COBRA Bailout System
23 May 2019
Page 1 of 3
ADVISORY NOTICE
Background
A client reported water ingress
to the COBRA scrubber. Their
own investigations discovered the
cause to be excessive hot water
pressure due to an incorrectly
set relief valve in the COBRA hot
water system.
ISSUE
Water ingress to COBRA scrubber
A client reported water ingress to the scrubber on a COBRA set. JFD inititally replaced the
Hot Water Housing (as it was thought the fault occurred in this component) but the clients own
investigations revealed an incorrectly set hot water PRV. The incorrectly set PRV failed to protect
the COBRA set from excessive hot water pressure and this caused the inner liner of the hot water
housing to deform and lose contact with the sealing o-ring. As a result hot water leaked into the
scrubber housing.
SOLUTION
Following a thorough review and investigation of the hot water PRV, JFD recommend
resetting the relief valve to open at 3 psi (rather than 4 psi as previously advised in the manual) and
checking the setting fortnightly thereafter.
Please see following pages for procedure.
Copyright © JFD Limited 2019
DB500-PGN-2
jfdglobal.com
enquiries@jfdglobal.com

Advertisement

loading

Summary of Contents for JFD COBRA

  • Page 1 PRV. The incorrectly set PRV failed to protect the COBRA set from excessive hot water pressure and this caused the inner liner of the hot water housing to deform and lose contact with the sealing o-ring. As a result hot water leaked into the scrubber housing.
  • Page 2 Fit the test plug (DB5003843), test nut (DB5003844) and o-ring (E13330) to the hot water relief valve DB5002335 as shown in figure 1. These items are contained in the COBRA Tool and Test Kit. Fit a 3/8” UNF plug to the outlet of the relief valve.
  • Page 3 JFD are currently undertaking work to improve the flow capacity of the relief valve. This will ensure that the COBRA set is protected from overpressure, even if the COBRA set hot water outlet is totally blocked for any reason. A further guidance note and replacement parts will be issued in the near future to allow clients to carry out this modification.