versa CSG300 Series Manual

versa CSG300 Series Manual

Cloud services gateway
Hide thumbs Also See for CSG300 Series:

Advertisement

At a Glance
The Versa Cloud Services Gateway (CSG) 300 series appliances deliver highly secure site-to-site data connectivity to
small businesses and to home offices.
These appliances provide the following features:
• Single hardware platform that supports different CPUs and memory sizes
• Management Ethernet ports with dual use and dedicated options:
• One RJ45 RS232 console port
• One USB 2.0 management port for plugging in external LTE or WiFi modems
• One Cu GE dual purpose port for data and management
• MDI and MDIX autoswitchable EoC ports
• PoE source support on four Ethernet ports with NIC module add-on
• Wireless options:
• CSG350–Two built-in wireless slots
• CSG355 and CSG365–Three dedicated built-in wireless slots to support LTE
• External AC power supply
• Fan-based cooling
• Desktop or ceiling mount, rack-mountable in a 19" rack
CSG300 Appliance Models
The CSG300 appliances are available in the following models:
• CSG350—Compact and optimized appliance for deployment in small branches (up to 75 users) that require
advanced application and cloud intelligence with hierarchical QoS, providing a cost-effective SD-WAN solution.
• CSG355–Powerful appliance perfect for deployment in both small- and medium-sized branches that need
advanced SD-Security (NGFW and UTM) along with comprehensive advanced application and cloud-intelligent
SD-WANservices on-premises.
• CSG365—High performance, powerful appliance for deployment at a medium-sized branch locations that
require advanced application and cloud-intelligent SD-WAN services, advanced SD-Security (NGFW and UTM).
The CSG300 appliance models provide the following CPU, memory, and storage sizes. See Table 1.
Table 1: CSG300 Appliance Models
https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Overview/At_a_Glance
Updated: Tue, 31 Mar 2020 19:09:37 GMT
Powered by
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CSG300 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for versa CSG300 Series

  • Page 1 At a Glance The Versa Cloud Services Gateway (CSG) 300 series appliances deliver highly secure site-to-site data connectivity to small businesses and to home offices. These appliances provide the following features: • Single hardware platform that supports different CPUs and memory sizes •...
  • Page 2: Chassis Views

    Figure 3 and Figure 4 show the front and rear panels of the CSG355. The panels for the CSG355 and CSG365 appliances are identical. Figure 3: Front Panel of the CSG355 Appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Overview/At_a_Glance Updated: Tue, 31 Mar 2020 19:09:37 GMT Powered by...
  • Page 3 Figure 4: Rear Panel of the CSG355 Appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Overview/At_a_Glance Updated: Tue, 31 Mar 2020 19:09:37 GMT Powered by...
  • Page 4: Chassis Specifications

    CSG300 Series Appliance Specifications A CSG300 series appliance chassis is made of aluminum for optimal heat dissipation. This article lists the chassis and regulatory compliance specifications for the CSG300 series appliance. It also lists certifications and export control classification numbers (ECCNs) for the appliance.
  • Page 5 20 to 70°C (68 to 158°F) at sea level Humidity 10 to 85% relative humidity Reliability MTBF Minimum of 70,000 hours CSG355 and CSG365 Appliance Table 2 lists the specifications for a CSG355 and CSG365 appliance chassis. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG… Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by...
  • Page 6 Table 2: CSG355 and CSG365 Chassis Specifications https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG… Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by...
  • Page 7 Chassis depth 6.7” (172 mm) Rack height 1 RU Chassis weight Chassis weight with installation kit: 2.5 kg maximum Package Specifications Package height 7" (17.78 cm) Package width 16.7" (42.4 cm) https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG… Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by...
  • Page 8: Regulatory Compliance

    Humidity 10 to 85% relative humidity Reliability MTBF Minimum of 70,000 hours Regulatory Compliance Table 2 lists the regulatory compliance specifications for a CSG300 series chassis. Table 2: CSG300 Series Regulatory Compliance Specifications Item Specification Safety CE Marketing TPM 2.0...
  • Page 9 Certifications A CSG300 series appliance complies with the certificates listed in Table 3. Table 3: CSG300 Series Certifications Region Certifications ¥ EN 300 328 (Bluetooth) ¥ EN 301 489-1 ¥ EN 301 489-17 (Bluetooth) Europe ¥ EN 50385 MPE(SAR Evaluation) ¥...
  • Page 10 CCATS Use of item Item ECCN Number Number Number by Versa appliance https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/01_CSG… Updated: Tue, 31 Mar 2020 17:58:46 GMT Powered by...
  • Page 11: Front And Rear Panel Components

    Front and Rear Panel Components This article describes the front and rear panel components of a CSG300 series appliance. For the exact location of these components on the appliance, see At a Glance. Front Panel The front panel of a CSG300 series appliance has two status LEDs.
  • Page 12: Sim Card Slots

    SIM Card Slots The rear panel of a CSG300 series appliance has two nano-SIM card slots. If you subscribe to a single wireless service, use the SIM 1 slot to install the LTE device. If you are subscribing to dual wireless service, use both the SIM 1 and SIM 2 slots to activate the LTE devices.
  • Page 13: Reset Button

