Download Print this page

Sealey SA720.V2 Instructions page 2

Air mini sander kit 50mm 35pc

Advertisement

3.
AIR SuPPLy coNNEcTIoN
3.1.
Air Supply
WARNING! Ensure the air supply is clean and does not exceed 90 psi while operating the sander. Too high an air pressure and
unclean air will shorten the product life due to excessive wear, and may be dangerous causing damage and/or personal injury.
3.1.1. Ensure sander air valve (or trigger) is in "off" position before connecting to air supply.
3.1.2. You will require an air pressure of 90psi, and an air flow according to specification.
3.1.3. Drain the air tank daily. Water in the air line will damage the sander.
3.1.4. Clean air inlet filter weekly. Recommended hook-up is shown in fig.1.
3.1.5. Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should be
1/4" I.D. and fittings must have the same inside dimensions.
3.1.6. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.
3.2.
couplings
3.2.1. Vibration may cause failure if a quick change coupling is connected directly to sander. To overcome this, connect a leader
hose to the sander. A quick change coupling may then be used to connect the leader hose to the air line recoil hose. See figs 1 & 2.
fig.1
4. oPERATING INSTRucTIoNS
LEAD PAINT WARNING! Ensure you read and comply with the information in
Safety section 1. regarding the hazards associated with lead paint.
4.1
Ensure the pad (fig.3.A) is securely fitted to the spindle (fig.3.B). Prevent the spindle
from turning using the spanner provided and turn the pad clockwise.
4.2
Attach the appropriate sanding disc (fig.3.C) to the pad by screwing on clockwise.
4.3.
Press trigger (fig.3.D) to start the sander.
4.4.
The air flow may be adjusted by turning control knob (fig.E).
NoTE: The sander is designed for dry use only. DO NOT use with water or any other liquids.
5. MAINTENANcE
WARNING! Disconnect sander from air supply before changing accessories, servicing or
performing maintenance. Replace or repair damaged parts. Use recommended parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
5.1.
Clean the sander after use and change pad if required.
5.2.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy check
the air supply and follow instructions in Section 3.
b) Grit or gum deposits in the tool may also reduce performance. Flush the tool out with gum solvent oil or an equal mixture of SAE
No 10 oil and paraffin. Allow to dry before use.
c) If you continue to experience problems, contact your local Sealey service agent.
5.3.
When not in use, disconnect from air supply, clean the sander and store in its case which should be placed in a safe, dry, childproof
location.
Declaration of conformity
We, the sole importer into the UK, declare that the product listed here is in conformity with the following EEC standards and directives. The construction
file for this product is held by the Manufacturer and may be inspected, by a national authority, upon request to Jack Sealey Ltd.
2" Mini Disc Air Sander
MODEL: SA720.V2
98/37/EC Machinery Directive
93/68/EEC Marking Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPoRTANT: No liability is accepted for incorrect use of this product.
WARRANTy: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INfoRMATIoN: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave your full name, address and postcode.
Sole uK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Tools.
01284 757500
01284 703534
fig.2
fig.3
A
B
C
D
12th January 2009
www.sealey.co.uk
Web
sales@sealey.co.uk
email
SA720.V2 ISSUE No:1 12/01/09
E

Advertisement

loading