Security Brands Edge 27-210 Direct Programming Manual

Security Brands Edge 27-210 Direct Programming Manual

Smart keypads and card readers
Table of Contents

Advertisement

Quick Links

27-210, 27-220HID/SK, 27-225HID/SK,
D I R E C T P R O G R A M M I N G M A N U A L
27-230HID/SK, 27-235HID/SK, 27-240

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Edge 27-210 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Security Brands Edge 27-210

  • Page 1 27-210, 27-220HID/SK, 27-225HID/SK, D I R E C T P R O G R A M M I N G M A N U A L 27-230HID/SK, 27-235HID/SK, 27-240...
  • Page 3 Edge SMART KEYPADs and Card Readers Direct Programming Manual Applicable Models 27-210, 27-220HID, 27-220SK, 27-225HID, 27-225SK, 27-230HID, 27-230SK, 27-235HID, 27-235SK, 27-240 © 2021 Security Brands, Inc. All rights reserved.
  • Page 5: Table Of Contents

    Edge Smart Keypads and Card Readers Direct Programming Manual Table of Contents Introduction _____________________________________________________________________________ 3 Overview __________________________________________________________________________________________________ 3 Glossary ___________________________________________________________________________________________________ 3 Programming ____________________________________________________________________________ 4 Direct Programming Input Format____________________________________________________________________ 4 Sub Modes Overview ____________________________________________________________________________________ 4 Default Configuration __________________________________________________________________________________ 5 Audible Tone Feedback _________________________________________________________________________________ 6 Programming Procedures ______________________________________________________________________________ 6 Add Access Code(s) to Relay A ___________________________________________________________________ 6 Delete Code ______________________________________________________________________________________ 6...
  • Page 6 Direct Programming Manual Edge Smart Keypads and Card Readers Add Latch Code(s) to Relay A on Both Wiegand Inputs _________________________________________ 32 Add Latch Code(s) to Relay A on Wiegand Input 1 _____________________________________________ 35 Add Latch Code(s) to Relay A on Wiegand Input 2 _____________________________________________ 37 Add Access Code(s) to Relay B on Both Wiegand Inputs _______________________________________ 39 Add Access Code(s) to Relay B on Wiegand Input 1 ____________________________________________ 41 Add Access Code(s) to Relay B on Wiegand Input 2 ____________________________________________ 44...
  • Page 7: Introduction

    Edge Smart Keypads and Card Readers Direct Programming Manual Introduction Overview This manual covers in detail how to carry out all programing functions on all Edge Smart Keypad and Card Reader systems directly via the onboard keypad. Glossary Access Card/Code A card/code used to trigger a relay for a configurable trigger time and open a gate or door.
  • Page 8: Programming

    Direct Programming Manual Edge Smart Keypads and Card Readers Programming Direct Programming Input Format All direct programming procedures involve entering the Master Code at the Edge unit to enter Programming Mode, entering the Sub Mode, entering additional Sub Modes (depending on feature), entering the parameter value(s), and pressing the pound key (#) to exit programming.
  • Page 9: Default Configuration

    Edge Smart Keypads and Card Readers Direct Programming Manual Configure Wiegand Bit Format on Wiegand Input 1 Configure Wiegand Bit Format on Wiegand Input 2 Configure Wiegand Code Scheme Configure Wiegand Validation Method Configure Wiegand Code Length Add Access Code(s) to Relay B Add Limited-Use Code Enter Pairing Mode Delete All Codes...
  • Page 10: Audible Tone Feedback

    Direct Programming Manual Edge Smart Keypads and Card Readers Audible Tone Feedback All Edge units produce audible tone feedback for key presses, correct entries, incorrect entries, and to confirm a cleared entry as detailed below. Audible feedback is also used for feature status/mode. Good Tone: sounds when a correct control or programming entry is received by the Edge unit.
  • Page 11: Change Master Code

