HearthSense BLUE FLAME BF10M-B Owner's Operation And Installation Manual

HearthSense BLUE FLAME BF10M-B Owner's Operation And Installation Manual

Vent-free gas wall heater
Table of Contents

Advertisement

Available languages

Available languages

VENT - FREE GAS WALL
HEATER
OWNER'S OPERATION AND
INSTALLATION MANUAL
BLUE FLAME MODEL
BF10M - B
WARNING: If the information in this manual is not
followed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable va-
pors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
WARNING: This appliance is equipped for natural and
propane gas. Field conversion is not permitted other than
between natural or propane gases.
Before returning to your retailer, call our customer service department at
Questions, problems, missing parts?
1-866-573-0674, 8:00 am - 4:30 pm CST, Monday through Friday

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLUE FLAME BF10M-B and is the answer not in the manual?

Questions and answers

Summary of Contents for HearthSense BLUE FLAME BF10M-B

  • Page 1 VENT - FREE GAS WALL HEATER OWNER’S OPERATION AND INSTALLATION MANUAL BLUE FLAME MODEL BF10M - B WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. —...
  • Page 2: Table Of Contents

    * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer. PATENT INFORMATION This product may be covered by one or more of the following United States patents: 9,829,195 9,423,123 9,441,833 9,518,732 9,752,779 9,416,977 8,764,436 8,568,136 8,516,878 8,297,968 8,281,781 8,235,708 7,967,006 7,967,007 7,730,765 7,677,236 7,607,426 7,434,447 HearthSense 200549-01A...
  • Page 3: Safety

    Allow ence of alcohol and those at high altitudes. surfaces to cool before touching. NATURAL AND PROPANE GAS: Natural and propane gas are odorless. An odor-making HearthSense 200549-01A...
  • Page 4: Qualified Installing Agency

    HearthSense 200549-01A...
  • Page 5: Specifications

    T-handle type. The State of Massachusetts requires that a flexible This heater is designed for vent-free op- appliance connector cannot exceed three eration. State and local codes in some areas feet in length. prohibit the use of vent-free heaters. HearthSense 200549-01A...
  • Page 6: Preparing For Installation

    In most applications, 3. Do not use an unvented room heater as the water vapor enhances the low humidity the primary heat source. atmosphere experienced during cold weather. HearthSense 200549-01A...
  • Page 7: Air For Combustion And Ventilation

    Exhaust fans, fireplaces, clothes dryers and fuel burning appliances draw air from the house to operate. You must provide adequate fresh air for these appliances. This will insure proper venting of vented fuel-burning appliances. HearthSense 200549-01A...
  • Page 8 Outlet Room, Door into Attic Option 1 Adjoining Room, Option 3 Outlet To Attic 12" Crawl Space Inlet Ventilated Inlet Air Crawl Space Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building HearthSense 200549-01A...
  • Page 9: Installation

    • in windy or drafty areas From Sides of Right Heater Side Left Side 2" Minimum to Top Surface of Carpeting, Tile or Other Combustible Material FLOOR Figure 4 - Mounting Clearances as Viewed From Front of Heater HearthSense 200549-01A...
  • Page 10 (concrete or masonry). ing bracket to attach bracket to wall. Attach Decide which method better suits your needs. mounting bracket to a wall only in one of two Either method will provide a secure hold for ways: the mounting bracket. HearthSense 200549-01A...
  • Page 11 1. Drill holes at marked locations using 9/64" drill bit. Figure 8 - Popping Open Anchor Wings 2. Place mounting bracket onto wall. Line For Thin Walls up last hole on each end of bracket with holes drilled in wall. HearthSense 200549-01A...
  • Page 12 8. Tighten both screws until heater is firmly secured to wall. Do not over tighten. Note: Do not replace front panel at this time. Replace front panel after making gas connec- tions and checking for leaks. Screw Figure 12 - Securing Heater to Floor HearthSense 200549-01A...
  • Page 13 Install Gas Fitting Here gas type. Blue is for propane (LP Fitting gas) and yellow is for natural gas. supplied by installer, may vary. INLET GAS PRESSURE MAX 1/2 PSIG (3.5 KPA) Gas Connection Figure 13 - Bottom of Heater HearthSense 200549-01A...
  • Page 14 If you are using natural gas use a wrench to complete tightening of the fitting. Install additional fitting to connect and the pilot will not light, see to the house supply. Troubleshooting, page 22. HearthSense 200549-01A...
  • Page 15 (see Figure 15, page 16). IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance. HearthSense 200549-01A...
  • Page 16 5. Correct all leaks at once. 3. Pressurize supply piping system by either 6. Reconnect heater and equipment shutoff opening propane supply tank valve for valve to gas supply. Check reconnected propane gas or opening main gas valve fittings for leaks. HearthSense 200549-01A...
  • Page 17 3. Make sure control knob of heater is in the OFF position. 8. Replace front panel. 4. Check all joints from equipment shutoff valve to control valve (see Figure 18 or 19). Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. HearthSense 200549-01A...
  • Page 18: Operation

