OPERATION AND SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE THIS PRODUCT.
INTRODUCTION
The Dual-Force Vac pulls liquids into and empties liquids from a sealed 55 gallon drum. The compressed air powered
pump is used for handling sludge, used coolant (complete with metal chips), hydraulic oil, tramp oil or solvents.
Liquids can be pulled from milling machines, lathes, EDM machines, sumps, parts washers, open pits or chemical
processes, etc.
COMPRESSED AIR SUPPLY
The compressed air supply must be filtered (5 micron maximum) to remove water and dirt. Vortec's #701S-24A
Compressed Air Filter is supplied for this purpose. If oil is present in the compressed air supply, remove the oil using a
0.01 micron (maximum) air filter. Use Vortec oil filter #701S-48, sold separately. Change filter elements as needed.
Operating pressure at the Dual-Force Vac should be 60 to 100 PSIG.
NOTE: Do not exceed air supply pressures over 100 PSIG when operating the Dual-Force Vac.
LIMITED WARRANTY
Vortec compressed air products manufactured by ITW Air Management will be replaced or repaired if found to be
defective due to manufacture within ten years from the date of invoice. Refer to our website itwvortec.com for
complete warranty details and limitations. ITW Air Management makes no specific warranty of merchantability or
warrant of fitness for a particular purpose.
1.
The closed head steel drum must be in "as new" condition and meet the requirements of UN1A1/X1.8/300.
2.
Operating the Dual-Force Vac at compressed air pressures above 60 PSIG requires the use of a drum consisting entirely of 16 gauge
steel or stronger.
3.
Do not operate the Dual-Force Vac at compressed air pressures above 100 PSIG (6.9 Bar).
4.
Do not operate the Dual-Force Vac at line temperatures above 110°F (43°C).
5.
DANGER: Do not operate the Dual-Force Vac with flammable or volatile liquids such as gasoline, alcohol, kerosene, aviation fuel,
mineral spirits or any material that has a low flash point.
6.
Do not operate the Dual-Force Vac without the gold cap assembly in place secured by the three screws. Operating without the three
screws in place could result in a hazardous situation.
7.
Do not operate the Dual-Force Vac without the float valve assembly installed between the pump body and the drum.
8.
Do not restrict or block the discharge flow of liquid out of the conveying hose.
9.
Avoid direct contact with compressed air; do not direct compressed air at any person.
10. When using compressed air, wear safety glasses with side shields.