Superior Fireplaces VRT3036 Quick Start Manual page 2

Vent-free fireplaces

Advertisement

Cat. #
Model
F0304
VRT3036B
F0305
VCT3036B
F0310
VRT3036WS
F0311
VCT3036WS
F0312
VRT3036RS
F0313
VCT3036RS
F0314
VRT3036RH
F0315
VCT3036RH
Mantel Clearance
Wall board or facing
material (above
firebox) may be of
combustible material,
including decorative
mantel ornaments or
other similar projec-
tions off of the facing
material.
Framing
Material
Firebox
Wire-mesh
Screen
Mantel from Top of Opening
12" (305 mm)
16" (407 mm)
20" (508 mm)
Nails or Wood
Screws
Nailing Flange
Printed in U.S.A. © 2016 Innovative Hearth Products
P/N 900660-01 REV.
A 02/2017
VRT3036 AND VCT3036
Type
Interior
Weight
Radiant
Black Interior
184 lb.
Louvered
Black Interior
184 lb.
Radiant
WS refractory
184 lb.
Louvered
WS refractory
184 lb.
Radiant
RS refractory
184 lb.
Louvered
RS refractory
184 lb.
Radiant
RH refractory
184 lb.
Louvered
RH refractory
184 lb.
Mantel Shelf
Note: Any portion of the
Inch (millimeter)
mantel shelf must NOT
extend beyond this profile.
12 (305)
6-3/4 (172)
1-1/2 (38)
20
(508)
Noncombustible
16
Material May
(407)
Project Off this
Surface above
12
the Firebox Hood
(305)
Note: All vertical
measurements are
Supplied
from top of fireplace
Firebox Hood
hood opening to
Must Be Used
bottom of mantel shelf.
at All Times
These minimum
clearances replace any
other recommended
clearances supplied
with your ANSI Z21.11.2
approved gas logs.
Mantel Depth Allowed
1-1/2" (38 mm) max.
6-3/4" (172 mm) max.
12" (305 mm) max.
Cu. Ft.
32.4
PFS
32.4
32.4
C
32.4
32.4
Report No. F12-020
32.4
32.4
32.4
Inch (millimeter)
Example
1/2
1
(13)
(26)
Minimum Wall and Ceiling Clearances
A. Clearances from the side of the fireplace cabinet to any combustible
material and wall should follow diagram shown here.
Example: The face of a mantel, bookshelf, etc. is made of combustible
material and protrudes 3-1/2" from the wall. This combustible material
must be 4" from the side of the fireplace cabinet.
B. Clearances from the top of the firebox opening to the ceiling should not
be less than 42".
C. When the firebox is installed directly on carpeting, vinyl tile or other
combustible material, other than wood flooring, the firebox should be
installed on a metal or wood panel extending the full width and depth of
the enclosure.
D. Clearances from the bottom of firebox to the floor is 0".
INTERNAL WALL
INSTALLATION
FULL
PROJECTION
INSTALLATION
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Specifications and clearances are subject to change without notice.
Refer to Installation and Operation Manual before installation of these
appliances for updated dimensions and instructions.
These appliances comply with National
Safety Standards and are listed by PFS Cor-
®
poration to ANSI Z21.91 Ventless Firebox
US
Enclosures for Gas-Fired Unvented Decora-
tive Room Heaters and is approved for use
with appliances listed to ANSI Z21.11.2
decorative type unvented room heaters.
2
4
6
8
10
12
14
(51)
(102)
(153)
(204)
(254)
(305)
(356)
CORNER
INSTALLATION
FLUSH
INSTALLATION
12-1/4 (312)
10-1/2 (267)
8-3/4 (223)
7 (178)
5-1/4 (134)
3-1/2 (89)
1-3/4 (45)
7/8 (23)
1/2 (13)
16
(407)
Page 2 of 2