Warranty Regal Components AB grants warranty according to Nordiska leveransbestämmelser (NL09) in applicable areas or Orgalime S2012. Warranty is not provided for defects due to improper use, storage or excessive stress on the product.
Regasense is a part of Regal Components | Product description Part design RCL41 RCL41P RCL40 Sensor body Sensor header Flange sensor tube Sensor tube Sensor rod PUR cabel output PUR cabel seal Wire output Rev. no. RCL40 & RCL41 2021_1...
Regasense is a part of Regal Components | Inductive technology Regasense RCL40 and RCL41 are inductive linear sensors and the sensors are based on the eddy current principle. The sensor tube is mounted in the piston of the cylinder and the sensor rod contains a coil. The sensor will detect the change in inductance that is proportional to how much of the sensor rod is in the sensor tube.
Regasense is a part of Regal Components | Installation of sensor rod Pre-installation checklist Make sure that there is no damage to the sensor. • The sensor rod and tube shall be straight and intact without dents and scratches. •...
Page 6
Regasense is a part of Regal Components | Installation of sensor rod 1. Mount the o-ring and and back-up ring on the sensor header according to drawing below. Do not install the senor rod without o-ring and back-up ring. The sensor is not designed for hydraulic pressure on the backside of the sensor header.
Page 7
Regasense is a part of Regal Components | Installation of connector 6140 1. Place o-ring on connector. Recommended o-ring: 14 x 1,78 mm NBR70. Not included in scope of delivery. 2. Cut the sensor wires to suitable length. 3. Place heat shrink tube on the wires.
Page 8
Regasense is a part of Regal Components | Installation of connector 6160 6160 connectors can only be used when the sensor is pressure sealed at the header. 6160 consists of crimp contacts, splice ring, contact carrier and flange housing. When a RCL40 sensor is supplied with 6160 connector the crimp contacts is crimped to the sensor wires from factory.
Regasense is a part of Regal Components | Installation of control box General information Both RCL40 and RCL41 sensors can be used with both RCL41 and RCL43 control boxes. Choose the control box best suited for your application. RCL41 control box is designed for DIN mounting and RCL43 control box is designed with a sealed aluminium housing.
Regasense is a part of Regal Components | RCL41 - DIN Controller box Connect the control box and sensor according the schematic figure and choose preffered output con- figuration. Output signal and jumper settings The controllers have two parallel outputs; current and voltage.
Page 11
Regasense is a part of Regal Components | RCL43 - Aluminum Controller box Connect the control box and sensor according the schematic figure and choose preffered output con- figuration. Output signal and jumper settings The controllers have two parallel outputs; current and voltage.
Page 12
Regasense is a part of Regal Components | Comissioning Check that the controller and sensor are connected properly. Do not supply power to the controller until all wires or cables are connected properly for selected output. The sensor probe and the control box are calibrated before shipment. The output should be checked before and after mounting and is adjustable as described below.
This system is very robust and does usually work for many years of constant operation. However if there is a problem use this guide to troubleshoot if there is a sensor or controller malfunction. Note that repairs is not allowed. Contact Regal Components AB in case of malfunction. Sensor The sensor is simply put a winded coil.