On-board computer
Table of Contents

Advertisement

Settings
Mode 1
Activate the functions of the on-board computer
Code 1
Code 2
Mode 2
Number of track marker sensors
Code 0
Code 1
Code
2 to 99
Mode 3
Machine type
Code 0
Code 1
Code 2
Mode 4
The period between occurrence of the error in tramline control and triggering of the
alarm.
Code 00
Code 10
Code 22
Mode 5
The period in which no alarm must be triggered
for cam wheel seed drills
between the command to create tramlines and standstill of the lay shaft
for pneum. seed drills
between the command to create tramlines closing of the outlets in the distributor
head.
Code 00
Code 10
Code 22
Modus 6
Rotary cultivator monitoring
Code 0
Code 1
Fig. 15
22
Activate all functions of the on-board computer
Activate only the hectare counter of the on-board computer
Machines with 2 track marker sensors,
e.g. front tank drill combination
with 2 track marker sensors (see Fig. 16).
Machines with 1 track marker sensor
on hydraulic valve (see Fig. 17)
on control mechanism (see Fig. 18).
Machines without track marker and
without track marker sensors [see note Fig. 19, on page 23)].
Cam wheel seed drill
Pneumatic seed drill
Direct seed drill Primera
Alarm switched off (factory setting)
Setting for pneumatic seed drills (10 seconds)
Setting for cam wheel seed drills (22 seconds)
Do not make this setting (0 seconds)
Setting for pneumatic seed drills (10 seconds)
Setting for cam wheel seed drills (22 seconds)
Setting without rotary cultivator monitoring
Setting with rotary cultivator monitoring