Gastester Digital Supplementary adjustment procedure Part No. G4125 Instructions Guarantee If this product fails through faulty materials or workmanship, contact our service department direct on: +44 (0) 1926 818186. Normal wear and tear are excluded as are consumable items and abuse. Distributed by The Tool Connection Ltd Kineton Road, Southam, Warwickshire CV47 0DR T +44 (0) 1926 815000 F +44 (0) 1926 815888...
Page 2
Warning: do not touch or adjust controls A and B. Fig. 3. G4125 4. Connect up the Gastester and allow the reading to stabilise. Allow the tool to fully warm up for a Supplementary adjustment procedure minimum of 5 minutes. NB: During the adjustment process ensure the pump unit and circuit board remain still and vertical The procedure described below should only be used when the Gastester cannot be adjusted...