Download Print this page

Haier YR-HD Operation Manual page 2

Hide thumbs Also See for YR-HD:

Advertisement

Operation
Remote
Mode
Controller
Under the mode of auto operation, air conditioner
will automatically select Cool /Heat / Fan operation
AUTO
according to room temperature. When FAN is set to
AUTO the air conditioner automatically adjusts the
fan speed according to room temperature.
COOL
In DRY mode , when room temperature becomes
lower than temp.setting+2°C, unit will run
DRY
intermittently at LOW speed regardless of FAN
setting (only valid for part of models).
In HEAT mode, warm air will blow out after a short
period of the time due to cold-draft prevention
HEAT
function. When FAN is set to AUTO, the air
conditioner automatically adjusts the fan speed
according to room temperature.
In FAN operation mode , the unit will not operate in
COOL or HEAT mode but only in FAN mode, AUTO
FAN
is not available in FAN mode. And temp. setting
is disabled. In FAN mode, sleep operation is not
available.
Sleep Operation
Press
button to enter additional options, when cycle display
to
,
will flash. And then press
Operation Mode
1. In COOL, DRY mode
1 hours after SLEEP mode starts, temp.will become 1°C higher
than temp.setting.After another 1 hours, temp.rises by 1°C futher.
The unit will run for further 6 hours then stops Temp. is higher than
temp.setting so that room temperature won't be too low for your
sleep.
2.In HEAT mode
1 hours after SLEEP mode starts,temp will become 2°C lower than
temp. setting. After another 1 hours, temp decrease by 2°C futher.
After more another 3 hours, temp. rises by 1°C futher.The unit will
run for further 3 hours then stops.Temp.is lower than temp. setting
so that room temperature won't be too high for your sleep.
Temp. setting
Unit stop
1 hr
Decreases 2°C
1 hr
Decreases 2°C
3 hrs
Rises 1°C
3 hrs
SLEEP operation starts
SLEEP operation stops
In HEAT mode
3.In AUTO mode
The unit operaters in corresponding sleep mode adapted to the
automatically selected operation mode.
4. In FAN mode
It has no SLEEP function.
Note: When TIMER function is set, the sleeping function can't be set up.
After the sleeping function is set up, if user resets TIMER function, the
sleeping function will be cancelled; the machine will be in the state of
timing on/ timing off.
POWER/QUIET Operation
1. POWER Operation
When you need rapid heating or cooling, you can use this function.
Press
button to enter additional options, when cycle display
to
,
will flash, and then press
function. When cancel the function, please enter additional options
again and to cancel power function.
2. QUIET Operation
You can use this function when silence is needed for rest or
reading. Press QUIET button, the remote controller will show
, and then achieve to the quiet function. Press again this QUIET
button , the quiet function will be cancelled.
Note
enter to sleep function.
SLEEP operation starts
SLEEP operation stops
Approx. 6hrs
Rises 1°C
1 hr
Rises 1°C
1 hr
Temp. setting
Unit stop
In COOL, DRY mode
, enter to power
Note: During POWER operation, in rapid HEAT or COOL mode, the room
will show inhomogeneous temperature distribution. Long period QUIET
operation will cause effect of not too cool or not too warm.
Air Flow Direction Adjustment
1.Status display of air flow
COOL/DRY:
HEAT:
Initial state
2. Left and right air flow adjustment
Initial state
Timer On/Off On-Off Operation
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every time the
button is pressed, display changes as follows: Remote controller:
Then select your desired TIMER mode (TIMER ON or TIMER OFF
or TIMER ON-OFF). "
3.Press
/
button to set time.
Press the button for each time, setting time in the first
12 hours increased by 0.5 hour every time, after 12
hours,increased by 1 hour every time.
Press the button for each time, setting time in the first
12 hours decreased by 0.5 hour every time, after 12
hours,decreased by 1 hour every time.
It can be adjusted within 24 hours.
4.Confirm timer setting
After adjust the time, press
or OFF button will not flash any more.
5.Cancel timer setting
Press the timer button by times until the time display eliminated.
Press
button to cancel timer setting.
Hints: After replacing batteries or a power failure happens, time setting
should be reset. According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be achieved.
Healthy airflow Operation
1.Press
to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
Press
button to enter additional options,Press this button
continuously, the louvers location will cycle between in the following
three locations, to choose the swing location what you needed,and
then press
button to confirm.
Healthy
Healthy
airflow
airflow
upwarder
downwarder
3.The cancel of the healthy airflow function
Press
button to enter additional options,Press this button
continuously, the louvers location will cycle between in the following
three locations again,and then press
Note:
1.After setting the healthy airflow function, the position grill is fixed.
2.In heating, it is better to select the
3.In cooling, it is better to select the
4.In cooling and dry, using the air conditioner for a long time under the
high air humidity, condensate water may occur at the grille .
"or "
"will flash.
button and confirm the time ON
Left and
Right
swing
button to cancel.
mode.
mode.

Advertisement

loading