    Edge Smart Keypads and Card Readers Direct Programming Manual Change Master Code This procedure will change the current Master Code. Note: By default, the following codes are reserved for other functions and cannot be used: 1251, 1273, 1366, 1381, 1387, 1678, 1752, and 1985. 1251 $ 3 $ XXXX $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 12: Change Code Length

    Direct Programming Manual Edge Smart Keypads and Card Readers 1251, 1273, 1366, 1381, 1387, 1678, 1752, and 1985. 1251 $ 4 $ 4 $ XXXX $ # Enter Master Code (default 1251) and listen for good tone. Enter sub mode 4 and listen for good tone. Enter secondary sub mode 4 and listen for good tone.
  • Page 13: Enable/Disable "3 Strikes, You're Out

    Edge Smart Keypads and Card Readers Direct Programming Manual Enter Master Code (default 1251) and listen for good tone. Enter sub mode 4 and listen for good tone. Enter secondary sub mode 7 and listen for audible feedback. Single tone means feature is enabled. Double tone means feature is disabled.
  • Page 14 Direct Programming Manual Edge Smart Keypads and Card Readers Four tones: Mode 4 enabled. Five tones: Mode 5 enabled. Enter 0 and listen for good tone. Enter # key to exit Programming Mode. Mode 1 When this mode is active, the selected relay will be triggered when the state of Event Input 1 changes from normally open (N/O) to normally closed (N/C).
  • Page 15 Edge Smart Keypads and Card Readers Direct Programming Manual Mode 3 This mode is a combination of Modes 1 and 2. 1251 $ 4 $ 9 $ 3 $ X $ # Enter Master Code (default 1251) and listen for good tone. Enter sub mode 4 and listen for good tone.
  • Page 16: Add Latch Code To Relay A

    Direct Programming Manual Edge Smart Keypads and Card Readers (The default configuration is Relay B trigger.) 1251 $ 4 $ 9 $ 5 $ X $ X $ # Enter Master Code (default 1251) and listen for good tone. Enter sub mode 4 and listen for good tone. Enter secondary sub mode 9 and listen for status tones: Good tone: Event Input 1 is disabled (Mode 0).
  • Page 17 Edge Smart Keypads and Card Readers Direct Programming Manual Enter sub mode 6 and listen for good tone. Enter next sub mode 100 and listen for good tone. Enter next sub mode 1 and listen for good tone. Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone. Repeat above step to add additional codes.
  • Page 18 Direct Programming Manual Edge Smart Keypads and Card Readers Enter Master Code (default 1251) and listen for good tone. Enter sub mode 6 and listen for good tone. Enter next sub mode 100 and listen for good tone. Enter next sub mode 3 and listen for good tone. Enter 3-digit facility code and listen for good tone.
  • Page 19: Add Access Code(S) To Relay A On Wiegand Input 1

    Edge Smart Keypads and Card Readers Direct Programming Manual Add Access Code(s) to Relay A on Wiegand Input 1 These procedures will add an access code or codes to Relay A for Wiegand keypads, card readers, remotes, and vehicle tag readers on Wiegand Input 1 only. Quick Entry for Wiegand Keypad (uses default facility code) This procedure will add one or more access codes with the default facility code for a Wiegand keypad.
  • Page 20 Direct Programming Manual Edge Smart Keypads and Card Readers Note: This procedure will not work if any of the following are true: Wiegand input is set to SBI Flex 64-bit format.  Wiegand input is disabled.  Wiegand input is configured to share code list with non-Wiegand codes. ...
  • Page 21: Add Access Code(S) To Relay A On Wiegand Input 2

    Edge Smart Keypads and Card Readers Direct Programming Manual Repeat above step to add additional codes. Note: Card-to-card swipe timeout is 10 seconds. Enter # key to exit Programming Mode. Note: This procedure will not work if any of the following are true: Wiegand input is set to SBI Flex 64-bit format.
  • Page 22 Direct Programming Manual Edge Smart Keypads and Card Readers Enter sub mode 6 and listen for good tone. Enter 2 (for Wiegand Input 2). No tone will sound. Enter next sub mode 100 and listen for good tone. Enter next sub mode 2 and listen for good tone. Enter 3-digit facility code and listen for good tone.
  • Page 23: Add Manager Access Code(S) To Relay A On Both Wiegand Inputs

