3. OPERATING INSTRUCTIONS
F
WARNING! Before use, ensure you read, understand and comply with the Honda Engine Owner’s Manual and the safety
p
instructions in this document. Ensure you fully understand the application and limitations, as well as the potential
hazards, of the generator.
3.1.
BEFORE STARTING THE GENERATOR
1. Ensure you have read the engine manual and all specification charts.
2. Fill engine to correct level with the specified grade of oil.
3. Check fuel level. Do not over-fill the fuel tank.
4. Ensure all electrical loads are disconnected.
3.2.
STARTING THE GENERATOR
1. Ensure you have performed all actions in 3.1. above.
2. Turn on fuel tap (if fitted).
3. Set choke to correct position. Note: If starting a warm engine, move the choke control to ‘No Choke’ position.
4. Set the engine ‘Run’ lever/switch to the ‘On’ or ‘Run’ position.
5. Grasp the recoil handle and pull rope slowly until some resistance is felt. Let rope rewind slowly, then pull with a rapid full arm
stroke. Let rope slowly return.
6. When engine starts, move choke lever to half choke position until engine runs smoothly and then to ‘No Choke’ position.
7. If engine fails to start, repeat the procedure from 3.2.3. If it still will not start, refer to ’Trouble-Shooting’ section. If necessary contact
your authorised Sealey service agent.
3.3.
USING THE GENERATOR
1. Allow the engine to warm up (approximately 3 minutes).
2. Select the correct voltage output by adjusting the voltage selector switch (where fitted).
3. Connect the equipment to the generator socket. WARNING!: Do not exceed the wattage capacity of the generator.
4. Always observe the safety instructions of the equipment being used.
3.4.
TO STOP THE GENERATOR
1. Disconnect the electrical load.
2. Allow the engine to stabilise.
3. Stop engine by moving the engine ‘Run’ lever/switch to ‘Off’ or ‘Stop’ position.
4. Turn off fuel tap (if fitted).
3.5.
STORAGE
If you store the generator for more than 30 days, use a fuel additive such as “STA-BIL¨, “Fuel Fresh¨, or equivalent to prevent
fuel gum deposits from forming.
Store the generator in a safe, dry, childproof area.
4. MAINTENANCE
4.1.
GENERATOR MAINTENANCE
Keep the unit clean and dry. A damp cloth may be used to wipe exterior surfaces clean. Use a soft brush to loosen caked dirt, then
use a vacuum system to remove loosened dirt. Never use a forceful spray of water to clean the generator.
4.2.
ENGINE MAINTENANCE
Refer to the Engine Owner’s Manual for periodic maintenance of the engine.
In particular oil, air filter and spark plug must be changed regularly.
All other maintenance must be carried out by qualified staff, contact your local Sealey service agent.
5. TROUBLESHOOTING
PROBLEM
Engine will not start.
Engine runs rough.
PORTABLE GENERATORS
HG50.25, HG55.28, HG80.44, HG130.74
Models:
98/37/EC Machinery Directive
73/23/EEC Low Voltage Directive
89/336/EEC EMC Directive
BS EN60335 - 1:1995 + Amendments.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required
for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
p
CAUSE
ACTION
Fuel tap not turned on.
Turn fuel on.
No fuel in tank.
Fill fuel tank.
Oil not filled to correct level.
Fill oil to correct to level.
Engine run switch not turned on.
Set engine control correctly.
Choke not set correctly.
Set engine control correctly.
Spark plug fouled.
Clean/replace spark plug.
Air cleaner blocked.
Clean/replace air filter.
Air cleaner blocked.
Clean/replace air filter.
Spark plug fouled.
Clean/replace spark plug.
Choke set incorrectly.
Set engine control correctly.
Dirty/stale fuel.
Drain and replace fuel.
Declaration of Conformity
are in conformity with the following standards and directives.
The construction files for these products are held by the Manufacturer and may be inspected, by a national authority,
upon request to Jack Sealey Ltd.
Sole UK Distributor,
Sealey Group,
Bury St. Edmunds, Suffolk.
PROBLEM
No electrical output.
We, the sole importer into the UK, declare that the products listed here
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
01284 703534
01284 757500
CAUSE
ACTION
Voltage selector switch
incorrectly positioned.
Select the correct voltage.
Circuit breaker tripped.
Re-set circuit breaker.