DTG
GATE SAFETY EDGE
TRANSMITTER
Installation
Instructions
(800) 421-1587 • www.linearcorp.com
TYPICAL
INSTALLATION
Remove Cover. Loosen the four screws on transmitter top and
STEP 1
remove cover.
REMOVE
COVER
Mount Safety Edge. Mount safety edge according to manufacturer's
STEP 3
instructions included with the product.
INSTALL
SAFETY EDGE
INSTR,INSTL,DTG
Linear P/N: 211906 Rev-D
Material: 20 Lb. Mead Bond
Size 8.500" x 11.000"
Ink: Black
Side 1 of 2
Scale: 1-1
DTG
TRANSMITTER
SAFETY EDGE
SENSOR
LOOSEN
SCREWS
DESCRIPTION
The DTG is part of Linear's Delta-3 product line and is compatible with all Delta-3
products. In a typical installation, the DTG is mounted on a motorized gate, door
or barrier arm and wired to a standard exterior safety edge sensor which
presents a closed circuit across the connecting wires when an object is hit during
the closing of a gate. To insure full compatibility with all gate edge safety
features, Linear recommends Miller gate edge sensors. If the edge sensor is
pressed for a minimum of 1/8 second, the DTG transmits a message to the
receiver to reverse the movement of the gate.
The DTG circuit board has been coated to prevent moisture damage and is
mounted inside a weather resistant fiberglass box. The mounting box attaches
to the gate through sealed interior mounting screws.
GATE
OPERATOR
Locate Parts. Refer to diagram below for transmitter parts location
STEP 2
and details.
CODE SWITCH
KEYS
9 VOLT
ALKALINE OR
LITHIUM BATTERY
Mount DTG. Choose a location as high as possible on gate in a
STEP 4
secure position. Use the template attached to mark the location for the
transmitter. You may have to attach a metal or wood plate to mount transmitter.
Use a 3/32" bit and drill holes. Attach DTG to gate using the four #6 self-tapping
drill point screws.
WELD PLATE
1.77"
3.88"
ATTACH DTG
TO PLATE
ANTENNA
TEST
INDICATOR
TEST
SWITCH
SAFETY EDGE
INPUT TERMINALS
TO GATE

Advertisement

loading

Summary of Contents for Linear Delta-3 DTG

  • Page 1 DESCRIPTION The DTG is part of Linear’s Delta-3 product line and is compatible with all Delta-3 GATE SAFETY EDGE products. In a typical installation, the DTG is mounted on a motorized gate, door or barrier arm and wired to a standard exterior safety edge sensor which...
  • Page 2 (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. WARNING: equipment. Copyright © 2019 Nortek Security & Control LLC 211906 Rev-D INSTR,INSTL,DTG Linear P/N: 211906 Rev-D Material: 20 Lb. Mead Bond Size 8.500" x 11.000" Ink: Black Side 2 of 2 Scale: 1-1...