    Edge Smart Keypads and Card Readers Direct Programming Manual Wiegand card reader or vehicle tag reader. Only the 26-bit format can be used. 1251 $ 6 $ 2 $ 100 $ 4 $ Scan First Card $ ... $ Scan Last Card $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 24 Direct Programming Manual Edge Smart Keypads and Card Readers One or both Wiegand inputs are disabled.  One or both Wiegand inputs are configured to share code list with non-Wiegand codes.  Each Wiegand input is configured to a different Wiegand bit format. ...
  • Page 25: Add Manager Access Code(S) To Relay A On Wiegand Input 1

    Edge Smart Keypads and Card Readers Direct Programming Manual One or both Wiegand inputs are set to SBI Flex 64-bit format.  One or both Wiegand inputs are disabled.  One or both Wiegand inputs are configured to share code list with non-Wiegand codes. ...
  • Page 26 Direct Programming Manual Edge Smart Keypads and Card Readers Enter next sub mode 101 and listen for good tone. Enter next sub mode 1. Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone. Repeat above step to add additional codes. Enter # key to exit Programming Mode.
  • Page 27: Add Manager Access Code(S) To Relay A On Wiegand Input 2

    Edge Smart Keypads and Card Readers Direct Programming Manual Enter next sub mode 101 and listen for good tone. Enter next sub mode 3 and listen for good tone. Enter 3-digit facility code and listen for good tone. Enter 5-digit starting manager access code and listen for good tone. Enter 5-digit ending manager access code and listen for good tone (maximum of 100 codes).
  • Page 28 Direct Programming Manual Edge Smart Keypads and Card Readers Quick Entry for Wiegand Keypad (uses default facility code) This procedure will add one or more manager access codes with the default facility code for a Wiegand keypad. Both the 26-bit and SBI Flex 64-bit formats can be used. 1251 $ 6 $ 2 $ 101 $ 1 $ XXXXX $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 29 Edge Smart Keypads and Card Readers Direct Programming Manual Bulk Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers This procedure will add manager access codes with a specified facility code in bulk for a Wiegand card reader, remote, or vehicle tag reader. Only the 26-bit format can be used. 1251 $ 6 $ 2 $ 101 $ 3 $ XXX $ XXXXX $ XXXXX $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 30: Add Sleep Code(S) On Both Wiegand Inputs

    Direct Programming Manual Edge Smart Keypads and Card Readers Wiegand input is configured to share code list with non-Wiegand codes.  Add Sleep Code(s) on Both Wiegand Inputs These procedures will add a sleep code or codes for Wiegand keypads, card readers, remotes, and vehicle tag readers on both Wiegand inputs.
  • Page 31 Edge Smart Keypads and Card Readers Direct Programming Manual One or both Wiegand inputs are set to SBI Flex 64-bit format.  One or both Wiegand inputs are disabled.  One or both Wiegand inputs are configured to share code list with non-Wiegand codes. ...
  • Page 32: Add Sleep Code(S) On Wiegand Input 1

    Direct Programming Manual Edge Smart Keypads and Card Readers Note: This procedure will not work if any of the following are true: One or both Wiegand inputs are set to SBI Flex 64-bit format.  One or both Wiegand inputs are disabled. ...
  • Page 33 Edge Smart Keypads and Card Readers Direct Programming Manual Enter next sub mode 2 and listen for good tone. Enter 3-digit facility code and listen for good tone. Enter 5-digit sleep code and listen for good tone. Repeat above step to add additional codes. Enter # key to exit Programming Mode.
  • Page 34: Add Sleep Code(S) On Wiegand Input 2

