Advertisement

Quick Links

Manufactured For: Genesis Biotech Pty Ltd.
Level 1, 16 McDougall Street, MILTON QLD 4064
www.mylifesmart.net.au
AUSTRALIA & NEW ZEALAND -
support@mylifesmart.net.au
Australia: Ph 1300 110 155
(AEST - Mon-Fri, 11 am - 4 pm)
Distributed in Australia & New Zealand by:
Biotech Pty Ltd., QLD, Australia.
Distributed in India by: LifeSmart Healthcare Pvt. Ltd,
India Support: support@mylifesmart.net
Guangdong Transtek Medical Electronics Co., Ltd.
Zone A, No.105 ,Dongli Road, Torch Development District,
Zhongshan,528437,Guangdong,China
技术要求:
1、黏合不可露胶
2、保持印刷面板上的清洁
3、注意套印的准确性
4、表面处理不可爆开
5、结构工艺以结构受控图为准
6、颜色参考:
产品型号
LS808-BS-027
产品名称
血压计
对应结构图纸
材质
70g书写纸
尺寸
100*140 mm
单黑
印色
-
1:1
表面处理
-
李秋燕 2020-10-27
罗佳钰 2020-10-27
谭文昊 2020-10-27
User Manual
Blood Pressure Monitor
Thank you very much for selecting LifeSmart Blood Pressure
Monitor LS-926.
Please read the user manual carefully and thoroughly so as to ensure
the safe usage of this product, Keep the manual well for your further
reference in case you have problems.
PO#2B6526-LS808-BS-027-GB-05-说明书-A1
LS808-BS-027-GB-05
共 18 张
Version:1.0
LS-926
Arm Type
2020-10-27
第 1 张
A/1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LS-926 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for lifeSMART LS-926

  • Page 1 Australia: Ph 1300 110 155 (AEST - Mon-Fri, 11 am - 4 pm) Distributed in Australia & New Zealand by: Thank you very much for selecting LifeSmart Blood Pressure Biotech Pty Ltd., QLD, Australia. Distributed in India by: LifeSmart Healthcare Pvt. Ltd, Monitor LS-926.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Table of Contents INTRODUCTION ..............2 General Description Indications for Use Contraindications Measurement Principle Safety Information LCD Display Signal Monitor Components List BEFORE YOU START ............9 Power Supply and Charge Power Setting the Time,Date Pair-up the Blood Pressure Monitor with Your Device Tie the Cuff MEASUREMENT ...............
  • Page 3: Introduction

    The design provides you with two They are the requirement of standard and using. years of reliable service. Symbol for “TYPE BF APPLIED Readings taken by the LS-926 are equivalent to those obtained by a Symbol for “THE OPERATION PARTS” GUIDE MUST BE READ”...
  • Page 4 INTRODUCTION INTRODUCTION CAUTION CAUTION * This device is intended for adult use in homes only. * The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER was * The device is not suitable for use on neonatal patients, pregnant women,patients with clinically investigated according to the requirements of ISO 81060-2:2013. implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial * To verify the calibration of the AUTOMATED SPHYGMOMANOMETER, please contact the fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or...
  • Page 5: Lcd Display Signal

    Blood Pressure * If you have any problems with this device, such as setting up, maintaining or using, please Diastolic contact the SERVICE PERSONNEL of LifeSmart . Don’t open or repair the device by Low blood pressure Blood Pressure yourself in the event of malfunctions. The device must only be serviced, repaired and opened by individuals at authorized sales/service centers.
  • Page 6: Monitor Components

    (Type BF applied part) 3 Pump CAUTION 4 Valve The battery of LS-926 is built-in rechargeable lithium-ion battery, please 5 Cuff do not disassemble it by the unauthorized maintenance personel. Under the normal using, it can charge power about 300 times, if the...
  • Page 7: Setting The Time,Date

    BEFORE YOU START BEFORE YOU START CAUTION • Do not attempt to replace your blood pressure monitor’s battery. It is built-in and not changeable. • Only charge the battery in accordance with the user instructions supplied with the blood pressure monitor. •...
  • Page 8: Pair-Up The Blood Pressure Monitor With Your Device

