Advertisement

Quick Links

Original instruction manual
Luftreiniger R 150 silent

Advertisement

Table of Contents
loading

Summary of Contents for deconta R 150 silent

  • Page 1 Original instruction manual Luftreiniger R 150 silent...
  • Page 3 This instruction manual must be kept with the of product appliance at all times. A copy of this instruction must also be supplied when selling this appliance. Revision 0 Original instruction manual 1 / 53 Luftreiniger R 150 silent...
  • Page 5: Table Of Contents

    Warnings ....................26 5.1.1 Mains cable .................... 26 Assembly ............... 26 Initial operation ............. 28 Warnings ....................28 7.1.1 Mains cable .................... 28 7.1.2 Unsuitable mains voltage ............... 28 Revision 0 Original instruction manual 3 / 53 Luftreiniger R 150 silent...
  • Page 6 Disposal of appliances ..........49 Systems for documentation ......... 50 12.1 Type plate ..................... 50 12.2 EC/EU declaration of conformity pursuant to the low-voltage directive 2014/35/EU ................51 4 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 7: Information On Reading

    Synonym Personal protective equipment (PPE) Electromagnetic compatibility (EMC) BetrSichV Ordinance on Industrial Safety and Health DGUV German Social Accident Insurance Gerät Luftreiniger R 150 silent ICNIRP International Commission on Non-Ionizing Radiation Protection Signs Meaning  Guide to actions  Enumeration ...
  • Page 8 Minor or moderate injury may occur if the CAUTION hazard is not avoided. not safety- General information as well as user tips Information relevant and work recommendations for efficient and trouble-free operation. 6 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 9  This instruction states the remedy (possibilities for avoidance etc.). This instruction manual may contain additional indications in several chapters. These indications must only be understood in context. Revision 0 Original instruction manual 7 / 53 Luftreiniger R 150 silent...
  • Page 11: Legal Regulations

    The application area of appliancees Gerätes is the residential and commercial sector. Revision 0 Original instruction manual 9 / 53 Luftreiniger R 150 silent...
  • Page 12  the non-compliance with rules and regulations in the country of use and the statu- tory regulations and accident prevention regulations when dealing with the appli- anceem Gerät,  the operation of the appliancees Gerätes outside technical data. 10 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 13: Gerät

    The following labels are attached to the applianceem Gerät: Meaning Location Label Warning against dangerous Connection socket for the electrical voltage supply cable Warning against UV UV lamps (if installed) radiation Revision 0 Original instruction manual 11 / 53 Luftreiniger R 150 silent...
  • Page 14: Protective Conductor, Earthing And Equipotential Bonding

     To make it more difficult to remove the pre-filter improperly, an optional protective grille can be fitted. Note that this reduces the volume flow minimally. The following measured value for UVC radiation was determined with proper operation and built-in pre-filter: 12 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 15  Do not cover the air intake and outlet nozzles during operation.  Switch off the appliance with the power switch during longer interruptions.  Remove spilled substances immediately. Revision 0 Original instruction manual 13 / 53 Luftreiniger R 150 silent...
  • Page 16: After The Operation Phase

    The appliance is operated via a display. Only very little pressure is needed to tap on one of the buttons.  Do not touch the display with sharp objects. 14 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 17  The disposal of used filters may be subject to certain regulations or laws if they filter harmful substances.  Filters must be disposed of in accordance with legal regulations. Revision 0 Original instruction manual 15 / 53 Luftreiniger R 150 silent...
  • Page 18: According To The Location Of The Hazard

    Touching a defective supply cable may result in death or serious injury. Do not damage the supply cable (e.g. by vehicle overrun, tearing, squeezing).  Regularly check the supply cable for damage.  Have defective supply cable replaced before use by the deconta service or a qualified electrician." 16 / 53...
  • Page 20: Appliance Description

