The Veeder-Root brand C346 family offers a new level of performance in a 1/16 DIN
instrument. Fully programmable to operate as a preset counter, a rate meter (with
outputs) or an elapsed time counter. Enhanced fuctionality provides operating
modes for batching, background totalizing, and operation as dual counters with
master sum. When used as an elapsed time counter, the C346 offers unique
functionality for measurement of pulse widths or time between pulses. The C346 is
available with an LCD display or the industry's only 6 digit LED display for a 48mm
x 48mm product.
A wide variety of features are present that enable use in even the most demanding
applications. Inputs can be accepted from both NPN or PNP sensors, dry contacts or
encoders, and the input scaling function enables rate and count inputs to be
displayed in engineering units. Single and dual preset models are available and
each preset offers both a transistor output, which can interface to an external SSR
or PLC, and a relay output for
directly driving a load. The outputs
can be programmed for latching or
timed operation.
Even with a high level of
functionality, simplicity of operation
is still maintained. Important
parameters such as the preset and
prescale values can be called up
quickly with direct access keys
while an intuitive button per digit
interface enables those values to be changed easily.
The C346 has a NEMA 4 rated faceplate is CE approved, and UL and CUL listed.
Features
• Choice of 6 digit LED or LCD Display
• Button Per-Digit setting and direct access
keys for easy opertation
• Field programmable for operation as a
preset counter, batch counter, rate meter
or elapsed time meter, all with outputs
• Input scale function for display in
engineering units
• Add/Subtract, Add/Add and quadrature
input modes
• Background count value keeps track of
production totals
• 12 - 24 VDC sensor power supply
• Accepts either NPN or PNP inputs
• Relay and transistor outputs for each
preset
• Reset via front panel, remote input or
automatically
• NEMA 4 rated front panel
Index
Overview
page 2
page 2
page 3
page 4
page 4
page 5
page 8
page 8
page 11
page 13
page 16
page 17
General
page 19
page 20
page 20
Technical Manual
701996-0000
Veeder-Root
brand
C346
Preset Counter
Rate Meter
Time Counter

Advertisement

Table of Contents
loading

Summary of Contents for Danaher Veeder-Root C346 Series

  • Page 1: Table Of Contents

    Introduction The Veeder-Root brand C346 family offers a new level of performance in a 1/16 DIN instrument. Fully programmable to operate as a preset counter, a rate meter (with outputs) or an elapsed time counter. Enhanced fuctionality provides operating modes for batching, background totalizing, and operation as dual counters with master sum.
  • Page 2: Construction

    O V E R V I E W P R O G R A M M I N G CONSTRUCTION Compact Design Standard 1/16 DIN (48mm x 48mm) faceplate VEEDER-ROOT Main Display Can be toggled quickly between count value, set value and 346421 prescale value.
  • Page 3: Panel Mounting

    PANEL MOUNTING Panel Cutout Dimensions VEEDER-ROOT 123456 48mm 45mm 45mm 48mm 93mm Make cutout(s) based on the recommended panel opening Top Mounting illustrated in the drawing above. Grooves Place the unit in the panel and slide the included gasket over the rear of the unit. Make sure the unit is positioned squarely against the panel and the gasket is not distorted.
  • Page 4: Operation

    O P E R A T I O N P R O G R A M M I N G FRONT PANEL LCD Version LED Version VEEDER-ROOT VEEDER-ROOT 346421 346421 1. Main Display 2. Status Displays 3. Edit Key 4. Numeric Keys 1.
  • Page 5: Operation Mode

    In Operation Mode, the default display is the Count Value. The OPERATION Presets and Prescale Value can be accessed by simultaneously pressing the Edit key and the appropriate Numeric key. The Numeric keys are then used to alter the value. It is necessary to then press the Edit key to confirm the change and return to the COUNT MODE OPERATION Count Value display...
  • Page 6 O P E R A T I O N P R O G R A M M I N G TIME MODE OPERATION 1 2 3 4 5 6 Edit Preset 1 Edit Preset 2 Background or Batch Total 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 F1 F2...
  • Page 7 BATCH MODE OPERATION 1 2 3 4 5 6 Edit Preset 1 Edit Prescaler Edit Preset 2 Batch Total 1 2 3 4 5 6 1 2 3 4 5 6 0 0 0 1 2 3 4 5 6 F1 F2 Return to Count Value Change Value...
  • Page 8: Programming