    Troubleshooting, pages 22 though 25. Also contact a quali- fied service technician or gas supplier for repairs. Until repairs are made, light pilot with match. Figure 20 - Control Knob in the OFF Position HearthSense 200549-01A...
  • Page 19 2. Follow steps 2 through 5 under Lighting release control knob. Follow step 8 under Instructions, page 18. Lighting Instructions, page 18. 3. With control knob pressed in, strike match. 5. Replace front panel. Hold match to pilot until pilot lights. HearthSense 200549-01A...
  • Page 20: Inspecting Burners

    If burner flame pattern is incorrect as shown in Figure 25: Yellow • turn heater off (see To Turn Off Gas to Ap- Tipping pliance, page 19) • see Troubleshooting pages 22 through 25. Opening Height Figure 25 - Incorrect Burner Flame Pattern HearthSense 200549-01A...
  • Page 21: Care And Maintenance

    Figure 26 - Pilot Inlet Air Hole CABINET Exterior Air Passageways • Use a soft cloth dampened with a mild soap Use a vacuum cleaner or pressurized air to and water mixture. clean. • Wipe the cabinet to remove dust. HearthSense 200549-01A...
  • Page 22: Troubleshooting

    Use a small flat bladed screw driver to turn the set screw counterclockwise 2 turns. This will bypass the pressure switch Figure 27 - Gas Regulator Pressure function. Switch (Inside Bottom of Heater Cabinet) HearthSense 200549-01A...
  • Page 23 Maintenance, page 21) or replace ODS/pilot assembly. 6. Incorrect inlet gas pressure 6. Check inlet gas pressure or or inlet regulator setting is replace inlet gas regulator. damaged. 7. Depleted gas supply (pro- 7. Contact local propane gas pane). company. HearthSense 200549-01A...
  • Page 24 1. Take apart gas tubing and bustion. control valve and burner. remove foreign matter. 2. Gas leak. (See Warning 2. Locate and correct all leaks Statement at top of page 22). (see Checking Gas Connec- tions, page 16). HearthSense 200549-01A...
  • Page 25: Technical Service

    Ventilation require- ments, page 7. TECHNICAL SERVICE You may have further questions about installation, operation, or troubleshooting. If so, contact ProCom Heating, Inc. at 1-866-573-0674. When calling, please have your model and serial numbers of your heater ready. HearthSense 200549-01A...
  • Page 26: Parts

    PARTS MODEL BF10M - B HearthSense 200549-01A...
  • Page 27 Replacement Parts on page 28 of this manual. ITEM PART # DESCRIPTION 161132-01 Mounting Bracket 161133-01 Piezo Ignitor 161391-01 Control Knob 160960-01 Cap with Seal 161528-01 Screen PF0910B-RW Base Feet PART AVAILABLE - NOT SHOWN 161607-01 Hardware Package HearthSense 200549-01A...
  • Page 28: Replacement Parts

    • burners will have delayed ignition • heater will not produce specified heat • propane gas supply might be low (propane units only) You may feel your gas pressure is too low. If so, contact your local gas supplier. HearthSense 200549-01A...
  • Page 29 NOTES ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ HearthSense 200549-01A...
  • Page 30: Warranty

    WARRANTY KEEP THIS WARRANTY Model _______________________________ Serial No. ____________________________ Date Purchased _______________________ Keep receipt for warranty verification. REGISTER YOUR PRODUCT AT WWW.USAPROCOM.COM IMPORTANT: We urge you to register your product within 10 days of date of installation, complete with entire serial number which can be found on the rating plate. Please fill out the warranty infor- mation above for your personal records.
  • Page 31 CALENTADOR DE GAS DE PARED SIN VENTILAS MANUAL DE FUNCIONAMIENTO Y INSTALACIÓN DEL PROPIETARIO MODELO LLAMA AZUL BF10M - B ADVERTENCIA: si la información contenida en este manual no se sigue al pie de la letra, se puede producir un incendio o una explosión que podría ocasionar daños a la propiedad, lesiones personales o la pérdida de la vida.
  • Page 32 Este dispositivo es sólo para su uso con propano o gas natural. No se permite la conversión de campo por cualquier otro medio, incluido el uso de un kit. * Mercado de posventa: venta completada por parte del fabricante, sin fines de reventa HearthSense 200549-01A...
  • Page 33: Seguridad

