Download Print this page

Advertisement

Available languages

Available languages

SPYLOS DUVAR TİPİ SPLİT KLİMA KULLANMA KLAVUZU
SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
Klimayı kullanmadan önce bu kullanım kılavuzunu okuyunuz.
Kullanım kılavuzunu saklayınız.
Bu cihaz R32 gaz ile doldurulmuştur
Please read this operation manual before using the air
conditioner. Keep this operation manual for future reference
This appliance is filled with R32.
0011510304
ESA1309A100
ESA1312A100
ESA1318A100
ESA1324A100

Advertisement

loading
Need help?

Need help?

Do you have a question about the ESA1309A100 and is the answer not in the manual?

Questions and answers

Summary of Contents for E.C.A. ESA1309A100

  • Page 1 SPYLOS DUVAR TİPİ SPLİT KLİMA KULLANMA KLAVUZU SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL ESA1309A100 ESA1312A100 ESA1318A100 ESA1324A100 Klimayı kullanmadan önce bu kullanım kılavuzunu okuyunuz. Kullanım kılavuzunu saklayınız. Bu cihaz R32 gaz ile doldurulmuştur Please read this operation manual before using the air conditioner.
  • Page 2 Read the precautions in this manual This appliance is filled with R32. carefully before operating the unit. Keep this manual where the user can easily nd it. WARNING: · Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
  • Page 3: Table Of Contents

    Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLATION MAINTENANCE CAUTIONS TROUBLE SHOOTING...
  • Page 4: Parts And Functions

    Parts and Functions Indoor Unit Remote controller 6. TIMER OFF display Inlet Air Purifying Filter (inside) TIMER ON display 7. TEMP display 8. Additional functions display Inlet grille Supplemented electrical Operation mode QUIET SLEEP HEALTH TURBO heating Remote controller Emergency 9.
  • Page 5: Operation

    Operation Base Operation Emergency operation and test operation Emergency Operation: Use this operation only when the remote controller is defective Turbo/Quiet Auto or lost, and with function of emergency running, air conditoner Remote controller Cool Heat can run automatically for a while. Temp+ When the emergency operation switch is pressed, the "...
  • Page 6 Operation Comfortable SLEEP 5. When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted.When TIMER function is set,the quiet sleeping function can't be set up.After the sleeping function is set up,if user resets TIMER function, the Press button , the remote controller will sleeping function will be cancelled;...
  • Page 7 Operation TURBO/QUIET Operation Timer On/Off On-Off Operation 1.After unit starts, select your desired operation mode. 2.Press button to change TIMER mode. Timer On Timer off Turbo/Quiet Auto Press button " 0.5 " will appear ,after 10 seconds Cool Heat Timer On the time display will be blank.
  • Page 8: Indoor Unit Installation

    Indoor Unit Installation Necessary Tools for Installation Power Source Torque wrench Driver Before inserting power into receptacle, check the voltage without (17mm,22mm,26mm) Nipper fail. Pipe cutter Hacksaw The power supply is the same as the corresponding nameplate. Flaring tool Hole core drill Install an exclusive branch circuit of the power.
  • Page 9 Drain hose Lid for left piping Lid for under piping pipe A=130mm C=110mm Fix with adhesive tape ESA1309A100 Indoor/outdoor electric cable and drain hose must be bound with efrigerant piping by protecting tape. A=120mm C=80mm [ Other direction piping ] 60mm Ø...
  • Page 10 Correct Incorrect When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall Lean Damage of flare Partial Too outside Crack hole, in which the pipe has already existed. 2.
  • Page 11: Maintenance

    Maintenance For Smart Use of The Air Conditioner Remote Controller Indoor Body Setting of proper room Do not block the air inlet temperature or outlet Proper wipe the air conditioner by using a temperature soft and dry cloth.For serious stains, use a neutral detergent diluted with Do not usewater,wipe the controller water.Wring the water out of the...
  • Page 12: Cautions

    Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING Check proper When abnormality such as burnt-small found, Use an exclusive immediately stop the operation button and installation of the power source...
  • Page 13: Trouble Shooting