    P R O G R A M M I N G The C346 can be programmed in the field to operate as a Preset Counter, a Rate Meter, BASIC FUNCTIONALITY Elapsed Time Counter, Dual Register or Batch Counter. The default is Preset Counter. To change the function hold down the both the Edit key and the "6"...
  • Page 9 F7 Output 2 Time: Sets the amount of time Output 2 will be active after the Preset is reached. Choices are the same as Output 1 F9 Output on Reset: When set to ON (1), the primary output (Output 2 on dual preset version) will .
  • Page 10 P R O G R A M M I N G F21 Preset 1 Access Enable: When active (0), the Preset 1 value can be accessed by simultaneously holding down the Edit key and the "1" key. If set to inactive (1), Preset 1 can not be accessed, or only accessed by holding down the Edit key and the "1"...
  • Page 11: Rate Meter Mode

    If the functionality has been set to FN1, then the unit will operate as a RATE METER PROGRAMMING programmable rate meter utilizing a time interval (1/Tau) method. To enter the Program mode, hold down the Edit key and the "5" key during power-up.
  • Page 12 P R O G R A M M I N G F10 Input Type: Enables the unit to be programmed to work with either sinking or sourcing inputs. Choices are NPN (0), and PNP (1). F11 Count Speed: Enables the unit to be set for full speed of 5 kHz (1) or to 30 Hz (0) to provide debounce filtering for contact inputs.
  • Page 13: Elapsed Time Mode

    If the functionality has been set to FN2, then the unit will operate as an ELAPSED TIME MODE elapsed time counter, in one of 3 programmable operation modes. To enter the Program mode, hold down the Edit key and the "5" key during power-up.
  • Page 14 P R O G R A M M I N G F9 Output on Reset: When set to ON (1), the primary output (Output 2 on dual preset version) will . 1 0 activate when the unit is reset. F10 Input Type: Enables the unit to be programmed to work with either sinking or sourcing inputs. .
  • Page 15 F22 Preset 2 Enable: When active (0), the Preset 2 value can be accessed by simultaneously holding down the Edit key and the "2" key. If set to inactive (1), Preset 2 can not be accessed, or only accessed by holding down the Edit key and the "2"...
  • Page 16: Dual Register Mode

    P R O G R A M M I N G If the functionality has been set to FN3, then the unit will operate as a DUAL REGISTER MODE totalizer with seperate subtotal registers for input A and input B. To enter the Program mode, hold down the Edit key and the "5"...
  • Page 17: Batch Counter Mode

    F21 Reserved F22 Reserved F23 Prescale Access Enable: When active (0), the Prescale value can be accessed by simultaneously holding down the Edit key and the "3" key. If set to inactive (1), Prescale can not be accessed, or only accessed by holding down the Edit key and the "3"...
  • Page 18 P R O G R A M M I N G F4 Reset Operation: Defines how the count value will behave when the preset is reached. Choices are: Reset to "0", no Autoreset Reset to "0", Autoreset Reset to Preset, no Autoreset Reset to Preset, Autoreset F6 Output 1 Time: Sets the amount of time Output 1 will be active once the Preset is reached.
  • Page 19: Specifications

    F21 Preset 1 Enable: When active (0), the Preset 1 value can be accessed by simultaneously holding down the Edit key and the "1' key. If set to inactive (1), Preset 1 can not be accessed, or only accessed by holding down the Edit key and the "1"...
  • Page 20: Ordering Information

    NOT LIMITED TO ANY WARRANTY OF able to obtain from the supplier thereof. No MERCHANTABILITY OR OF FITNESS FOR A products shall be returned to the Company PARTICULAR PURPOSE. Danaher Controls Printed in U.S.A. 1675 Delany Road #701996-0000 Gurnee, IL 60031–1282 January 1996 Phone: 847.662.2666...