    Direct Programming Manual Edge Smart Keypads and Card Readers Enter Master Code (default 1251) and listen for good tone. Enter sub mode 6 and listen for good tone. Enter 1 (for Wiegand Input 1). No tone will sound. Enter next sub mode 102 and listen for good tone. Enter next sub mode 4 and listen for good tone.
  • Page 35 Edge Smart Keypads and Card Readers Direct Programming Manual Split relay feature is enabled.  Quick Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers This procedure will add one or more sleep codes with a specified facility code for a Wiegand card reader, remote, or vehicle tag reader.
  • Page 36: Add Latch Code(S) To Relay A On Both Wiegand Inputs

    Direct Programming Manual Edge Smart Keypads and Card Readers Wiegand input is set to SBI Flex 64-bit format.  Wiegand input is disabled.  Wiegand input is configured to share code list with non-Wiegand codes.  Split relay feature is enabled. ...
  • Page 37 Edge Smart Keypads and Card Readers Direct Programming Manual Enter next sub mode 1 and listen for good tone. Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone. Repeat above step to add additional codes. Enter # key to exit Programming Mode.
  • Page 38 Direct Programming Manual Edge Smart Keypads and Card Readers Enter sub mode 6 and listen for good tone. Enter next sub mode 103 and listen for good tone. Enter next sub mode 3 and listen for good tone. Enter 3-digit facility code and listen for good tone. Enter 5-digit starting latch code and listen for good tone.
  • Page 39: Add Latch Code(S) To Relay A On Wiegand Input 1

    Edge Smart Keypads and Card Readers Direct Programming Manual Add Latch Code(s) to Relay A on Wiegand Input 1 These procedures will add a latch code or codes to Relay A for Wiegand keypads, card readers, remotes, and vehicle tag readers on Wiegand Input 1 only. Quick Entry for Wiegand Keypad (uses default facility code) This procedure will add one or more latch codes with the default facility code for a Wiegand keypad.
  • Page 40 Direct Programming Manual Edge Smart Keypads and Card Readers Note: This procedure will not work if any of the following are true: Wiegand input is set to SBI Flex 64-bit format.  Wiegand input is disabled.  Wiegand input is configured to share code list with non-Wiegand codes. ...
  • Page 41: Add Latch Code(S) To Relay A On Wiegand Input 2

    Edge Smart Keypads and Card Readers Direct Programming Manual Repeat above step to add additional codes. Note: Card-to-card swipe timeout is 10 seconds. Enter # key to exit Programming Mode. Note: This procedure will not work if any of the following are true: Wiegand input is set to SBI Flex 64-bit format.
  • Page 42 Direct Programming Manual Edge Smart Keypads and Card Readers Enter sub mode 6 and listen for good tone. Enter 2 (for Wiegand Input 2). No tone will sound. Enter next sub mode 103 and listen for good tone. Enter next sub mode 2 and listen for good tone. Enter 3-digit facility code and listen for good tone.
  • Page 43: Add Access Code(S) To Relay B On Both Wiegand Inputs

    Edge Smart Keypads and Card Readers Direct Programming Manual Wiegand card reader or vehicle tag reader. Only the 26-bit format can be used. 1251 $ 6 $ 2 $ 103 $ 4 $ Scan First Card $ ... $ Scan Last Card $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 44 Direct Programming Manual Edge Smart Keypads and Card Readers One or both Wiegand inputs are configured to share code list with non-Wiegand codes.  Each Wiegand input is configured to a different Wiegand bit format.  Split relay feature is enabled. ...
  • Page 45: Add Access Code(S) To Relay B On Wiegand Input 1

    Edge Smart Keypads and Card Readers Direct Programming Manual Note: This procedure will not work if any of the following are true: One or both Wiegand inputs are set to SBI Flex 64-bit format.  One or both Wiegand inputs are disabled. ...
  • Page 46 Direct Programming Manual Edge Smart Keypads and Card Readers Enter sub mode 6 and listen for good tone. Enter 1 (for Wiegand Input 1). No tone will sound. Enter next sub mode 104 and listen for good tone. Enter next sub mode 1. Enter code (26-bit: 5 digits;...
  • Page 47 Edge Smart Keypads and Card Readers Direct Programming Manual Enter Master Code (default 1251) and listen for good tone. Enter sub mode 6 and listen for good tone. Enter 1 (for Wiegand Input 1). No tone will sound. Enter next sub mode 104 and listen for good tone. Enter next sub mode 3 and listen for good tone.
  • Page 48: Add Access Code(S) To Relay B On Wiegand Input 2