    Intoxicación con monóxido de carbono: los síntomas iniciales de la intoxicación con monóxido de carbono son semejantes a los HearthSense 200549-01A...
  • Page 34 3. Este calentador necesita ventilación con tanques de gas propano de menos de aire fresco del exterior para funcionar 45 kg (100 libras) de capacidad. correctamente. Este calentador tiene un HearthSense 200549-01A...
  • Page 35: Especificaciones

    HearthSense 200549-01A...
  • Page 36: Características Del Producto

    INFORMACIÓN DE PATENTES Este producto puede estar cubierto por una o más de las siguientes patentes de Estados Unidos: 9,829,195 9,423,123 9,441,833 9,518,732 9,752,779 9,416,977 8,764,436 8,568,136 8,516,878 8,297,968 8,281,781 8,235,708 7,967,006 7,967,007 7,730,765 7,677,236 7,607,426 7,434,447 HearthSense 200549-01A...
  • Page 37: Preparación Para La Instalación

    En la mayoría de las aplicaciones, el vapor calefacción. de agua contribuye a la baja humedad de la atmósfera que se experimenta en climas fríos. HearthSense 200549-01A...
  • Page 38: Aire Para Combustión Y Ventilación

    Los extractores de aire, chimeneas, se- cadoras de ropa y aparatos que queman combustible toman aire de la casa durante su funcionamiento. Usted debe proporcionar aire fresco adecuado para estos aparatos. Esto asegurará una adecuada ventilación de los aparatos que queman combustible ventilados. HearthSense 200549-01A...
  • Page 39 Outlet opción 1 adyacente, To Attic opción 3 Crawl Space 30.5 cm Inlet (12") Ventilated Inlet Air Crawl Space Figura 3 - Aire del exterior para ventilación Figura 2 - Aire del interior de la construcción para ventilación HearthSense 200549-01A...
  • Page 40: Instalación

    Mida desde el punto • en áreas de mucho tráfico más alejado del calentador. • en áreas con mucho viento o con corrientes fuertes de aire HearthSense 200549-01A...
  • Page 41 DESMONTAJE DEL PANEL ANTERIOR 1. Retire los 4 tornillos que fijan el panel frontal. Tornillo Panel anterior Figura 5 - Desmontaje del panel anterior HearthSense 200549-01A...
  • Page 42 Alinee el último orificio de cada tancias mínimas mayores con extremo del soporte con los orificios que perforó en la pared. 3. Inserte los tornillos de montaje en el so- porte y en las vigas de pared. HearthSense 200549-01A...
  • Page 43 6. Inserte los tornillos de montaje en el so- porte y en los anclajes de pared. Figura 7 - Cómo doblar el anclaje Figura 8 - Cómo abrir las alas del anclaje para paredes delgadas HearthSense 200549-01A...
  • Page 44 Figura 11 - Colocación de patas de la base de calentador Front View Vista frontal Front View Tornillo Figura 12 - Fijación del calentador de piso Pared Calentador Separador Vista lateral Side View Side View Figura 10 - Instalación de los tornillos de montaje inferiores HearthSense 200549-01A...
  • Page 45 (gas LP) y el amarillo es para el gas natural. Racor suministrados por el instalador, puede variar. INLET GAS PRESSURE MAX 1/2 PSIG (3.5 KPA) Conexión de gas Figura 13 - Parte inferior del calentador HearthSense 200549-01A...
  • Page 46 , con- apretado sido parte en el regulador con sulte Solución de Problemas, en una llave para completar endurecimiento la página 56. del accesorio. Instale accesorio adicional para conectar al suministro de la casa. HearthSense 200549-01A...
  • Page 47 1/8" es una alternativa aceptable como conexión línea de gas es superior, podría da- para el medidor de prueba. La válvula opcional ñarse el regulador del calentador. de cierre de equipo con diseño certificado por la CSA la puede adquirir con su distribuidor. HearthSense 200549-01A...
  • Page 48 Tapón (3") Figura 16 - Regulador externo Figura 15 - Conexión de gas con la ventila apuntando hacia * Adquiera la válvula opcional de cierre de equipo abajo (sólo propano o gas) certificada con diseño CSA del distribuidor. HearthSense 200549-01A...
  • Page 49 4. Repare todas las fugas inmediatamente. Medidor de gas Abierta Válvula de cierre Válvula de del equipo cierre del equipo Cerrada Figura 17 - Válvula de cierre del equipo Figura 19 - Suministro de gas natural HearthSense 200549-01A...
  • Page 50: Funcionamiento

