LG LRSES2706V /01 Service Manual page 24

Table of Contents

Advertisement

Compressor
1. Information of linear compressor
The information tag provides compressor model, refrigerant, serial number and safety approval
Name Plate
Size: 90mm X 20mm
1
5
2
4
There are two types of controllers used in the linear compressor system.
- The "A"-inverter system is used with the FLE165NAMA compressor.
FLE165NAMA
A-Inverter
System
1. Compressor Model
2. Corresponding Controller Model
3. Standard Print
- Applied OLP : THERMALLY PROTECTED
- Unused OLP : PROTECTION ELECTRONIQUE(LG Drive Only)/ELECTRONICALLY PROTECTED(LG Drive Only)
4. Serial Number (Example)
5. Safety Approval
Refrigerator
Controls the
algorithm
according to
various
conditions.
Compressor Label
FLE 165 N A M A
- FLE
- 165=16.5
cc/rev
- L : LBP with R134a
- N : LBP with R600a
604X01276 O 10 – 1 6A471
Lot No.
Year(2016)
Comp Drive
Inverter
VVVF
**VVVF : Variable Voltage Variable Frequency
**CVCF : Constant Voltage Constant Frequency
24
Copyright © 2020 LG Electronics Inc. All rights
reserved. Only training and service purposes.
- A : A-Control
- M :220-240V / 50/60Hz
A,B,C,D
Series NO.
Product Line
Date
Month(1,2,3,...O,N,D)
Compressor
Stroke
Modulation