uponor Composite Pipe System Sprinkler:
MlC-S Pipe System for Sprinkler Ceilings
D
uponor Verbundrohrsystem sprinkler: MLc-s rohrsystem für sprinklerdecken
nl
uponor meerlagenleidingssysteem sprinkler: MLc-s leidingsysteem voor sprinklerplafonds
notice is to be taken of the uponor sprinkler MLc-s
gB
installation instructions. Before installation, the plumber
must read, understand and heed these instructions. the
uponor unipipe sprinkler MLc-s system components
are correlated and tested one to the other. We assume
no warranty for the components of other manufactur-
ers. subject to technical modifications!
only tested parts may be used to construct the sprinkler
system. the suitability of the respective components
must be documented by a test report or certificate from
an authorised testing institution for sprinkler systems
(e.g. Vds certificate). the approval for the uponor
sprinkler MLc-s system components is documented
by the Vds certificate dated 17.10.2006.
the instructions, references and laying and processing
instructions of the technical information – „uponor
composite pipe system sprinkler: MLc-s pipe system for
sprinkler ceilings" for the use, planning, processing and
installation of the uponor sprinkler MLc-s system must
also be kept to and followed.
M o n ta g e a n l e i t u n g
M o u n t i n g i n s t r u c t i o n s
the guideline Vds cEA 4001:2003-01 „specifications
for sprinkler systems – Planning and installation" must
be observed when planning and constructing sprinkler
systems.
Requirements for the tools
All the tools used to install the sprinkler ceiling must be
free of visible damage and dirt. in your own interest,
please check the tools before you start with installation.
Damaged (worn) tools must be replaced. only the
original uponor tools described in this manual may be
used to cut, bevel and bend the pipes. they are
specially adapted and tested for the uponor sprinkler
MLc-s system.

Advertisement

loading
Need help?

Need help?

Do you have a question about the MLC-S and is the answer not in the manual?

Questions and answers

Summary of Contents for Uponor MLC-S

  • Page 1 MlC-S Pipe System for Sprinkler Ceilings uponor Verbundrohrsystem sprinkler: MLc-s rohrsystem für sprinklerdecken uponor meerlagenleidingssysteem sprinkler: MLc-s leidingsysteem voor sprinklerplafonds notice is to be taken of the uponor sprinkler MLc-s the guideline Vds cEA 4001:2003-01 „specifications installation instructions. Before installation, the plumber for sprinkler systems –...
  • Page 2 Vóór de montage moet de verwerking en installatie van het uponor sprinkler installateur deze handleiding lezen, begrijpen en MLc-s systeem moeten in acht worden genomen en opvolgen. De uponor sprinkler MLc-s systeemcompo- dienen te worden nagekomen.
  • Page 3 (item no.: 99 64 00) and mounted bevelling tool 32 mm without hand unipipe sprinkler MLc-s pipes of hand toggle to produce a circumfe- toggle can be operated as a tool in 32 x 3 mm.
  • Page 4: Visual Check

    Following bevelling a circumferenti- all Pe shavings must be unipipe sprinkler MLc-s pipe end al chamfer with a depth of at least removed after bevelling. as to whether a uniform circum- 2 mm must be present. only this...
  • Page 5 4. installation – press fittings Montage Pressfittings Montage persfittingen open pressing jaws and put against Push pipe into the fitting up to the the red press stop ring made of stop. the correct insertion depth plastic. the contours of the pressing can be checked from the appea- jaws snap into the press sleeve rance of the pipe in the vision hole.
  • Page 6 5. installation – Repair coupling Montage Reparaturkupplung Montage reparatiekoppeling After bending out a pipe end, slip Bend in (1) pipe end and push Firstly press (1) the pressing point the compensating side (= deep repair coupling back (2) until the with the short insertion depth.
  • Page 7 Het uitlijnen dan wel het justeren van de uponor Sprinkler MlC-S installatie na de druktest is verboden. Wanneer ondichte persverbindingen worden geconstateerd, mogen deze niet worden nageperst.
  • Page 8 V.-s. A. Lozenberg 4 1932 Zaventem Beligië t +32 (0) 2721 15-70 F +32 (0) 2725 35-53 W www.nathan.be e info@nathan.be uponor gmbH t +49 (0)9521 690-0 industriestrasse 56 F +49 (0)9521 690-710 97437 Hassfurt W www.uponor.de germany e info.de@uponor.com...