    Trouble shooting Cautions Before asking for service, check the following grille of the air Do not obstruct or cover the ventilation first. conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. This appliance is not intended for use by persons (including children) Phenomenon Cause or check points with reduced physiced, sensory or mental capabilities or lack of...
  • Page 14 Üniteyi çal t rmadan önce bu k lavuzdaki uyar lar dikkatle Bu cihaz, R32 ile doldurulur. okuyun. Bu kullan m k lavuzu kullan c n n kolayca bulabilece i bir yerde saklanmal d r. UYARI: Buz çözme sürecini hızlandırmak için, üretici tarafından tavsiye edilenden başka, temizleme cihazlarını kullanmayın.
  • Page 15 Turbo/Quiet Auto Cool Heat Health Extra Function Timer On Confirm/Cancel Sleep Timer off Lock Light G örüntü Paneli 1-Uzaktan kumanda alıcısı Ortam sıcaklı ı gösterimi (Uzaktan kontrol sinyali alındı ında, ayar sıcaklı ını gösterir) Operasyon modu göstergesi (Kompresör açıldı ında yanar.) WIFI (Isteğe bağlı)
  • Page 16 Turbo/Quiet Auto Cool Heat Temp+ Swing Swing Temp- Health Extra Function Timer On Sleep Confirm/Cancel Timer Off Lock Reset Light COOL/DRY: HEAT: (Bu fonksiyon bu modelde aktif değildir. sadece Klima üzerinden el ile yapılmaktadır.)
  • Page 17 (Bu fonksiyon bu modelde çalışmamaktadır.)
  • Page 18 Timer On Timer off Timer On Timer off Confirm/Cancel Confirm/Cancel...
  • Page 19 ç ünite Birim Kurulumu Kurulum için Gerekli Araçlar Güç Kayna � Tornavida Tork anahtar� Fi i prize takmadan önce voltaj� hatas�z kontrol edin. Kesici (17mm,22mm,26mm) Güç kayna � ilgili isim plakas�n�n ki ile ayn�d�r. Demir testeresi Boru kesici Özel bir güç devresi kablosu kurun. Delik karot matkab�...
  • Page 20 Bükme esnasında, boruları A=130mm C=110mm ezmemeye dikkat edin. ESA1309A100 ç/dı elektrik kablosunu ba lamadan önce ba layın, ve sonra ba lanmı A=120mm C=80mm olanı özellikle ba lantı parçasının ısı yalıtımına çekin.
  • Page 21 ç ünite kurulumundan önce kabloyu ba larken 7 Drenajda dikkat edilmesi gerekenler Kabloyu ünitenin arka tarafından takın, sonra ön taraftan dı arı çekin. Lütfen drenaj hortumlarını a a ı yönde hatasız ekilde koyunuz. Vidaları gev etin ve kablo uçlarını tamamen terminal blo u içine takın, Lütfen a a ıda gösterildi i gibi drenaj yapmayınız.
  • Page 22 Bakım Klimanın Akıllı Kullanımı için Uygun oda sıcaklı ı ayarı Hava giri ve çıkı ı engellemeyin Uzaktan kumanda ç Ünite Uygun sıcaklık Klimayı kuru ve yumu ak bir bez ile temizleyin. Ciddi lekeler için su Su kullanmayın, kontrolörü bir ile seyreltilmi bir nötr deterjan kuru bez ile silin.
  • Page 23 Dikkat! UYARI Kurulum için Lütfen Yetkili Servisi arayınız. Uygunsuz çalı manın elektrik oku, yangın, su sızıntısına neden olması nedeniyle lütfen klimayı lütfen kendiniz kurmayınız. UYARI Yanık-küçük bulgu gibi anormallik oldu unda, derhal Bir devre kesicili özel bir güç kayna ı Drenajın uygun kurulumunu güvenli ekilde kontrol operasyon butonunu durdurun ve yetkili birim ile irtibat kullanın.
  • Page 24 Dikkat Sorun Giderme Klimanın havalandırma ızgarasını engellemeyin veya kapatmayın. Servise danı madan önce, a a ıdaki listeyi kontrol edin. Parma ınızı veya herhangi bir di er bir eyleri giri /çıkı ve salınım hava deli ine koymayın. Bu ürün algılamaya yada zihinsel yetene e sahip olanlar (çocuklar Olgu Neden veya kontrol noktaları...