Arctic Air AGF24Z Installation, Operation & Maintenance Manual

Arctic Air AGF24Z Installation, Operation & Maintenance Manual

Glass froster

Advertisement

INSTALLATION,
OPERATION &
MAINTENANCE
MANUAL
Glass Froster
IMPORTANT
Please read this manual completely
before attempting to install or operate this equipment.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGF24Z and is the answer not in the manual?

Questions and answers

Summary of Contents for Arctic Air AGF24Z

  • Page 1 INSTALLATION, OPERATION & MAINTENANCE MANUAL Glass Froster IMPORTANT Please read this manual completely before attempting to install or operate this equipment.
  • Page 2 Service and Installation Manual COMMECIAL REFRIGERATOR SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. Our product instructions will be uploaded on our company official website. This is the Safety Alert Symbol.
  • Page 3 Service and Installation Manual he key for appliance electric box should be safe kept by qualified persons in order to avoid a hazard ARNING: Keep ventilation openings, in the appliance enclosure or in the built-in structure, clear of obstruction. ARNING: Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
  • Page 4: Serial Number Information

    Service and Installation Manual CONTENTS RECEIVING & INSPECTING EQUIPMENTGGGGGGGGGGGGGGG..GGGGGGG4 SPECIFICATIONSGGGGGGGGGGGGGGGGGGGG.GGGGGGGGG.GGG5 INSTALLATIONGGGGGGGGGGGGGGGGGGGGGGGGGGGG.GGGG..G.6 OPERATIONGGG..GGGGGGGGGGGGGGGGGGGGGGGGGG..GGGGG7 MAINTENANCEGGGGGGGGGGGGGGGGGGGGGGGGGGG.GGGGGG.9 WIRING DIAGRAMGGGGGGGGGGGGGGGGGGGGGGGGGGGGGGG11 All rights reserved. Reproduction without written permission is prohibited. SERIAL NUMBER INFORMATION The serial number of all self-contained refrigerators and freezers is located inside the unit on the left hand side near the top on the wall.
  • Page 5: Specification

    Service and Installation Manual SPECIFICATION STORAGE SHELF CAPACITY CAPACITY CHARGE NEMA MODEL# V/Hz/Ph AMPS Cu-ft PLUG Sq-ft AGF24Z 115/60/1 2.67 3.53 5-15P AGF36Z 115/60/1 4.50 4.06 5-15P...
  • Page 6: Installation

    Service and Installation Manual INSTALLATION Utility requirements and Electrical Connections Electrical: 115 Volt AC, 1 Phase, 60 Hz, A separate 15 Amp circuit is recommended. A 9-foot grounded cord is included. All Glass Frosters models are shipped in one carton. These steps should be followed 1.
  • Page 7: Operation

    Service and Installation Manual OPERATION Do not throw items into the storage area. Failure to heed these recommendations could result in damage to the interior of the cabinet. Refrigerated cabinets Temperature range for the glass froster for all food prep units, -4 to 5 °F for glass froster.. Continuous opening and closing of the door will prevent the unit’s ability to maintain optimum refrigeration temperature.
  • Page 8 Service and Installation Manual 1.1 Function of LEDS 2. MAIN FUNCTIONS 2.1 HOW TO SEE THE SETPOINT 1. Push and immediately release the SET key: the display will show the set point value. 2. Push and immediately release the SET key or wait for 5 seconds to display the sensor value again.
  • Page 9 Service and Installation Manual MAINTENANCE The power switch must be turned OFF and the unit disconnected from the power source whenever performing service, maintenance functions or cleaning the refrigerated area. Refrigerators and Freezers The interior and exterior can be cleaned using soap and warm water. If this isn't sufficient, try ammonia and water or a nonabrasive liquid cleaner.
  • Page 10 Service and Installation Manual MAINTENANCE Cleaning solutions need to be alkaline based or non-chloride based. Any cleaner containing chlorides will damage the protective film of the stainless steel. Chlorides are commonly found in hard water, salts, and household and industrial cleaners. If cleaners containing chlorides are used, be sure to rinse and dry thoroughly.
  • Page 11: Wiring Diagram

    Service and Installation Manual WIRING DIAGRAM MODEL: AGF24Z/AGF36Z PLUG THERMAL OVERLOAD CUT-OFF PROTECTOR CONDENSEN COMPRESSOR POWER THERMOSTAT DISPLAY EVAP CURRENT STARTING RELAY CAPACITOR ROOM EVAP SENSOR...
  • Page 12 Service and Installation Manual WIRING DIAGRAM MODEL: AGF24Z/AGF36Z...
  • Page 13 Additional three-year compressor warranty* In addition to the two (2) year warranty stated above, Arctic Air warrants its compressor units to be free from defects in both material and workmanship under normal and proper use and maintenance service for a period of three (3) additional years from the date of original installation but not to exceed five (5) years and three (3) months after shipment from Arctic Air.
  • Page 14 Broich Enterprises, Inc. / Arctic Air 7550 Market Place Drive Eden Prairie, MN 55344 Phone: 952-941-2270 Fax: 952-941-3066 Website: www.arcticairco.com...