    Reset Button The Reset button on the rear panel of a CSG300 series appliance resets the appliance. The reset functionality depends on the number of times you press it, as described in Table 3. The Reset button is recessed so that it is not accidentally pressed while the appliance is operational.
  • Page 14 LTE Modem Module The CSG300 series LTE modem module is a high-performance Cat-6 LTE Advanced modem that provides up to 300 Mbps download speeds and 50 Mbps upload speeds. The LTE modem supports multiple carriers, and it has been certified by major global carriers. The appliance has two externally accessible SIM card slots, one for each embedded LTE-A modem.
  • Page 15 Vodafone, US Cellular, Anatel You can order CSG300 series appliances with an optional LTE modem module. The LTE modem modules have either one SIM slot or two SIM slots. For modules with one SIM slot, you insert the SIM card into the SIM1 slot, which is on the front of the appliance.
  • Page 16: Wireless Options

    CSG365 appliances have three internal wireless slots. The CSG300 series appliances have one WiFi Access Point (AP) module. The WiFi AP module is a dual-band module that simultaneously supports 2.4 GHz, for longer distances, and 5 GHz, for faster throughput. It provides the following WiFi capabilities: •...
  • Page 17: Interface Numbering

    Figure 1: Port-to-VNI Mapping - CSG350 Figure 2 shows port-to-VNI mapping for the CSG355 and CSG365. Note that the CSG355 and CSG365 chassis are identical. Figure 2: Port-to-VNI Mapping - CSG355 and CSG365 https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Components_and_Specifications/06_Interf… Updated: Wed, 01 Apr 2020 18:55:33 GMT Powered by...
  • Page 18: Airflow Requirements

    When placing a CSG300 series appliance on a desk, ensure that the vents on the side of the unit are never blocked, to allow hot air to flow out of the appliance. Covering the vents prevents heat from dissipating out of the appliance, which will cause the chassis to overheat and then shut down.
  • Page 19: General Safety Guidelines

    Installation Guidelines This article provides general safety standards and warnings relating to installing or connecting a CSG300 series appliance. General Safety Guidelines Caution: Before installing or removing a CSG300 series appliance, ensure that the appliance chassis is electrically connected to ground. When you are installing or removing an appliance, ensure that you wear an ESD grounding wrist strap.
  • Page 20 20 cm between the radiator and your body. Operation of this equipment in a residential environment could cause radio interference. Operation of this equipment is for indoor use only. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/01_Installation_… Updated: Wed, 01 Apr 2020 18:57:04 GMT Powered by...
  • Page 21: Site Preparation Guidelines

    • High humidity conditions can cause moisture to penetrate into the chassis. The appliance can operate in relative humidity of 10% to 85%, non-condensing. Rack Requirements You can mount a CSG300 series appliance in a 19-inch four-post rack using slide rails. Table 1 lists the rack requirements. Table 1: Rack Requirements for a CSG300 Series Appliance...
  • Page 22 When planning your site for installing a CSG300 series appliance in a 19-inch rack or on a desk, ensure that the vents on the side of the unit are never blocked, to allow hot air to flow out of the appliance. Covering the vents prevents heat from dissipating out of the appliance, which will cause the chassis to overheat and then shut down.
  • Page 23 Unpack a CSG300 Series Appliance The CSG300 series appliance is packed in a plastic box, and it is shipped in a cardboard carton, secured with foam packing material. The carton also contains an accessory box. It is recommended that you unpack the appliance only when you are ready to install it.
  • Page 24 See Return Hardware. Packing List for a CSG300 Series Appliance The cardboard carton in which a CSG300 series appliance is shipped contains a packing list. Check the packing list against the parts that you receive in the shipping carton.
  • Page 25 4—#12-24, 12.7 mm Torque: 3.2+/-0.05 N.M. Mount a CSG300 Series Appliance in a Rack You can mount a CSG300 series appliance in a four-post 19-inch rack. Two people are required to mount the appliance. To mount the appliance, ensure that you have the following tools: •...
  • Page 26 Use four screws to attach each mounting ear. Figure 3: Attach the Mounting Ears to a CSG300 Series Appliance 5. Grasp both sides of the appliance chassis, making sure that the front of the chassis is facing you.
  • Page 27 Updated: Wed, 01 Apr 2020 19:02:26 GMT Powered by...
  • Page 28 Connect a CSG300 Series Appliance This article describes how to connect a CSG300 series appliance to an AC power source and to a management console. Step 1: Connect Earth Ground to a CSG300 Series Appliance To ensure proper operation of a CSG300 series appliance and to meet safety and electromagnetic interference (EMI) requirements, you must connect the appliance to earth ground before you connect power to the appliance.
  • Page 29 1. Plug one end of the console cable into the console port located on the rear panel of the CSG300 series appliance. 2. Plug the other end of the cable into the console server or into a management console. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Planning_and_Installation/04_Connect_a_…...
  • Page 30: Return Hardware

    Locate the Model and Serial Number To return a CSG series appliance to Versa Networks, you need the model and serial number of the appliance. These numbers are printed on the shipping box and on the unit label located on the bottom of the appliance.
  • Page 31 6. Close the cardboard carton and seal it with packing tape. 7. Write the RMA number on the shipping label or on the outside of the box for tracking purposes. https://docs.versa-networks.com/Hardware/Cloud_Services_Gateway_300_Series/Maintenance/Return_Hardware Updated: Wed, 01 Apr 2020 18:58:08 GMT Powered by...

This manual is also suitable for:

Csg350Csg355Csg365

Table of Contents