    BEFORE YOU START BEFORE YOU START (3) Press “User 1” button again to confirm [YEAR]. Then the numeral (5) Repeat step 2 and 3 to confirm [HOUR] and [MINUTE]. representing [MONTH] blinks. (6) After confirming the [HOUR] and [MINUTE], the LCD will display (4) Repeat step 2 and 3 to confirm [MONTH ] and [DAY ].
  • Page 9 Interference may occur in the vicinity of equipment marked with the following symbol . And LS-926 may interfering vicinity electrical equipment. Sensitive people, including pregnant women pre-eclamptic and those who 4.Then please select the user ID you want to connect with your implanted medical electronic instruments, should avoid using the unit smartphone on the app to continute the pair-up.
  • Page 10: Tie The Cuff

    BEFORE YOU START MEASUREMENT Tie the Cuff Start Measurement Remove all accessories (watch, bracelet,etc) from your arm. If your physician has When the monitor is off, press User 1 button to turn diagnosed you with poor circulation in your arm, use the other one. on the monitor and it will finish the whole measurement, Roll or push up your sleeve to expose the skin.
  • Page 11: Data Management

    DATA MANAGEMENT MEASUREMENT Display and save the results. Inflating and measuring. Recall the Records The data transmission will proceed. The symbo will blink during the (1) When the monitor is off, please press the “Query” button to transmission. show the average value of the latest three records. If the records are less than three groups,it will display the latest record first.
  • Page 12: Delete The Records

    DATA MANAGEMENT DATA MANAGEMENT (3) When in the User1 memory mode, press the User 1 button to turn Delete the Records off the device, or press User 2 button to enter in User2 memory mode. (1) Hold pressing “Query” button for 3 seconds when the monitor is in the memory recall mode , the “dEL ALL+User ID”...
  • Page 13: Information For User

    INFORMATION FOR USER INFORMATION FOR USER Maintenance Tips for Measurement To obtain the best performance, please follow instructions below. Avoid immersing it in the water. Within 1 hour Immediate measurement Put in a dry place and avoid the sunshine Clean it with a dry cloth in case. after dinner or drinking after tea, coffee, smoking Avoid dusty environment and...
  • Page 14: About Blood Pressure

    ABOUT BLOOD PRESSURE ABOUT BLOOD PRESSURE Why does my blood pressure What are systolic pressure and diastolic pressure? fluctuate throughout the day? When ventricles contract and pump blood out Systolic Diastolic of the heart, the blood pressure reaches its blood discharging blood entering maximum value in the cycle, which is called 1.
  • Page 15: Troubleshooting

    TROUBLESHOOTING SPECIFICATIONS This section includes a list of error messages and frequently 3.7V 1000mAH Built-in rechargeable Power supply asked questions for problems you may encounter with your blood li-polymer battery, 6V 1A AC Adaptor pressure monitor. If the products not operating as you think it Digital LCD display Display mode V.A.= 86.1mm(L) x24mm(W)
  • Page 16: Athorized Component

    EN 1060-4:2004 Non-invasive sphygmomanometers - Part 4: Test procedures to determine the overall system accuracy of automated Clinical investigation non-invasive sphygmomanometers LS-926 ISO 81060-2:2013 Non-invasive sphygmomanometers - Part 2: Clinical validation of automated measurement type EN 60601-1-6:2010+A1:2015/IEC 60601-1-6:2010+A1:2013 Medical electrical equipment - Part 1-6: General requirements for basic...
  • Page 17 EMC GUIDANCE EMC GUIDANCE EMC GUIDANCE EMC GUIDANCE EMC Guidance Table 2 The ME EQUIPMENT or ME SYSTEM is suitable for home healthcare environments Guidance and manufacturer’s declaration – electromagnetic Immunity Warning:Don’t near active HF surgical equipment and the RF shielded room of an ME system for magnetic Immunity Test IEC 60601-1-2 Compliance level...
  • Page 18 EMC GUIDANCE EMC GUIDANCE Table 3 Guidance and manufacturer’s declaration - electromagnetic Immunity IMMUNITY Radiated RF Test Band Service Modulation Modulation Distance (m) TEST IEC61000-4-3 Frequency (MHz) LEVEL (Test (MHz) (V/m) specifications 380-390 TETRA Pulse ENCLOSURE modulation b) PORT 18Hz IMMUNITY to GMRS 460,...