    Direct Programming Manual Edge Smart Keypads and Card Readers Add Access Code(s) to Relay B on Wiegand Input 2 These procedures will add an access code or codes to Relay B for Wiegand keypads, card readers, remotes, and vehicle tag readers on Wiegand Input 2 only. Quick Entry for Wiegand Keypad (uses default facility code) This procedure will add one or more access codes with the default facility code for a Wiegand keypad.
  • Page 49 Edge Smart Keypads and Card Readers Direct Programming Manual Note: This procedure will not work if any of the following are true: Wiegand input is set to SBI Flex 64-bit format.  Wiegand input is disabled.  Wiegand input is configured to share code list with non-Wiegand codes. ...
  • Page 50: Add Latch Code(S) To Relay B On Both Wiegand Inputs

    Direct Programming Manual Edge Smart Keypads and Card Readers Repeat above step to add additional codes. Note: Card-to-card swipe timeout is 10 seconds. Enter # key to exit Programming Mode. Note: This procedure will not work if any of the following are true: Wiegand input is set to SBI Flex 64-bit format.
  • Page 51 Edge Smart Keypads and Card Readers Direct Programming Manual Enter sub mode 6 and listen for good tone. Enter next sub mode 105 and listen for good tone. Enter next sub mode 2 and listen for good tone. Enter 3-digit facility code and listen for good tone. Enter 5-digit latch code and listen for good tone.
  • Page 52: Add Latch Code(S) To Relay B On Wiegand Input 1

    Direct Programming Manual Edge Smart Keypads and Card Readers Wiegand card reader or vehicle tag reader. Only the 26-bit format can be used. 1251 $ 6 $ 105 $ 4 $ Scan First Card $ ... $ Scan Last Card $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 53 Edge Smart Keypads and Card Readers Direct Programming Manual Wiegand input is disabled.  Wiegand input is configured to share code list with non-Wiegand codes.  Split relay feature is enabled.  Quick Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers This procedure will add one or more latch codes with a specified facility code for a Wiegand card reader, remote, or vehicle tag reader.
  • Page 54: Add Latch Code(S) To Relay B On Wiegand Input 2

    Direct Programming Manual Edge Smart Keypads and Card Readers Enter # key to exit Programming Mode. Note: This procedure will not work if any of the following are true: Wiegand input is set to SBI Flex 64-bit format.  Wiegand input is disabled. ...
  • Page 55 Edge Smart Keypads and Card Readers Direct Programming Manual Enter sub mode 6 and listen for good tone. Enter 2 (for Wiegand Input 2). No tone will sound. Enter next sub mode 105 and listen for good tone. Enter next sub mode 1. Enter code (26-bit: 5 digits;...
  • Page 56 Direct Programming Manual Edge Smart Keypads and Card Readers Enter Master Code (default 1251) and listen for good tone. Enter sub mode 6 and listen for good tone. Enter 2 (for Wiegand Input 2). No tone will sound. Enter next sub mode 105 and listen for good tone. Enter next sub mode 3 and listen for good tone.
  • Page 57: Change Default Facility Code

    Edge Smart Keypads and Card Readers Direct Programming Manual Change Default Facility Code These procedures will change the default facility code used for codes added on the Wiegand inputs. Wiegand 1 1251 $ 6 $ 1 $ 106 $ XXX $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 58 Direct Programming Manual Edge Smart Keypads and Card Readers Enter sub mode 6 and listen for good tone. Enter next sub mode 1. No tone will sound. Enter next sub mode 107 and listen for good tone. Enter next sub mode 1. Enter code (26-bit: 5 digits;...
  • Page 59: Add Split-Relay Latch Code On Wiegand Inputs