    HEPA filter Performance data Description Value Mains connection 230 V / 50 Hz Performance 220 W Standby 1.3 W Protection type IP 20 Mains input fuse 18 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 21  Activated carbon  HEPA filter - small 100% * The values were determined at a distance of 1 metre from the appliance, the basic volume was 33 dB (A). Revision 0 Original instruction manual 19 / 53 Luftreiniger R 150 silent...
  • Page 22: Order Numbers - Replacement Filter / Uv Lamp (If Installed)

    Position of filter and UV lamp (if installed) Pos. Description HEPA filter - large Item no. AU3664 UV lamp (if installed) Item no. AE2257 Pre-filter Item no. BO2088 20 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 23 Please note: If odours are not removed satisfactorily, please reduce the power of the air purifier to reduce the air speed and thus increase the exposure time when the air flows through the activated carbon. Revision 0 Original instruction manual 21 / 53 Luftreiniger R 150 silent...
  • Page 24 Please note: If odours are not removed satisfactorily, please reduce the power of the air purifier to reduce the air speed and thus increase the exposure time when the air flows through the activated carbon. 22 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 25: Filter Description/Classification

    Grip protection double-sided The HEPA filters used by deconta achieve a degree of separation > 99.995% (H14) in accordance with EN1822 at the volume flow indicated on the filter certificate. At higher volume flows the filter performance, measured according to EN1822, will be lower.
  • Page 26: Electrical Connection

    Abb. 5 Display Pos. Description Pos. Description Filter display + Button UV lamp (if installed) Fan performance Manual mode On / Off button Menu - Button Automatic mode 24 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 28: Transport

    Transport Warnings 5 Transport The R 150 silent air purifier has steering rollers and is therefore easy to transport even for use in other rooms. 5.1 Warnings 5.1.1 Mains cable WARNING Electric shock due to defective supply cable. The appliance is connected to the power supply system via the house connection.
  • Page 30: Initial Operation

    The appliance may be damaged if it is connected to an unsuitable mains voltage.  Check whether the voltage indicated on the rating plate matches the local mains voltage. 28 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 32: Operation And Control

     Do not damage the supply cable (e.g. by vehicle overrun, tearing, squeezing).  Regularly check the supply cable for damage.  Have defective supply cable replaced before use by the deconta service or a qualified electrician." 8.1.2 UV lamp (if installed) WARNING The UV lamp emits short-wave UV-C radiation.
  • Page 33: Operating Modes

    In combination with HEPA filters and activated carbon to separate solid particles and volatile pollutants, UV technology is also recommended for persons who suffer from allergies and asthma. Revision 0 Original instruction manual 31 / 53 Luftreiniger R 150 silent...
  • Page 34: Automatic Mode

    Filter display Automatic mode Menu Fan performance Abb. 9 Interface displayed under menu Pos. Description Pos. Description Home button Settings for UV lamps (if installed) Setting for automatic mode 32 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 35 Activate or deactivate UV lamps (if installed) in night mode.  UV lamps (if installed) in day mode: Activate or deactivate UV lamps (if installed) in day mode. Revision 0 Original instruction manual 33 / 53 Luftreiniger R 150 silent...
  • Page 36: Setting The Uv Lamps (If Installed) In Automatic Mode

    You have activated the UV lamp in day mode (see previous page) and selected a burning time of 60 minutes. This means that the UV lamps light up for 60 minutes after reaching the start time for the day mode 34 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 37: Settings - Filter Change Intervals

    A soon expired interval is indicated in the main menu by a yellow filter indicator. If the indicator lights up red, the maximum operating hours have been reached. Abb. 15 Filter display Revision 0 Original instruction manual 35 / 53 Luftreiniger R 150 silent...
  • Page 38: System Settings

    8.4 System settings Abb. 17 “System settings” button Tap the “System settings” button to open the menu for setting the date, time, display brightness and operating status at restart. 36 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 39: Display Brightness

    (reset to factory defaults) Abb. 19 “FACTORY RESET” button In the system settings, the air purifier can be reset to its factory defaults by tapping the yellow “FACTORY RESET” button. Revision 0 Original instruction manual 37 / 53 Luftreiniger R 150 silent...
  • Page 40: Sleep Mode

