Electrical Connection - Summit CR2110B User Manual

Ceramic glass electric cooktop
Table of Contents

Advertisement

Available languages

Available languages

Model Number
CR2110WHE
CR2110B
CR2220WHE
CR2220B
The supply must be from an individual grounded circuit that is protected by a circuit breaker and
rated per the specifications for the various models as shown in the table above.
Consult with a licensed electrician before proceeding with the installation if the electrical power
supply does not meet the product specifications,
CAUTION: Installations must comply with all local, state, and national electrical codes. Failure to
comply with the applicable codes may result in fire, property damage, personal injury, or
death.

Electrical Connection

Before installing your cooktop, disconnect the power supply. Verify that the appropriate electrical
supply requirements have been met. Refer to the table above for the appropriate electrical
requirements.
The cooktop is supplied with a 40" long power cable to connect to an accessible junction box.
The conduit consists of three insulated wires.
In 120V units, there is a hot lead conductor (black insulated tinned copper), one insulated
o
ground conductor (green insulated tinned copper) and a neutral conductor (red or white
insulated tinned copper).
In 240V units, there is a hot lead conductor (black insulated tinned copper), one insulated
o
ground conductor (green insulated tinned copper) and a neutral conductor (red or white
insulated tinned copper).
Attach conductor wires to residence wiring in accordance with national, state and local electric
codes.
The entire appliance must be grounded at all times when the electrical power supply is on.
Connect the red to red, black to black and green to ground. Do not ground the appliance with
the neutral house supply wire. A separate ground must be used.
Max. Connected Load
2,400 Watts
2,400 Watts
2,400 Watts
2,400 Watts
WARNING
6
Required Power
Min. Wire Size
Supply Input
120V
AC/20A/50-60Hz
120V
AC/20A/50-60Hz
240V
AC/10A/50-60Hz
240V
AC/10A/50-60Hz
#16 AWG
#16 AWG
#16 AWG
#16 AWG