    Edge Smart Keypads and Card Readers Direct Programming Manual Enter # key to exit Programming Mode. Note: This procedure will not work if Wiegand input is set to SBI Flex 64-bit format. Scan Entry for Wiegand Card Readers and Vehicle Tag Readers This procedure will add one or more access codes with a specified facility code by scanning for a Wiegand card reader or vehicle tag reader.
  • Page 60 Direct Programming Manual Edge Smart Keypads and Card Readers Enter next sub mode 107 and listen for good tone. Enter next sub mode 1. Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone. Repeat above step to add additional codes. Enter # key to exit Programming Mode.
  • Page 61: Delete Code(S) On Both Wiegand Inputs

    Edge Smart Keypads and Card Readers Direct Programming Manual Scan Entry for Wiegand Card Readers and Vehicle Tag Readers This procedure will add one or more latch codes with a specified facility code by scanning for a Wiegand card reader or vehicle tag reader. Only the 26-bit format can be used. 1251 $ 6 $ 2 $ 107 $ 4 $ Scan First Card $ ...
  • Page 62 Direct Programming Manual Edge Smart Keypads and Card Readers Quick Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers This procedure will delete one or more codes with a specified facility code for a Wiegand card reader, remote, or vehicle tag reader. 1251 $ 6 $ 200 $ 2 $ XXX $ XXXXX $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 63: Delete Code(S) On Wiegand Input 1

    Edge Smart Keypads and Card Readers Direct Programming Manual One or both Wiegand inputs are configured to share code list with non-Wiegand codes.  Each Wiegand input is configured to a different Wiegand bit format.  Split relay feature is enabled. ...
  • Page 64 Direct Programming Manual Edge Smart Keypads and Card Readers Enter code (26-bit: 5 digits; numbers only; max value 65535) and listen for good tone. Repeat above step to add additional codes. Enter # key to exit Programming Mode. Note: This procedure will not work if any of the following are true: Wiegand input is disabled.
  • Page 65: Delete Code(S) On Wiegand Input 2

    Edge Smart Keypads and Card Readers Direct Programming Manual Enter next sub mode 3 and listen for good tone. Enter 3-digit facility code and listen for good tone. Enter 5-digit starting code and listen for good tone. Enter 5-digit ending code and listen for good tone (maximum of 100 codes). Enter # key to exit Programming Mode.
  • Page 66 Direct Programming Manual Edge Smart Keypads and Card Readers Quick Entry for Wiegand Keypad (uses default facility code) This procedure will delete one or more codes for a Wiegand keypad. 1251 $ 6 $ 2 $ 200 $ 1 $ XXXXX $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 67 Edge Smart Keypads and Card Readers Direct Programming Manual Bulk Entry for Wiegand Card Readers, Remotes, and Vehicle Tag Readers This procedure will delete codes with a specified facility code in bulk for a Wiegand card reader, remote, or vehicle tag reader. 1251 $ 6 $ 2 $ 200 $ 3 $ XXX $ XXXXX $ XXXXX $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 68: Set Unit Clock Time

    Direct Programming Manual Edge Smart Keypads and Card Readers Wiegand input is disabled.  Wiegand input is configured to share code list with non-Wiegand codes.  Split relay feature is enabled.  Set Unit Clock Time This procedure will set the clock on the Edge unit. 1251 $ 6 $ 302 $ XX (Hours) $ XX (Minutes) $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 69 Edge Smart Keypads and Card Readers Direct Programming Manual Each Wiegand input is configured to a different Wiegand bit format.  Each Wiegand input is configured for SBI Flex 64-bit format but with different code lengths.  Each Wiegand input is configured for a different Wiegand device type. ...
  • Page 70: Toggle Silent Mode

