Introduction How it works: A PC is connected to a vehicle through the VSI-2534 “Pass-Thru device” to the OBD-II J1962 connector and on to the ECUs. The VSI-2534 provides the translation interface between the PC and the vehicle or module.
- 40 C to + 85 C Power Connector The VSI-2534 can be powered via either a power jack (12V DC) OR via the supplied OBD II cable attached to the vehicle. (See 1.3.1 for more information on 12V DC usage) WARNING: The VSI-2534 SHOULD NOT be powered via the power jack AND the supplied OBD II cable SIMULTANEOUSLY.
The Toggle Switch can be used to simulate the vehicle ignition switch (on/off) when the VSI-2534 is powered via a 12V DC input. An example of this scenario would be reflashing on the bench. When powered via. the supplied OBDII cable, the Toggle Switch is not active.
▪ Vehicle Connection – Indicates that the vehicle network connection is established / active. ▪ Power – Indicates that the VSI-2534 is connected to a power supply (either via the jack plug or through a vehicle connection), and whether or not the unit is operating properly.
“Next”. 2. Exit all open Windows programs and click “Next” to continue. 3. Choose Destination Location for the installation. The default location is C:\Dearborn Group Products\VSI-2534. Click “Next” to continue. Page | 9...
Page 10
4. Click “Next” to continue. 5. Installing… 6. Ensure that you do not have the VSI-2534 hardware connected to the PC’s USB port. Click “OK” to continue. 7. Installation is complete. Click “Finish”, then click “OK” to reboot the PC.
Step 1: Connect the VSI-2534 to a power source (Power adapter or powered from the OBD II cable). Note: do not power unit from multiple sources. Power LED must be a solid Green.
OBD II cable). Note: Do not power unit from multiple sources. Power LED must be a solid GREEN. Step 2: Connect the VSI-2534’s USB cable to the PC that the software was installed on and note that the Power LED is a solid Green and the PC Connection LED is a solid RED.
3.3 Hardware Configuration Information By running the “VSI-2534 Config Utility”, located in Start > All Programs > DGTech VSI- 2534, a user can find out Hardware version, protocol support, and other information. The “Get Firmware Version” button provides the Firmware version of the VSI-2534 hardware.
DG Update is an application that is installed with your VSI drivers. It will run (by default) once every 30 days, and will keep you up-to-date with the latest versions of drivers for all your DPA, DG Diagnostics, and VSI-2534 products. With this application running regularly and Automatic Firmware Update (see DPA user manual) turned on, this will keep your DPAs up-to-date with drivers and firmware.
internet to check for updates." messages), ensure that your firewall or virus protection will allow a connection to the following Internet host/site and port: fh.dgtech.com, port 8888. There are too many firewall and virus programs on the market to cover in this manual, however if you contact your network administrator and give him the host and port number, he should be able to configure your PC to allow the communication.
Out of date message box Progress bar and Download button shown In this case, the VSI-2534 drivers are out of date (red), the user will be presented with a prompt notifying them that there are updates available. Only if updates are available will the Download button and progress bar show up on the screen.
When you click the Download button, you will be prompted to confirm starting of the download. Prompt asking if drivers should be downloaded Note: The DG Update application can only download and install one item at a time. The user will be prompted for whichever one they want to update first. After choosing Yes, the program will download the drivers and update the progress bar while doing so.
4.7 Hardware/Firmware Update of the VSI-2534 Step 1: Go to: Start>All Programs>DGTech VSI-2534>FirmwareUpdater. *NOTE: Adaptor must be plugged in Select the drop-down menu for “Adapter” and select “VSI-2534 USB”. Step 2: Click on “Yes”. Step 3: Updating the Firmware... Step 4: Firmware has been updated. Click “OK”...
For users in the United States, technical support is available from 9 a.m. to 5 p.m. Eastern Time. You may also fax or e-mail your questions to us. For prompt assistance, please include your voice telephone number. DG Technologies Technical Support Phone: (248) 888-2000 Fax: (248) 888-9977 E-mail: techsupp@dgtech.com...
Cables (both USB and vehicle) are warranted for 90 days. DG Technologies, Inc. will, at its option, repair or replace, at no cost to the customer, products which prove to be defective during the warranty period, provided the defect or failure is not due to misuse, abuse, or alteration of the product. The customer is responsible for shipment of the defective product to DG.
Farmington Hills, MI 48335 Phone (248) 888-2000 Fax (248) 888-1188 Troubleshooting 7.1 VSI-2534 Validation Utility Please refer to the “DG VSI-2534 Validation Utility User Guide” found in: Start>Programs>VSI-2534>Documentation. 7.2 Windows “Side-by-Side” Error Call Technical Support for assistance. 248-888-2000 7.3 OEM Application Troubleshooting Please refer to the “DG OEM Application Troubleshooting Guide”...
Not Used 3, 8, 17 -19, 21 - 23 * NOTE: These pairs of pins are either connected together in the VSI-2534 tool or connected in the OBD II cable. Pins 6 and 24 are connected together within the VSI-2534 tool.