranty units.
  • Page 3 (item #21). There are two carbon brushes on motor. Replace by inserting new brush in same direction. Attach brush plug. Use only Krendl carbon brushes. These brushes are manufactured specifically for this motor. Do not use substitute brushes as serious damage to the...
  • Page 4 TROUBLESHOOTING. IMPORTANT: If there is excessive noise, vibration, arcing of brushes, or other symptoms of trouble, STOP BLOWER IMMEDIATELY AND UNPLUG. Contact your supplier or qualified motor repair service before making inspection or repairs. SYMPTOM CAUSE SOLUTION Blower does not run. Blower switch in “off”...
  • Page 5 Excessive vibration. Fan imbalance. Clean material build-up. Inspect fan for broken blades. Bearing failure. Contact your supplier or qualified motor repair service.
  • Page 6 KRENDL MACHINE COMPANY February 2021 1201 Spencerville Rd. Delphos, Ohio 45833 U.S.A Phone: 419-692-3060 Fax: 419-695-9301 E-mail: krendl@krendlmachine.com PARTS LIST NO. 309 KRENDL BLOWER - 16 AMP. 1 1/2 H.P. SHAFT DIAMETER 9/16” CYLINDER 3 1/2” LONG DUMORE PART NO.
  • Page 7 Use an air hose to blow a constant stream of pressurized air into the motor housing of your Model #309 Blower. Be sure to concentrate the air into the vent holes on both ends of the motor housing (the brush end, as well as the plate end of the motor housing). Any build up of insulation in these vent holes can cause overheating and contamination of the motor housing, voiding your warranty.

Table of Contents