    Direct Programming Manual Edge Smart Keypads and Card Readers Enter Master Code (default 1251) and listen for good tone. Enter sub mode 6 and listen for good tone. Enter next sub mode 307 and listen for status tones: Good tone: Split-relay function disabled One tone: Mode 1 enabled...
  • Page 71 Edge Smart Keypads and Card Readers Direct Programming Manual Note: Enabling anti-passback while split-relay functionality is enabled may cause some undesirable effects. Note: The procedures involving Wiegand inputs will not work if the Wiegand inputs involved are disabled. Disable Anti-Passback This procedure will disable anti-passback.
  • Page 72 Direct Programming Manual Edge Smart Keypads and Card Readers followed by a device on Wiegand Input 1 or 2. 1251 $ 6 $ 310 $ 3 $ # Enter Master Code (default 1251) and listen for good tone. Enter sub mode 6 and listen for good tone. Enter next sub mode 310 and listen for good tone.
  • Page 73: Configure Wiegand Inputs

    Edge Smart Keypads and Card Readers Direct Programming Manual Enter next sub mode 9 and listen for status tones: Good tone: Anti-passback disabled One tone: Timed lockout enabled Two tones: Scheme A enabled Three tones: Scheme B enabled Four tones: Scheme C enabled Enter # key to exit Programming Mode.
  • Page 74: Configure Wiegand Bit Format

    Direct Programming Manual Edge Smart Keypads and Card Readers Enter 3 to enable as remote and listen for good tone. Enter # key to exit Programming Mode. Configure Wiegand Bit Format These procedures will configure the Wiegand bit format for Wiegand codes. IMPORTANT! COMPLETING THESE PROCEDURES WILL DELETE ALL WIEGAND CODES! ...
  • Page 75: Configure Wiegand Code Scheme

    Edge Smart Keypads and Card Readers Direct Programming Manual Configure Wiegand Code Scheme These procedures will configure the scheme to be followed for Wiegand codes. Wiegand codes can be set to exist as standard keypad codes as well or to be kept separate on a different list. IMPORTANT! COMPLETING THESE PROCEDURES WILL DELETE ALL WIEGAND CODES! ...
  • Page 76: Configure Wiegand Validation Method

    Direct Programming Manual Edge Smart Keypads and Card Readers Configure Wiegand Validation Method These procedures will configure the validation method used on the Wiegand inputs. Wiegand Input 1 1251 $ 6 $ 1 $ 505 $ X $ # Enter Master Code (default 1251) and listen for good tone. Enter sub mode 6 and listen for good tone .
  • Page 77: Add Access Code(S) To Relay B

    Edge Smart Keypads and Card Readers Direct Programming Manual Enter length value (04 to 11) and listen for good tone. Enter Master Code (default 1251) again and listen for good tone. Enter # key to exit Programming Mode. Wiegand Input 2 This procedure will set the code length for Wiegand Input 2 1251 $ 6 $ 2 $ 506 $ XX $ 1251 $ # Enter Master Code (default 1251) and listen for good tone.
  • Page 78: Enter Pairing Mode

    Direct Programming Manual Edge Smart Keypads and Card Readers Enter Master Code (default 1251) and listen for good tone. Enter sub mode 8 and listen for good tone. Enter 1 for use restriction or 2 for time restriction and listen for good tone. Enter the code with configured length and listen for good tone.
  • Page 79: Unit Reset

    Edge Smart Keypads and Card Readers Direct Programming Manual Unit Reset This procedure will reset the Edge unit back to factory settings, erasing the codes and timers in memory and resetting the Master Code back to the default value. IMPORTANT! THIS PROCEDURE WILL RESET THE EDGE UNIT TO FACTORY SETTINGS AND ...
  • Page 80 • 7-day, 365-day, holiday, and special event timers (separate timers for each relay) • Random code generator • Event reports with CSV export • • • Quick cloning for multiple-unit setups (972) 474-6390 securitybrandsinc.com © 2021 Security Brands, Inc. All rights reserved. M-27X-01-EN Rev. B (2/2021)

Table of Contents