2. INTRODUCTION
Portable mode 2 charger simply plugs into a standard UK 3-pin socket for easy charging. Delay timing function enables users to
program delayed start time to benefit from off peak electricity tariffs. The intuitive LED offers users fault codes, charging time,
power and temperature displays. Supplied with storage case.
3. SPECIFICATION
Model No:.................................................................. EVPC2
Electrical Class: ............................................................... 1ph
Electrical Plug Type: ................................................ 3-Pin BS
EV Plug: ...................................................................... Type 2
Current: .................................................................. 10A Fixed
Voltage: ..........................................................................230V
Cable Length:.................................................................... 5m
Cable Specification: .............. EN50620-3*2.5mm²+2*0.5mm²
IP Rating: ........................................................................IP54
4. OPERATION
4.1.
LED STATE TABLE AND DISPLAY (fig.1)
LED Screen
Rated Current
Voltage
Electricity consumption
Charging time
Power
Constant current
4.2.
CHARGING
NOTE: Sealey strongly recommend that an RCD (Residual Current Device) is used
with this unit. You may obtain an RCD by contacting your local Sealey stockist.
4.2.1.
Plug Charger power cable into suitable power supply.
4.2.2.
Remove rubber protection cover from Charger unit cable and fully insert relevant Charging Cable. Connect cable to EV vehicle.
4.2.3.
Turn the mains power on and the LED interface will light up (fig.1).
4.2.4.
While the equipment is charging, the red light will be permanently on and the green
light will flash (fig.2).
4.2.5.
When charging finishes, indicated by all LEDs being off, disconnect the unit from
the power supply and disconnect the charging connector from the vehicle.
4.3.
TIMER FUNCTION
4.3.1.
With Charger powered up and disconnected from the EV vehicle, press the green
button (fig.2) to set the delay time. One press equals one hour, up to a maximum
delay of 10 hours.
4.3.2.
After time delay is set, connect Charging Cable to charging port on EV vehicle.
4.3.3.
When charging finishes, indicated by all LEDs being off, disconnect the unit from
the power supply and disconnect the charging connector from the vehicle.
5. MAINTENANCE
WARNING! Disconnect from Mains supply before performing any cleaning or maintenance.
5.1.
Cleaning and user maintenance should be carried out by competent persons.
5.2.
After use and before performing maintenance, unplug and disconnect the battery charger.
5.3.
Use a dry cloth to wipe all battery corrosion and other dirt or oil from the battery connectors, cords, and the charger case.
5.4.
Ensure that all of the charger components are in place and in good working condition.
5.5.
Servicing does not require opening the unit, as there are no serviceable parts.
5.6.
All other servicing should be performed by qualified service personnel.
5.7.
If the mains cable is damaged, DO NOT use until repaired.
5.8.
Store in supplied storage case inside a cool, dry place.
© Jack Sealey Limited
LED State
Fault Yellow
Ready
Off
EV Connected
Off
CP Error
Off
Charging
Off
Charge complete
Off
Fault
Flash