Submersible sewage and effluent pumps

Advertisement

Connect or wire pump to an individual branch circuit with no
other outlets or equipment in the circuit. Size fuses or circuit
breakers according to chart below.
Risk of electrical shock and fire. Be sure that
power supply information (Voltage/ Hertz/Phase) on pump
motor nameplate matches incoming power supply exactly.
Install pump according to all electrical codes that apply.
Voltage/
Model
HP
Phase
P-SU-13T
1/3
115/1
P-SE-13T
P-SE-41T
4/10
115/1
P-SE-12T
1/2
115/1
P-SS-41T
4/10
115/1
P-SS-12T
1/2
115/1
P-SS-34T
3/4
115/1
P-SE-10T
1
230/1
Operation
NOTICE: Do not allow pump to run dry. It will void the war-
ranty and may damage the pump.
An automatic overload protector in the motor will protect
motor from burning out due to overheating/overloading. When
motor cools down, overload protector will automatically reset
and start motor.
If overload trips frequently, check for cause. It could be a
stuck impeller, wrong/low voltage, or electrical failure in
motor. If an electrical failure in the motor is suspected, have
it serviced by a competent repairman.
TROUBLES-REMEDIES
Sudden Starts. If power is on to pump when thermal overload resets, pump may start
without warning. If you are working on pump, you may get an electrical shock or impeller may catch
fingers or tools. Disconnect power before servicing pump.
A. Pump fails to operate:
B. Pump fails to empty sump:
C. Pump will not shut off:
Effluent pumps are warranted against defects in material and workmanship for a period of 30 months from the date of original installation, not
to exceed 3 years from the date of manufacture, whichever occurs first. In no event shall Quanics be liable for any consequential damages or
any labor, material, freight or expense required to replace, correct or reinstall the product.Quanics' liability is limited to repair or replacement of
the part. All warranties are void if the product has been improperly modified, applied or installed, subjected to misuse or abuse. Except as stat-
ed herein, there are no warranties express or implied, including the warranty of merchantability or warranty of fitness for a specific purpose.
Individual
Max Load
Branch Circuit
Amps
Required (Amps)
9.8
15
9.7
15
13.0
15
12.5
15
9.0
15
12.0
15
6.6
15
1. Check to be sure that power cord is securely plugged into outlet or securely wired into
controller or switch box. Disconnect power to outlet before handling pump or motor.
2. Check to be sure you have electrical power.
3. Check that liquid fluid level is high enough to activate switch or controller.
4. Check to be sure that 3/16" vent hole in discharge pipe is not plugged.
5. Check for blockage in pump inlet, impeller, check valve or discharge pipe.
6. Thermal overload may have tripped. Test start pump; if it starts and then stops
immediately, disconnect from power source for 30 minutes to allow motor to cool,
then reconnect to power source. Check for cause of overheating/overloading.
1. Be sure all valves in discharge pipe are fully open.
2. Clean out discharge pipe and check valve.
3. Check for blockage in pump inlet or impeller.
4. Pump not sized properly. A higher capacity pump may be required.
1. Check switch or controller automatic floats for proper operation and location.
See installation instructions for switch/controller.
2. If pump is completely inoperative or continues to malfunction, consult your
local serviceman.
LIMITED WARRANTY
Quanics
TM
• P.O. Box 1520 • Crestwood, KY 40014 • www.quanics.net
Pump is permanently lubricated. No oiling or greasing is
required.
SERVICE –
General
Hazardous voltage. Can shock, burn, or
cause death. Before removing pump from basin, always dis-
connect electrical power to pump and control switch.
After removing basin cover and necessary discharge piping,
lift pump out of basin.
Risk of cord damage and electrical shock.
Can burn or kill. Do not lift pump by power cord.
1. Attempting to lift or support pump by power cord can dam-
age cord and cord connections.
2. Cord may pull apart, exposing bare wires with possibility of
fire or electrical shock.
3. Lifting or supporting pump by power cord will void warranty.
4. Use lifting ring or handle on top of pump for all lifting/lower-
ing of pump. Disconnect power to pump before doing any
work on pump or attempting to remove pump from sump