M0026 has been engineered to satisfy the demand of big service stations and alternator repair shops for the device which would allow quick and accurate rectifier health checks. Testing rectifiers with the use of multimeter has always been the most common practice.This method has a significant...
English User Manual - M0026 Tester 2. TECHNICAL CHARACTERISTICS 219×214×80 Dimensions (L*W*H), mm Weight, kg Supply voltage, V Supply frequency, Hz Single-phase Supply type No more than 40 Consuming power, W Current load of diode test, A The voltage on the open contact probes of the device, V 3.
-cable with a probe – 1 pc., -cable with a clamp – 1 pc., -User Manual – 1 pc. Inspect M0026 tester. If any damage is detected, please contact the manufacturer or sales representative before launching the equipment. WARNING! In case of obvious damage, the operation of the device is forbidden.
English User Manual - M0026 Tester Fig.2. Diagnostic cables Fig.3. M0026 tester. Back view: 1 – Diode fuse; 2 – Power connector. 5. OPERATION OF THE DEVICE 1.Use the device as intended. 2.The tester is intended for indoor use. When used outdoors, external conditions and technical characteristics of the device set out in item 2 of this manual, should be taken into consideration.
In case of obvious damage, replace them with the new ones before launching the device. 5.2. Rectifier testing Diagnostics of a rectifier should be performed as follows: 1.Turn the tester on. Connect the clamp to the rectifier housing. The following message will appear on the screen: “CONNECT PROBE TO DIODE”.
Page 9
English User Manual - M0026 Tester 2.1. If the diode is faultless, the screen will display “Vf” and “Vr” values. The screen color will be green. 2.2. If the "Vf” value is higher than normal, the screen color will be yellow.
English User Manual - M0026 Tester 5.3. Tester setup The device assesses the diode performance on the basis of the forward voltage drop value (“Vf”) and is specially calibrated to make it usable for any operator who doesn’t have sufficient knowledge of the diode parameters and characteristics.
•Whether the measuring probes are in healthy condition (visual inspection). •Do not store or use the device in premises where there is a high temperature, humidity, danger of explosion or fire, strong magnetic field. As a result of exposure to dampness, the tester performance may deteriorate.
European WEEE Directive 2002/96/EC (Waste Electrical and Electronic Equipment Directive) applies to M0026 disposal. Obsolete electronic equipment and electric appliances including cables and hardware as well as batteries and accumulators must be disposed of separately from the household rubbish. Use available waste collection systems to dispose of outdated equipment.
Page 14
Produced by 18 Biolohichna St. 61030 Kharkiv, Ukraine +38 (057) 728 0171 Technical Support: support@servicems.eu General Enquiries: sales@servicems.eu Skype: MSG Equipment servicems.eu...
Need help?
Do you have a question about the M0026 and is the answer not in the manual?
Questions and answers