    The reset must be confirmed by tapping on the green tick or can be cancelled by tap- ping on the red X. 8.5 Sleep mode Abb. 21 “Sleep mode” button Tap the “Sleep mode” button to darken the display. 38 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 41: Key Switch Option

    The key switch is located inside the appliance under the cover. Abb. 22 Key switch A lock symbol appears on the display. Abb. 23 Display with key symbol Revision 0 Original instruction manual 39 / 53 Luftreiniger R 150 silent...
  • Page 42: Filter Change

     To close the cover, hold the outer edge of the cover with both hands so that fingers and other parts of the hand cannot get between the cover and housing. 40 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 43 Filter change Warnings Abb. 24 Filter display in the display If it is necessary to change the filter, it is indicated by the colour of the filter indicator. Revision 0 Original instruction manual 41 / 53 Luftreiniger R 150 silent...
  • Page 44: Change Of Pre-Filter, Uv Lamps And Large Hepa Filter

     Loosen the lock nuts of the two pre-filter holders and turn the holders so that the filter can be removed. Abb. 26 Lock nuts and removal of the filter 42 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 45  Unscrew the wing screws (4 pieces) of the filter clamping bars and remove clamping bars. Wing screw Filter clamping Abb. 28 Wing screws and filter clamping bars Revision 0 Original instruction manual 43 / 53 Luftreiniger R 150 silent...
  • Page 46: Changing The Optional Activated Carbon Mat

     Remove the HEPA filter from the top. Abb. 29 Remove HEPA filter 9.3 Changing the optional activated carbon mat  Remove the cover; it is held only by magnetic force. Abb. 30 Cover 44 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 47: Change Of Activated Carbon Cell And Hepa Filter - Small (Optional)

     Remove the cover as described on the previous page.  Unscrew the wing screws (4 pieces) of the filter clamping bars and remove clamping bars. Abb. 32 HEPA filter - small Revision 0 Original instruction manual 45 / 53 Luftreiniger R 150 silent...
  • Page 48  The small HEPA filter can now be removed. Abb. 33 Removing the HEPA filter “small”  The activated carbon cell below can now be removed. Abb. 34 Removing the activated carbon cell 46 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 50: Cleaning

    Before cleaning, please remove the mains plug from the socket. Use a dry, soft cloth for cleaning. Chemical solvents and cleaning agents should be avoided because they can damage the surface and/or lettering of the appliance. 48 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 51: Disposal Of Appliances

     The disposal of used filters may be subject to certain regulations or laws if they filter harmful substances.  Filters must be disposed of in accordance with legal regulations. Revision 0 Original instruction manual 49 / 53 Luftreiniger R 150 silent...
  • Page 52: Systems For Documentation

    12 Systems for documentation 12.1 Type plate deconta GmbH Im Geer 20 46419 Isselburg Name: Air purifier Type: R 150 silent Year of manufacture: 2020 Type number: Mains connection: 230 V, 50 Hz Power: 220 W Standby: 1.3 W Abb. 35 Type plate The type plate states the minimum data of the appliance.es Gerätes The minimum da-...
  • Page 53: Ec/Eu Declaration Of Conformity Pursuant To The Low-Voltage Directive 2014/35/Eu

    We hereby declare that the appliance designated below, on the basis of its design and construction and in the form brought onto the market by us is in accordance with the relevant basic safety and health requirements of the EC directives. Description: Air purifier R 150 silent Identification number: Type no.
  • Page 54 Location Date Name - Managing director - 52 / 53 Original instruction manual Revision 0 Luftreiniger R 150 silent...
  • Page 55 HEPA filter - small ....................45 Abb. 33 Removing the HEPA filter “small” ................. 46 Abb. 34 Removing the activated carbon cell ..............46 Abb. 35 Type plate......................50 Revision 0 Original instruction manual 53 / 53 Luftreiniger R 150 silent...
  • Page 56 Reproduction, transmission or disclosure of the contents of this instruction manual are not permitted without express permission from deconta GmbH. Infringements of this copyright could lead to a claim for compensation. All rights reserved in the event of granting a patent or registration of a utility model.

Table of Contents