Klimawent ALAN-U/E-10-HD-N Use And Maintenance Manual

Reel exhaust extractor

Advertisement

Quick Links

EN
USE AND MAINTENANCE MANUAL
Reel Exhaust Extractor ALAN-U/E-HD-N
INTRODUCTION ......................................................................................................................................................... 2
PURPOSE ................................................................................................................................................................... 2
RESERVATIONS OF MANUFACTURER .................................................................................................................. 2
TECHNICAL DATA ..................................................................................................................................................... 2
STRUCTURE AND FUNCTION ................................................................................................................................. 4
ASSEMBLY AND STARTUP ..................................................................................................................................... 4
OPERATIONAL USE ................................................................................................................................................... 7
TROUBLESHOOTING GUIDE .................................................................................................................................... 8
MAINTENANCE ........................................................................................................................................................... 8
OCCUPATIONAL HEALTH AND SAFETY ................................................................................................................ 8
TRANSPORT AND STORAGE ................................................................................................................................. 9
TERMS OF WARRANTY ........................................................................................................................................... 9
DECLARATION OF CONFORMITY ........................................................................................................................ 10
Producer: KLIMAWENT S.A.
81-571 Gdynia, ul. Chwaszczyńska 194
tel. 58 629 64 80, 58 771 43 40
fax 58 629 64 19
email:
klimawent@klimawent.com.pl
www.klimawent.com.pl
(electrical drive)
Contents:
May 2019
issue:

Advertisement

Table of Contents
loading

Summary of Contents for Klimawent ALAN-U/E-10-HD-N

  • Page 1: Table Of Contents

    OCCUPATIONAL HEALTH AND SAFETY ........................ 8 TRANSPORT AND STORAGE ..........................9 TERMS OF WARRANTY ............................9 DECLARATION OF CONFORMITY ........................10 Producer: KLIMAWENT S.A. 81-571 Gdynia, ul. Chwaszczyńska 194 tel. 58 629 64 80, 58 771 43 40 fax 58 629 64 19 email: klimawent@klimawent.com.pl...
  • Page 2: Introduction

    Klimawent – the warranty of highest quality at attractive price INTRODUCTION The purpose of the present Use and Maintenance Manual is to supply User with directions within the range of application, assembly, start-up and operational use of the ALAN-U/E-HD-N Reel Exhaust Extractor.
  • Page 3 Klimawent – the warranty of highest quality at attractive price Table No.2 – Technical Data – FA fans mounted directly to the exhaust reel Type Supply Diameter Motor rate Acoustic Weight voltage inlet / outlet pressure level [mm] [kW] [dB(A)]*...
  • Page 4: Structure And Function

    Klimawent – the warranty of highest quality at attractive price STRUCTURE AND FUNCTION The Reel Exhaust Extractor consists of a winding reel installed in a framework (adapted for mounting under the ceiling or on a wall). Onto the reel is wound a hose with a nozzle. Nozzles are adapted to the diameter of the hoses (and selected to the Customer’s requirements) and are delivered upon separate order.
  • Page 5 Klimawent – the warranty of highest quality at attractive price INSTALLING OF THE FAN TYPE FA: The fan has to be installed to the left wall of the framework. Following steps of installing: put a sealing ring on the outlet connection of the reel extractor in the bottom part, screw up 2 mounting bolts to fasten the solid bush to the left wall;...
  • Page 6 Klimawent – the warranty of highest quality at attractive price Having installed the extractor under the ceiling or at the wall, connect the reel outlet (in application without the built-on fan) with the round section ventilation conduit, to discharge the exhaust volume out of the process room.
  • Page 7: Operational Use

    Klimawent – the warranty of highest quality at attractive price Fig. No.6 – Connection Diagram – Control unit and 3x400V supply OPERATIONAL USE The ZE-ALAN-U/E control unit serves to switch on and off the fan and to control the hose coiling/recoiling. The motor switch protects the fan motor from overload and short-circuit, non-complete-phase work and start-up- blocking.
  • Page 8: Troubleshooting Guide

    Klimawent – the warranty of highest quality at attractive price For safety reasons, in order to use the Reel Exhaust Extractor correctly – follow subsequent steps: Start the extraction fan using the motor disconnector Q1 in the ZE-ALAN-U/E control unit (black button).
  • Page 9: Transport And Storage

    Klimawent – the warranty of highest quality at attractive price Maintenance Manual. Connection to the power system ought to be executed by a person of electrical qualifications and in compliance with the valid safety regulations. The fan motor has to be connected to the electrical wiring system – according to the present regulations within the range of personnel protection from electric shock and short-circuit- overload effects.
  • Page 10: Declaration Of Conformity

    Klimawent – the warranty of highest quality at attractive price DECLARATION OF CONFORMITY DECLARATION OF CONFORMITY EC No . _______________ Manufacturer (eventually also the authorised representative / importer): name: KLIMAWENT S.A. address: 81-571 GDYNIA, ul. Chwaszczyńska 194 A person, authorised for issuing the technical documentation: name and address: Teodor Świrbutowicz, KLIMAWENT S.A.
  • Page 11 Klimawent – the warranty of highest quality at attractive price NOTES: 24.05.2019 Reel Exhaust Extractor ALAN-U/E-HD-N 11 z 12...
  • Page 12 Klimawent – the warranty of highest quality at attractive price NOTES: Reel Exhaust Extractor ALAN-U/E-HD-N 12 z 12 24.05.2019...

This manual is also suitable for:

Alan-u/e-15-hd-nAlan-u/e-22-hd-n

Table of Contents