Wallgate e-Suite Tap Product Manual

Traditional tap with electronic control

Advertisement

Quick Links

Product Manual
e-Suite Tap
Traditional Tap with
Electronic Control

Advertisement

Table of Contents
loading

Summary of Contents for Wallgate e-Suite Tap

  • Page 1 Product Manual e-Suite Tap Traditional Tap with Electronic Control...
  • Page 2 Product Manual e-Suite Tap Revision 3...
  • Page 3: Table Of Contents

    3. Glossary ..........................6 4. Overview ..........................7 5. Package Contents ......................7 5.1 Mounting Guidelines ......................8 5.2 e-Suite Tap disassembly ....................15 5.3 e-Suite Tap installation ....................16 5.4 Water Connections ......................17 5.5 Fitting the electronic encoder housing ................18 5.6 Mounting the WDC ......................
  • Page 4: Disclaimer

    Every effort has been made to supply information within this manual which is correct. Wallgate Limited will not be liable for any damage or loss that arises if the person installing, operating or maintaining the unit has not read or not complied with the manual In any event, and without prejudice to any warranties in Wallgate Limited’s terms and...
  • Page 5: Conventions

    A warning with white text on a red background is used to give information about hazards that can cause injury or death. Read and understand these warnings before you install and commission the e-Suite Tap. Failure to heed these warnings can have serious consequences.
  • Page 6: Glossary

    Product Manual e-Suite Tap 3. Glossary The glossary lists all words, abbreviations and technical terminology used in this manual, along with a short description of these terms. Term Description Encoder Housing The tap electronics fitted in a plastic housing attached to the bottom of the tap.
  • Page 7: Overview

    Product Manual e-Suite Tap 4. Overview The e-Suite Tap is a pillar tap of traditional appearance, which provides electronic control of water flow, when used in conjunction with a Wallgate WDC100/200e electronic controller. The use of the tap with an electronic controller allows a range of adjustable, automatic functions as detailed in the controller product manual;...
  • Page 8: Mounting Guidelines

    Product Manual e-Suite Tap 5.1 Mounting Guidelines • The e-Suite Tap is designed to be mounted on a Wallgate vanity top or basin but is compatible with many others. If the tap is to be used with a non Wallgate basin, ensure there is sufficient space for the water connections to the tap;...
  • Page 9 Product Manual e-Suite Tap Figure 1: e-Suite Tap details Revision 3...
  • Page 10 Product Manual e-Suite Tap Figure 2: e-Suite Tap & controls typical installation layout. Revision 3...
  • Page 11 Product Manual e-Suite Tap Figure 3: e-Suite Tap & controls typical installation layout. Revision 3...
  • Page 12 Product Manual e-Suite Tap Figure 4: e-Suite Tap & controls typical installation layout. Revision 3...
  • Page 13 Product Manual e-Suite Tap Figure 4: e-Suite Tap & controls typical installation layout Revision 3...
  • Page 14 Product Manual e-Suite Tap Figure 6: e-Suite Tap components and encoder housing fit. Revision 3...
  • Page 15: E-Suite Tap Disassembly

    Product Manual e-Suite Tap 5.2 e-Suite Tap disassembly 1 Loosen anti-rotation grub screw 2.1 Using a Tectite removal tool, remove the Tectite Tee from the tap connector. Then remove the tap connector from the bottom of the tap. 2.2 Undo the tap connector nut, pull the fittings sub-assembly away from the bottom of the tap.
  • Page 16: E-Suite Tap Installation

    Product Manual e-Suite Tap 5.3 e-Suite Tap installation NOTE: The installation procedure is shown on a vanity top but also applies when fitting the tap to a basin. Refer to Figure 3 in conjunction with the installation procedure below: Install the tap as follows: 1.
  • Page 17: Water Connections

    NOTE: Fit a service isolating tap on the water supply feed to each water solenoid valve. This allows for ease of maintenance when required. The isolating tap is not supplied by Wallgate, and should be purchased separately. NOTE: Use of any pipe sealing compound should be avoided to prevent blockages &...
  • Page 18: Fitting The Electronic Encoder Housing

    Product Manual e-Suite Tap 5.5 Fitting the electronic encoder housing The electronic encoder housing (item 9) has a plastic connector on the end with a slotted hole (shown on Figure 6). 1. Lift the locking nut and engage the flatted end of the encoder shaft into the slotted hole.
  • Page 19: Mounting The Wdc

    Product Manual e-Suite Tap 5.6 Mounting the WDC WARNING! The valve controller & WDC electronic control unit are electrical items and should be sited away from possible sources of water leaks. 1. Mount the WDC controller to the wall using the four fixing holes provided in the controller.
  • Page 20: Setting Stops

    5.7 Setting stops After installing the e-Suite tap the encoder must be set to register the stop position of the tap. This is done as follows: - 1. The WDC power must be on and all cables connected correctly.
  • Page 21: Commissioning For Use

    Product Manual e-Suite Tap 5.8 Commissioning for Use 1. Ensure the water supply is turned on. 2. Switch on the WDC controller at the power supply. Wait until WDC unit is fully booted and showing “READY” before proceeding. 3. Turn the tap on (anti clockwise).
  • Page 22: User And Maintenance Instructions

    If you need any further information or advice, please contact Wallgate customer services. Wallgate offers a comprehensive service package, details of which can be obtained from our customer service department.
  • Page 23: Maintenance

    Product Manual e-Suite Tap 6.2 Maintenance WARNING! The e-Suite Tap is not of conventional design and does not contain any serviceable items. The e-Suite Tap must not be disassembled by non Wallgate personnel. Contact Wallgate for all service requirements. The pillar tap is chrome plated and can be cleaned using warm soapy water, white vinegar and a soft cloth.
  • Page 24 Wallgate Ltd. Crow Lane, Wilton, Salisbury, Wiltshire, SP2 0HB, England tel: +44 (0) 1722 744594 fax: +44 (0) 1722 742096 email: service@wallgate.com web: www.wallgate.com Revision 3...

Table of Contents