    • No intente encender ningún aparato. del sistema de control y los controles • No toque ningún interruptor eléctrico; de gas que hayan estado sumergidos no use ningún teléfono en el edificio. en agua. HearthSense 200549-01A...
  • Page 51 Nota: Las dos altas y bajas son posiciones de bloqueo. Debe pulsar en el botón de control antes de volver a partir de estas Figura 20 - Perilla de control en la posiciones. posición OFF (apagado) HearthSense 200549-01A...
  • Page 52 3. Con la perilla de control presionada, Realice el paso 8 de las Instrucciones de encienda un fósforo. Sostenga el fósforo encendido, página 51. en el piloto hasta que éste se encienda. 5. Vuelva a colocar el panel anterior. HearthSense 200549-01A...
  • Page 53: Inspección Del Calentador

    1/2 de la 1/2 Glass página 52). altura del Height vidrio • consulte Solución de problemas, en la página 56 a 60. Figura 25 - Patrón incorrecto de la llama del quemador HearthSense 200549-01A...
  • Page 54: Cuidado Y Mantenimiento

    6. Vuelva a colocar el panel frontal mediante lata, siga las instrucciones que aparecen en tornillos retirados en el paso 2. la lata. Si no sigue las instrucciones escritas en la lata, puede dañar el ensamble del piloto. HearthSense 200549-01A...
  • Page 55 Figura 26 - Orificio de entrada de aire al piloto GABINETE Conductos de aire Utilice una aspiradora o aire comprimido para limpiarlos. Exterior • Utilice un paño humedecido con una mezcla de agua y jabón suave. • Frote el gabinete para quitar el polvo. HearthSense 200549-01A...
  • Page 56: Solución De Problemas

    Utilice un pequeño destornillador de punta plana para girar el tornillo de ajuste en sentido antihorario 2 vueltas. Esto pasará por alto la función de interruptor de presión. HearthSense 200549-01A...
  • Page 57 7. Se agotó el suministro de 7. Comuníquese con la compa- gas (gas propano única- ñía local de gas propano. mente). HearthSense 200549-01A...
  • Page 58 Cuidado y mantenimiento, en la combustión. la página 54). 2. El quemador está dañado. 2. Contactar servicio al cliente. 3. El regulador de gas está 3. Contactar servicio al cliente. defectuoso. HearthSense 200549-01A...
  • Page 59 3 Respete las distancias míni- lentador están bloqueados. mas de instalación (consulte Figura 4, pagina 41) 4. El orificio del quemador 4 Limpie el quemador (consulte está sucio o parcialmente Cuidado y mantenimiento, en obstruido. la página 54). HearthSense 200549-01A...
  • Page 60: Consejos Para Servicio

    • El quemador tendrá un retraso durante el encendido. • El calentador no producirá el calor especificado. • El suministro de gas propano puede ser bajo. Posiblemente piense que la presión del gas es muy baja. Si es así, comuníquese con el proveedor local de gas. HearthSense 200549-01A...
  • Page 61: Piezas De Repuesto

    ProCom Heating, Inc. al 1-866-573-0674 para obtener información. KIT DE CONEXIÓN DE APARATO DE GAS UNIVERSAL Modelo HSVFIK: para todos los modelos de calentadores de gas. Incluye accesorios gene- rales necesarios para conectar el calentador a la línea de gas. HearthSense 200549-01A...
  • Page 62 PIEZAS MODELO BF10M - B HearthSense 200549-01A...
  • Page 63 Art. Parte # Descripción Cant. 161132-01 Abrazadera de montaje 161133-01 Encendedor piezo eléctrico 161391-01 Perilla de control 160960-01 Casquillo con el sello 161528-01 Rejilla PF0910B-RW Patas de la Base PIEZAS DISPONIBLES - NO SE MUESTRAN 161607-01 Hardware paquete HearthSense 200549-01A...
  • Page 64: Garantía

    GARANTÍA GUARDE ESTA GARANTÍA Modelo __________________________________ Número de serie __________________________ Fecha de compra _________________________ Conserve su recibo para la verificación de la garantía. REGISTRE SU PRODUCTO EN WWW.USAPROCOM.COM IMPORTANTE: Le pedimos que registre su producto dentro de los 10 días de la fecha de instalación, lleve a cabo con el número de serie completa que se puede encontrar en la placa de características.