CAR-connect VAS 6558A/29 Operating Manual

CAR-connect VAS 6558A/29 Operating Manual

High-voltage test adapter

Advertisement

Quick Links

Operating manual
H i g h - v o lt a g e t e s t a da p t e r V A S 6 5 5 8 A / 2 9
12.VW.2210.1369_BA_V02_EN
VAS 6558A/29
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VAS 6558A/29 and is the answer not in the manual?

Questions and answers

Summary of Contents for CAR-connect VAS 6558A/29

  • Page 1 Operating manual H i g h - v o lt a g e t e s t a da p t e r V A S 6 5 5 8 A / 2 9 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 2: Legal Notice

    Copyright All rights reserved. All text, images and graphics are subject to copyright and other intellectual property laws. Copyright 2020 CAR-connect GmbH. Image sources Symbols for warnings, prohibitions, mandatory actions and standards are taken from publicly accessible sources, such as the Internet. CAD product images and product photos are provided by the manufacturer.
  • Page 3: Table Of Contents

    Requirements for the target group Duties of the operator PRODUCT DESCRIPTION Scope of delivery Design Symbols and connections Wiring diagram Technical data OPERATION Startup Detaching the plug connections Cleaning Storage and transportation Disposal Maintenance HELP Warranty Customer service 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 4: Introduction

    Our portfolio also includes measurement and diagnostic technology for the entire vehicle and battery analysis equipment. With extensive experience in software and hardware development, CAR-connect is your dependable partner at every production stage, from prototyping to series production.
  • Page 5: Safety

    This operating manual is only valid for the following product: Item number 22101369 Designation Hochvolt-Prüfadapter VAS 6558A/29 Warning levels This chapter provides information about the warning levels used in this operating manual. DANGER Failure to observe the safety instructions WILL result in death or serious injury!
  • Page 6: Important Safety Instructions

    Defective and damaged products cannot guarantee protection against electrical voltage! • Do not let the product come into contact with chemicals! • Replace a defective or damaged product immediately! • Never attempt to repair or tamper with the product! 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 7: Intended Use

    The operator is also responsible for ensuring that the following conditions are met: • The measurement adapter is always in perfect working order. • The regular inspection intervals for the measurement adapter are observed and recorded. 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 8: Product Description

    Immediately check the condition of the product and the completeness of the delivery. If anything is missing or defective, please contact the manufacturer immediately. High-voltage test adapter USB stick with operating manual Design Product design: Socket Test sockets (see wiring diagram) 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 9: Symbols And Connections

    General warning symbols Electrical hazard! Read the operating manual! Serial number of the product Manufacturer part number Protection class II Disposal instruction Mark of conformity Vehicle manufacturer’s certification mark cMETus certification mark Measurement category according to IEC 61010-1 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 10 The product has the following connection areas: • • Connection area TP1 has the following sockets: Connector Function Functional ground socket Positive socket Negative socket Pilot sockets Connection area TP2 has the following sockets: Connector Function Pilot sockets 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 11: Wiring Diagram

    EN | 4BProduct description Wiring diagram 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 12: Technical Data

    Max. 2000 m No limitation Humidity Max. 80 % up to 31° C, Max. 85 % decreasing linearly to 50 % at 40° C Condensation not permitted. Maximum permissible relative humidity: 60 % in environments with corrosive gas/air. 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 13: Operation

    Danger of fatal electric shock! The electrical voltage in high-voltage systems is lethal and can cause death by electric shock! • Use the product only for the applications intended by the vehicle manufacturer! Observe the safety instructions. 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 14 Connect the plug to the disconnected socket of the connection you want to test. Lock the connection. Connect the high-voltage measurement module to the high-voltage test adapter according to the guided fault finding.  You can now perform measurements in accordance with the guided fault finding. 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 15: Detaching The Plug Connections

    The plug connections have an automatic locking mechanism. To detach a plug connection: Pull out the catch (red). Push in and hold the tongue (orange). Pull the plug connection apart.  The plug connection is now detached. 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 16: Cleaning

    Observe the safety instructions! National and local requirements for regular testing must be observed! Test the product for proper function at intervals of no more than 24 months. Contact the manufacturer to have a professional function test performed. 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...
  • Page 17: Help

    Help Warranty CAR-connect GmbH grants a warranty period of 24 months from the date of purchase. The warranty is valid for demonstrable defects in functional material and workmanship. Further information on the warranty conditions can be found in the terms and conditions on the manufacturer’s website.
  • Page 18 Volkswagen Aktiengesellschaft K-GVO-LW Group After Sales – Group Service Literature and Systems Repair Shop Equipment PO box 011/4915 38442 Wolfsburg, Germany For internal use only Subject to technical changes Edition 10 / 2020 12.VW.2210.1369_BA_V02_EN VAS 6558A/29...

Table of Contents