Operating instructions
·
·
·

1. SAFETY REGULATIONS AND INFORMATION

Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1

1.1 Hazard levels for warnings

1
1
These operating instructions use the following hazard levels to indicate
1
potentially hazardous situations and important safety regulations:
1
DANGER
2
Indicates an imminently hazardous situation which will result in
2
death or serious injury if the specified actions are not taken.
2
Compliance with the instructions is imperative.
2
WARNING
2
Indicates a potentially hazardous situation which can result in
2
death or serious injury if the specified actions are not taken.
2
Exercise extreme caution while working.
3
CAUTION
Indicates a potentially hazardous situation which can result in
4
minor or moderate injury or damage to property if the specified
4
actions are not taken.
5
5
NOTE
5
A potentially harmful situation can occur and, if not avoided, can
5
lead to property damage.
5

1.2 Staff qualifications

6
The device may only be transported, unpacked, installed, operated,
6
maintained and otherwise used by suitably qualified, trained and
6
authorized technical staff.
6
Only authorized specialists are permitted to install the device, to carry
8
out a test run and to perform work on the electrical installation.
9
9

1.3 Basic safety rules

9
The safety hazards associated with the device must be assessed again
9
following installation in the final product.
The locally applicable industrial safety regulations are always to be
9
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
10
increases the risk of accidents.
10
Note the following when working on the device:
10
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.

1.4 Voltage

; Check the device's electrical equipment at regular intervals; see
Chapter 6.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.
·
·
·

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S1G300-CA19-02 and is the answer not in the manual?

Questions and answers

Summary of Contents for ebm-papst S1G300-CA19-02

  • Page 1: Table Of Contents

    Note the following when working on the device: 6.3 Disposal ; Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage ; Check the device's electrical equipment at regular intervals; see Chapter 6.2 Safety inspection.
  • Page 2: Safety And Protective Features

    Operating instructions S1G300-CA19-02 WARNING WARNING Live terminals and connections even with device Rotating device switched off Long hair and dangling items of clothing, jewelry and the like Electric shock can become entangled and be pulled into the device. Injuries can result.
  • Page 3: Intended Use

    Operating instructions S1G300-CA19-02 2. INTENDED USE The device is exclusively designed as a built-in device for conveying air according to its technical data. Any other usage above and beyond this does not conform with the intended purpose and constitutes misuse of the device.
  • Page 4: Technical Data

    Operating instructions S1G300-CA19-02 3. TECHNICAL DATA 3.1 Product drawing All dimensions in mm. Direction of air flow "A" Cable AWG20; 3x crimped splices Item no. 50091-5-9970 · ENU · Change 205631 · Approved 2019-07-26 · Page 4 / 11 ·...
  • Page 5: Nominal Data

    With regard to cyclic speed loads, note that the rotating parts of the device are designed for a maximum of one million load Motor M1G055-BI cycles. If you have special questions, consult ebm-papst for support. Phase ; Use the device in accordance with its degree of protection.
  • Page 6: Connection And Startup

    Operating instructions S1G300-CA19-02 4. CONNECTION AND STARTUP Only connect the device to circuits that can be switched off with an all-pole disconnection switch. 4.1 Mechanical connection 4.2.1 Requirements CAUTION ; Check whether the information on the nameplate matches the Cutting and crushing hazard when removing fan from connection data.
  • Page 7 Operating instructions S1G300-CA19-02 Fig. 2: Cable routing for fans installed upright. The cables must always be routed downward. NOTE Cable routing is to be performed accordingly if use is made of the ESM plug-in module to connect the fan. Item no. 50091-5-9970 · ENU · Change 205631 · Approved 2019-07-26 · Page 7 / 11 ·...
  • Page 8: Connection Diagram

    Operating instructions S1G300-CA19-02 4.4 Connection diagram Drawing preliminary! Item no. 50091-5-9970 · ENU · Change 205631 · Approved 2019-07-26 · Page 8 / 11 · · · · · ·...
  • Page 9: Checking Connections

    Operating instructions S1G300-CA19-02 4.5 Checking connections 5. INTEGRATED PROTECTIVE FEATURES ; Ensure isolation from supply (all phases). The integrated protective functions cause the motor to switch off automatically in the event of the faults described in the table. ; Make sure a restart is impossible ;...
  • Page 10: Cleaning

    Let the device protection 6 months replacement of cool down. cover for device intactness or In the event of further malfunctions, contact ebm-papst. damage Device for Visual inspection At least every Replacement of damage to 6 months device blades and 6.1 Cleaning...
  • Page 11 ● Dispose of electronic components employing the proper procedures for electronic scrap. → Please contact ebm-papst for any other questions on disposal. Item no. 50091-5-9970 · ENU · Change 205631 · Approved 2019-07-26 · Page 11 / 11 · ·...